7 floors · 132 apartments · 41,857 sq ft · built 1901 · class D7 · owner of record: Washington Heights Etc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 9 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 47 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 47 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 47 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 63 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 41,857 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 168 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 168 days | Annual filing |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 291 days | Registered through 2027-09-01 |
| Facade inspection report (Cycle 10B) Applies Local Law 11 / FISP · Feb 21, 2026 to Feb 21, 2028 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 0, 7 or 8 are in sub-cycle 10B. DOB facade records for this building show $2,070,000 in late-filing or failure-to-file penalties. Agency page | Feb 21, 2028 in 464 days | No Cycle 10 report on record yet |
| Annual boiler inspection (2 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-05-19 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Nov 6, 2026 | Construction CLASS - 2 OBSERVED SIDE WALK SHED UNDER ACTIVE PERMIT # M00638361-I1-SH AFFIXED AT THE WRONG LOCATION AND NOT IN COMPLIANCE AS PER CODE, THIS ALSO IS CAUSING OBSTRUCTION TO PUBLIC VIEW OF STREET SIGNS AT THE INTERSECTION #39210968K | Jan 14, 2027 PENDING | $1,250 |
| Nov 6, 2026 | Construction CLASS - 2 OBSERVED PIPE SCAFFOLD INSTALLED IS NOT CONFORMING TO APPROVED PLANS UNDER JOB # M01284330-I1-SH, DUE TO THE SECTION ON SWS IS NOT INDICATED ON PLANS., CONFORM WORK TO APPROVED CONSTRUCTION DOCUMENTS/AMENDMENTS #39210969M | Jan 14, 2027 PENDING | $2,500 |
| Sep 10, 2026 | Construction CLASS - 2 AT TIME OF INSPECTION, OBSERVED 7-STORY BUILDING WITH SIDEWALK SHED AT EXPOSURES 1, 2, AND 4 AND SCAFFOLD AT EXPOSURE 3 NOT MAINTAINED. NETTING WAS MISSING AT THE CORNER OF EXPOSURES 2 AND 3. EXPOSED PLANKS, A #39558991X | Nov 19, 2026 PENDING | $2,400 |
| Aug 14, 2026 | Construction CLASS - 2 OBSERVED AT TIME OF INSPECTION GAS PIPING WAS REROUTING FROM PRE-EXISTING KITCHEN IN BASEMENT TO SUPPLY 2 COMMERCIAL FRYER AND GRILL IN FIRST FLOOR DELI . NO PERMIT ON FILE WITH DEPARTMENT OF BUILDINGS., OBTAIN #39200686N | Oct 22, 2026 DEFAULT | $1,280 |
| Aug 14, 2026 | Construction CLASS - 2 OBSERVED AT TIME OF INSPECTION, GAS PIPING WAS INSTALLED WITH PROHIBITED UNION AND COUPLING.AS PER FGC 403.10.1.1 UNIONS AND CLOSE NIPPLE SHALL BE PROHIBITED., REPAIR AND/OR REPLACE #39200685L | Oct 22, 2026 DEFAULT | $1,280 |
| Jul 6, 2026 | Elevators CLASS - 1 VF... CEASE USED... D L M NOT WORKING...42.X.10....DOOR POSITION MONITORING INOPREARIVE . THIS CONTROLLER FEATURE WHICH ENSURE PASSENGERS SAFETY , CONTACR DOB DEVICE RETURN TO SERVICE.. OIL LEAKING ON MACHINE C #39194798J | Sep 10, 2026 DEFAULT | $6,250 |
| May 15, 2026 | Construction CLASS - 2 REMOVAL OF SAFETY MEASURES WITHOUT DEPARTMENT APPROVAL. NOTE: AT TIME OF INSPECTION I OBSERVED NO PROTECTION/SHED AT EXPOSURE #1 WEST ELEVATION. REMEDY: COMPLY WITH RULE. #35729683M | Jul 23, 2026 DEFAULT | $6,250 |
| May 15, 2026 | Construction CLASS - 1 FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE AND APPURTENANCES. NOTE: AT TIME OF INSPECTION, I OBSERVED CRACKED MASONRY/CRACKED BRICK/DETERIORATED MORTAR JOINTS/SPALLING MASONRY AT MULTIPLE LOCATIONS AT EXPOSUR #35729682K | Jul 23, 2026 DEFAULT | $25,000 |
| May 12, 2026 | Construction CLASS - 2 AT TIME OF INSPECTION OF 7 STORY MIXED USE BUILDING WITH SIDEWALK SHED IN PLACE WITHOUT INFORMATION PANEL ON PARAPET CAUSING HAZAROUS CONDITIONS.PROVIDE SIGN #39554020P | Jul 16, 2026 DEFAULT | $6,250 |
| May 12, 2026 | Construction CLASS - 2 TIME OF INSPECTION OF A 7 STORIES BUILDING I OBSERVED SIDEWALK INSTALLED ON EXPOSURE # 2 WITH FALLEN AND DETERIORATE PARAPET PANEL ON IT, THIS WILL ALLOW DEBRIS FALLEN INTO THE STREET 3307.6.4.6, ALSO OBSERVED #39554019H | Jul 16, 2026 DEFAULT | $10,000 |
| Apr 30, 2026 | Construction CLASS - 2 PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATIONS. AS NOTED: AT THE TIME OF INSPECTION I OBSERVED ON SIDEWALK SHED DEFECTIVE, LOOSE PARAPET PANELS; MISSING PANELS; ROTTED MUD SILLS ON THE SOUTHERN END OF #35726812X | Jun 29, 2026 DEFAULT | $5,000 |
| Mar 31, 2026 | Construction CLASS - 2 TIME OF INSPECTION OF A 7 STORIES BUILDING I OBSERVED SIDEWALK INSTALLED ON EXPOSURE # 2 WITH FALLEN AND DETERIORATE PARAPET PANEL ON IT, THIS WILL ALLOW DEBRIS FALLEN INTO THE STREET 3307.6.4.6, ALSO OBSERVE #39552474K | Jun 11, 2026 DEFAULT | $10,000 |
| Mar 31, 2026 | Construction CLASS - 2 AT TIME OF INSPECTON I OBSERVED SIDEWALK SHED INSTALLED ON EXPOSURE # 2 WITHOUT SIGNS OR PROJECT INFORMATION PANEL ON THE SHED PARAPET, TO DISPLAY THE NAME AND THE CONTACT INFORMATION OF THE OWNER OR THE GENERA #39552475M | Jun 11, 2026 DEFAULT | $6,250 |
| Oct 24, 2025 | Construction CLASS - 2 AT TIME OF INSPECTION OF 7 STORY BUILDING OBSERVED SIDEWALK SHED IN PLACE FOR FACADE WORK NOT MAINTAINED PER CODE 1. STEEL MEMBERS PASSED 18" FROM CURB LINE 2. ROTTING/ DETERIORATING MUDSILLS CAUSING HAZARDOUS #39546313Z | Jan 8, 2026 ADMIT/IN-VIO | $0 |
| Jun 15, 2023 | Elevators CLASS - 2 EMERGENCY PHONE IN ELEVATOR NOT WORKING;REPAIR;PROVIDE CAT 5 TAGS ON CONTROLLER #39088649R | Aug 24, 2023 DEFAULT | $0 |
| Oct 19, 2022 | Local Law CLASS - 2 FAILURE TO SUBMIT ACCEPTABLE REQUIRED CYCLE 7B & 8B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL & APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL #806971.AGG2:HISTORY OF NONCOMPLIANCE O #37022759N | Feb 2, 2023 DEFAULT | $0 |
| Dec 2, 2021 | Elevators CLASS - 2 HOIST ROPES RUSTING AND ROUGING, PHONE NOT WORKING #39052149X | Mar 17, 2022 DEFAULT | $0 |
| Oct 8, 2021 | Local Law CLASS - 2 FAILURE TO FILE ACCEPTABLE AMENDED CYCLE 6 REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL FACADES REPORT REQUIRED B Y 28-302.5 FOR CONTROL#606971. REMEDY: FILE ACCEPTABLE REPORT. #37022233Z | Mar 3, 2022 DEFAULT | $0 |
| Jun 1, 2021 | Local Law CLASS - 2 FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYFLE 7B AND 8B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPURTERNCES REQUIREDBY 28-302.4 FOR CONTROL #8066971. AGG2 HISTORY OF NONCOMPL #37021347M | Jan 13, 2022 DEFAULT | $0 |
| Jun 24, 2020 | Elevators CLASS - 1 NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC. THIS IS A CONTROLLER FEATURE WHICH ENSURES PASSENGER SAFETY. REMEDY; FILE APPLICATION, INSTALL DLM A #39024494Z | Dec 2, 2021 IN VIOLATION | $0 |
| May 20, 2020 | Local Law CLASS - 2 FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 7B AND 8B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL#806971.AGG2 HISTORY OF NONCOMPLI #37018966Y | Jun 10, 2021 ADMIT/IN-VIO | $0 |
| Oct 15, 2018 | Local Law CLASS - 2 FAILURE TO SUBMIT A REQUIRED CYCLE 8B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL #806971. AGG2 HISTORY OF NONCOMPLIANCE ON 3700108 #37012751J | May 23, 2019 DEFAULT | $0 |
| Aug 8, 2018 | Elevators CLASS - 2 2X10,59BB7,60L10. 2X10-OUTSIDE COMM INOPERATIVE REPAIR; 59BB7-BRAKE TAG EXPIRED PROVIDE; 60L10-MACHINE ROOM LIGHTING DEFECTIVE REPAIR. #38264628L | Nov 15, 2018 DEFAULT | $0 |
| Aug 12, 2017 | Construction CLASS - 2 FAILURE TO COMPLY W/ COMM'S ORDER TO FILE A CERT OF CORRECTION W/ DOB FOR ECB VIO#35138164X. WHICH WAS ISSUED ON 2/8/17 FOR WORK W/O A PERMIT ON 6TH FL.REM FILE CERT OF CORRECTION W/ DOB #35249357Y | Sep 28, 2017 DEFAULT | $0 |
| Feb 14, 2017 | Elevators CLASS - 2 7L10,3D6,29J1,16M7,67L10,56Y2,56Y13. 7L10-DOOR RESTRICTOR DEFECTIVE REPAIR; 3D6-CAR ENCLOSURE UNSECURED PROPERLY SECURE; 29J1-DOOR OPERTOR MISALIGNED ADJUST; 14M7-CAR MIRROR MISSING PROVIDE; 62L10-COMMUNICATI #38253195L | Apr 6, 2017 DEFAULT | $0 |
| Feb 8, 2017 | Construction CLASS - 2 WORK WITHOUT A PERMIT.NOTED; AT TIME OF INSPECTION OBSERVED ON 6FLR SOUTHSIDE EXISTING KITCHEB WAS REMOVED,ERECTED FULL HEIGHT PARTITION WALL AND CREATED ON EXTRA OFFICE SPACE FOR(NEW BEGINNING PROGRAM)REM:OBTA #35138164X | Apr 6, 2017 STIPULATION/IN-VIO | $0 |
| Feb 8, 2017 | Construction CLASS - 2 FAILURE TO MAINTAIN BLDG CODE COMPLIANT MANNER NOTED:AT TIME OF INSPECTION OBSERVED FEW SPRINKLER HEADS CAPS TO BE PAINTED AT DIFFERENT FLRSOBSERVED FEW ON 1ST FLR BY THE ELEVATOR,3RD FLR AND SOUTHSIDE OF 7TH F #35138162M | Apr 6, 2017 STIPULATION/IN-VIO | $0 |
| Feb 8, 2017 | Construction CLASS - 3 OCCUPANCY CONTRAR TO THAT ALLOWED BY THE CERTIFICATE OF OCCUPANCY OR BY BLDG DEPT RECORDS;AT TIME OF INSPECTION ON 6TH FLR OBSERVED "2"OFFICES CONTRARY TO C OF O#108790 ISSUED ON 02/06/1996 WHICH INDICATES ONLY #35138163Y | Apr 6, 2017 STIPULATION/IN-VIO | $0 |
| Jan 19, 2017 | Construction CLASS - 2 FAILURE TO MAINTAIN EXTERIOR BLDG GENERAL NOTES: A/C UNITS MISSING BRACKETS GROUND FLR REAR EGRESS DOOR NOT OPERATIVE WEST ELEV EXP OBJECTS ON SILL 5TH FLR.NORTH ELEV EXP2 OPEN ELEC BOX, SOUTH ELEV EXP 4-1 FL #35210310Z | Jul 13, 2017 DEFAULT | $0 |
| Nov 7, 2016 | Local Law CLASS - 2 FAILURE TO FILE ACCEPTABLE AMENDED REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL LOCAL LAW 11/98 REPORT. AGG1 PRIORNOV 36027857N UNDER 28-302.5. REMEDY: FILE ACCEPTABLE AMENDED REPORT. #37001476K | Feb 23, 2017 DEFAULT | $0 |
| Aug 11, 2016 | Local Law CLASS - 2 FAILURE TO SUBMIT ACCEPTABLE 7TH ROUND REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALLS & APPURTENANCES REQUIRED BY 28-302.4. AGG2 HISTORY OF NONCOMPLIANCE ON 36023411K(AGG1),36019758H. #37001081X | Dec 29, 2016 IN VIOLATION | $0 |
| Jul 5, 2016 | Construction CLASS - 2 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. NOTED: OBSEVED AT TIME OF INSPECITON THE SPRINKLERS HEADS, COVERS TO BE PAINT. PAINT ON THE SPRINKLER HEADS IT WILL NOT ALOOW THE SPRINKLER SYSTEM TO WORK CO #35136493H | Aug 25, 2016 DEFAULT | $0 |
| Jul 5, 2016 | Construction CLASS - 3 OCCUPANCY CONTRARY TO THAT ALLOWED BY THE BUILDING DEPT RECORDS. BLDG DEPT RECORDS INDICATES ONE (1) OFFICE AT HTE 6TH FLR.AT TIME OF INSPECTION OBSERVED (1) OFFICES AT 6TH FLOOR EXISTING KITCHEN WAS REMOVED #35136492X | Aug 25, 2016 DEFAULT | $0 |
| May 27, 2016 | Construction CLASS - 2 FAILURE TO MAINTAIN EXTERIOR BLDG GENERAL NOTE-A/C UNITS MISSING BRACKETS DECORATIVE MASONRY ENTRANCE ERODED MORTAR JOINTS ALSO CRACK IN MASONRY-CORNER SOUTH WEST CORNER 1ST FK BRICK DEFECTIVE REAR-EAST ELEVATI #35174386J | Jul 14, 2016 DEFAULT | $0 |
| Apr 27, 2016 | Elevators CLASS - 2 59V15,56Y10,02B07. BRAKE MAINENANCE TAGS MISSING. HOIST MACHINE OIL LEAK. EMERGENCY 2WAY COMMUNICATION NOT WORKING. #38242278N | Jul 14, 2016 WRITTEN OFF | $0 |
| Dec 3, 2015 | Construction CLASS - 2 FAILURE TO COMPLY W/THE COMM'S ORDER TO FILE A C OF C W/THE DOB'S FOR ECB VIO#35127686J WHICH WAS ISSUED ON 3-30-15 FOR WORK W/O PERMIT & ECB VIO#35154095L WHICH WAS ISSUED ON 8-20-15 FOR FAILURE TO FILE C OF C #35154348K | Jan 21, 2016 IN VIOLATION | $0 |
| Oct 26, 2015 | Construction CLASS - 3 28-301.1 FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER. DEFECTS NOTED: INTERIOR SHEETROCK WALLS AND CEILING AE SPALLING AT SRO ROOMS NUMBER 74 & 72 AT 7TH FLR AND ACUSTICAL CEILING THE 15 STAINED WITH WAT #35154218M | Mar 17, 2016 DEFAULT | $0 |
| Oct 21, 2015 | Local Law CLASS - 2 FAILURE TO FILE AN ACCEPTABLE TECHNICAL REPORT IN COMPLIANCE W/CODE PROVISIONS: PERIODIC INSPECTION PF EXTERIOR WALLS & APPURTENANCES AS REQUIRED BY ARTICLE 28.302 & THE DOB'S RULES & REGULATIONS. REMEDY: FILE #36023411K | Mar 3, 2016 DEFAULT | $0 |
| Aug 20, 2015 | Construction CLASS - 2 FAILURE TO COMPLY W/COMM'S ORDER TO FILE A C OF C W/THE DOB FOR ECB VIOLATION #35127686J WHICH WAS ISSUED ON 3-30-15 FOR WORK W/PERMIT. REMEDY: FILE C OF C. #35154095L | Oct 8, 2015 IN VIOLATION | $0 |
| Aug 17, 2015 | Local Law CLASS - 2 FAILURE TO FILE AN ACCEPTABLE AMENDED CYCLE 6 REPORT TO THIS DEPARTMENT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL LOCAL LAW FISP REPORT.REM:FILE AN AMENDED REPORT FOLLOWING REMEDIAL REPAIR #36027857N | Dec 31, 2015 DEFAULT | $0 |
| Jun 11, 2015 | Construction CLASS - 2 FAILURE TO COMPLY W/THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION W/DOB FOR ECB VIOLATION #35127686J WHICH WAS ISSUED ON 3-302015 FOR WORK WITHOUT A PERMIT.RMDY: FILE CERTIFICATE OR CORRECTION. #35153956J | Jul 30, 2015 IN VIOLATION | $0 |
| Mar 30, 2015 | Construction CLASS - 3 WORK W/O PERMIT.WORK NOTED @ 6FL LEVEL NEXT TO APT6S THEY ERECTED A FULL HEIGHT PARTITION W/ DOOR FRAME CREATING A OFFICE SPACE FOR 5 WORK STATION.REM:OBTAIN PERMIT OR RESTORE PREMISES TO PRIOR LEGAL CONDITIONS #35127686J | May 28, 2015 IN VIOLATION | $0 |
| Sep 19, 2014 | Local Law CLASS - 2 FAILURE TO FILE AN ACCEPTABLE CYCLE 7 TECHNICAL REPORT IN COMPLIANCE WITH CODE PROVISIONS: PERIODIC INSPECTION OF EXTERIOR WALLS & APPURTENANCES AS REQUIRED BY ARTICLE 28-302 & THE DEPT OF BLDGS RULES & REGULAT #36019758H | Jan 8, 2015 WRITTEN OFF | $0 |
| Jul 30, 2014 | Cranes and Derricks CLASS - 2 FAILED TO MODIFY DEPT PRIOR TO USE/INSTALLATION OF OUTRIGGERS BEAMS IN CORRECTION T SUSPENDED SCAFFOLD.SWO ON SUSP SCAFFLOFS.REM:NOTIFY DEPT #35099502K | Sep 18, 2014 WRITTEN OFF | $0 |
| Mar 16, 2013 | Construction CLASS - 1 FAILURE TO COMPLY W/AN ORDER OF T HE COMMISSIONER. NOTED: ON 6-6-12 A SWO & VIOLATIONS WERE ISSUED BY INSPECTION C. MILLS #2427 FOR UNSAFE CONDITION HE FOUND ON RIGGING EQUIPMENT "OUTRIGGER BEAMS" RIGGING EQUIP #34989850P | May 2, 2013 ADMIT/IN-VIO | $0 |
| Jun 7, 2011 | Boilers CLASS - 2 B254/32A/50B/16/5A/50A-FRESH AIR FAN RUNNING ALL THE TIME,NOT WIRED CORRECTLY/50B-REMOVE ALL STORAGE FROM BOTH BOILER ROOM #32070800K | Oct 6, 2011 DEFAULT | $0 |
| Apr 30, 2010 | Elevators CLASS - 2 56Y13,56O02,98BB05,42D06,39Y02,10H07,17H07,70O02 56Y13 CLEAN OIL LEAK HOIST MACHINE & BED PLATE.56Y13-SEAL OIL LEAK HOIST MACHINE.42D06-PROPERLY SECURE RELAYS ON CONTROLLER.10H07-CAR DOOR GIBS ARE WORN ON BOTH #38210751N | Jun 24, 2010 DEFAULT | $0 |
| Dec 18, 2009 | Elevators CLASS - 2 10M07 42G1 56O02 39O02 50B10 100B07 71L11 10M07 -PROVIDE 2 GIBS ON CARDOORS REPLACE WORN 42G11-REPLACE ALL FUSES W/ JUMPER WIRES ON THEM 56O02-HOIST MACHINE OILED FROM MACHINE OIL DRIPPING DOWN FROM M/R 50B10-G #38207197H | Jun 3, 2010 DEFAULT | $0 |
| Nov 28, 2008 | Local Law CLASS - 2 FAILURE TO FILE AN AMENDED SIXTH ROUND REPORT ACCEPTABLE TO THIS DEPT.INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL LOCAL LAW 11/98 REPORT REMEDY:FILE AN AMENDED REPORT FOLLOWING REMEDIAL REPA #36005846K | Feb 25, 2010 DEFAULT | $0 |
| Oct 14, 2008 | Elevators CLASS - 2 100X10.05B10.56Y10.11.42R9.11.42O02.61T07.50T07.39O02.97B10.24X10.100M07.70O02.71L11.100X10 INTERCOM N/G 05B10 REDUCE GAP ON ALL CAR DOORS CHECK CENTRIE'S 56Y10.11 56Y10.11 MACHINE OILED REPAIR SEAL & CLEAN 42 #38192333Y | Apr 9, 2009 IN VIOLATION | $0 |
| Apr 30, 2008 | Local Law Non-Hazardous FAILURE TO FILE AN AMENDED 6TH ROUND REPORT ACCEPTABLE TO THIS DEPARTMENT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL LOCAL LAW 11/98 REPORT. REMEDY: FILE AN AMENDED REPORT FOLLOWING REMEDIA #34684414L | May 28, 2009 IN VIOLATION | $0 |
| Aug 2, 2007 | Elevators Non-Hazardous 10H11/5J1/17H11/84X10/60T7/59Q3/51O2/.10H-HOISTWAY DOOR GIBS WORN ON 2SPEED SIDE.5J-SINGLE SPEED CAR DOOR,REDUCE GAP AT RETURN POST.17H-WORNHOISTWAY DOOR GIBS-REPLACE.84X-CAR COMMUNICATIONS INOPERATIVE-REPAIR.6 #38168512J | May 1, 2008 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| Apr 30, 2026 | CONSTRUCTION FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER.AS NOTED AT TH E TIME OF INSPECTION,I OBSERVED ON EXP1,LOOSE BRICK,CRACKS IN BRICKS A ND MORTAR JOINTS,DAMAGED MORTAR JOINTS,LOOSE STUCCO AT 1ST FL SPANDREL S.ROOF:LOOSE TOP RAIL ON CHAIN LINK FENCE AT ROOF PERIMETER.FLOWER BOX ON WINDOW SILL O #SR0901RF | DOB VIOLATION - ACTIVE |
| Sep 23, 2024 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL LOW PRESSURE INSPECTION #04362 | DOB VIOLATION - ACTIVE |
| Sep 23, 2024 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL LOW PRESSURE INSPECTION #04363 | DOB VIOLATION - ACTIVE |
| Jan 8, 2024 | CONSTRUCTION EMERGENCY WORK ORDER DUE TO FIRE ESCAPE ON ROOF DETACHED FROM PARAPET HAZARDOUS CONDITIONS IF FIRE OR SOMEONE USES THE FIRE ESCAPE REMEDY: OWNER IMMED.REPAIR ALL DAMAGED APPURTENANCES;REPAIR OR REPLACE FIRE ESCAPE RAILING UNDER SUPERVISION OF LICENSED PROFESSIONAL #SR1099DO | DOB VIOLATION - ACTIVE |
| Jan 8, 2024 | CONSTRUCTION FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER. AT ROOF FIRE ESCAPE LOOSE AND NOT ATTACHED TO THE WALL AND RUSTED FIRE ESCAPE HAZARDOUS CONDITIONS IF FIRE OR SOMEONE USED THE FIRE ESCAPE.REMEDY: MAINTAIN BUILDING REPAIR OR REPLACE #SR10910DO | DOB VIOLATION - ACTIVE |
| Jan 8, 2024 | CONSTRUCTION FAILURE TO MAINT.EXTERIOR BLDGE WALLS & APPURT.AS NOTED.ON EXPO#1&4 WEST &NORTH ELEV.MISSING DAMAGED MORTAR JOINTS AT MULTIPLE FLOORS AND LOCATIONS.REMEDY:MAINTAIN EXTERIOR BUILDING WALLS AND APPLURTENANCES P PROVIDE ADEQUATE SAFETY MEASURES.REPAIR DAMAGED FACADE & APPURTENANCE #SR10901DO | DOB VIOLATION - ACTIVE |
| Sep 11, 2023 | CONSTRUCTION FAILURE TO MAINTAIN EXTERIOR BUILDING WALLS&APPURTENANCES.AT TIME OF INSPECTION OBSERVED EXP#1&4 WEST &NORTH ELEVATIONS:MISSING/DAMAGED MORTAR JOINTS@MULTIPLE FL.&LOC.EXP#3 E.ELEV.OBJECTS SITTING ON FIRE ESCAPES.ROOF LOOSE BLDG MATERAL @SEVERAL LOC.DAMAGED.BROKEN CHAIN LINK FENCE ON ROOF.REMEDY PROV #SR0902RF | DOB VIOLATION - ACTIVE |
| Feb 22, 2023 | NO REPORT AND / OR LATE FILING (FACADE) FAILED TO FILE FISP CYCLE 9B TECHNICAL REPORT BY 2/21/2023 #01635 | DOB VIOLATION - ACTIVE |
| Dec 1, 2022 | FAILURE TO POST ENERGY GRADE/SCORE FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3 #2200496 | DOB VIOLATION - ACTIVE |
| Nov 25, 2022 | CONSTRUCTION VEHICLE IMPACTING SIDEWALK SHED #ER01DB | DOB VIOLATION - ACTIVE |
| Nov 2, 2022 | FAILURE TO BENCHMARK FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 #00102 | DOB VIOLATION - ACTIVE |
| Aug 2, 2022 | FAILURE TO BENCHMARK FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 #00158 | DOB VIOLATION - ACTIVE |
| Jun 1, 2022 | FAILURE TO BENCHMARK FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 #00290 | DOB VIOLATION - ACTIVE |
| Aug 2, 2021 | FAILURE TO BENCHMARK FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 #00306 | DOB VIOLATION - ACTIVE |
| Jun 2, 2021 | FAILURE TO BENCHMARK FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 #00498 | DOB VIOLATION - ACTIVE |
| Apr 29, 2021 | FAILURE TO POST ENERGY GRADE/SCORE FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3 #2001401 | DOB VIOLATION - ACTIVE |
| Feb 2, 2021 | FAILURE TO BENCHMARK FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 #00169 | DOB VIOLATION - ACTIVE |
| Nov 2, 2020 | FAILURE TO BENCHMARK FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 #00221 | DOB VIOLATION - ACTIVE |
| Sep 16, 2020 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00105 | DOB VIOLATION - ACTIVE |
| Aug 2, 2020 | FAILURE TO BENCHMARK FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 #00435 | DOB VIOLATION - ACTIVE |
| May 2, 2020 | FAILURE TO BENCHMARK FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 #00435 | DOB VIOLATION - ACTIVE |
| Feb 2, 2020 | FAILURE TO BENCHMARK FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 #00228 | DOB VIOLATION - ACTIVE |
| Nov 2, 2019 | FAILURE TO BENCHMARK FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 #00310 | DOB VIOLATION - ACTIVE |
| Sep 6, 2019 | (OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2017 CAT 1 INSP/TST TST #05633 | DOB VIOLATION - ACTIVE |
| Aug 2, 2019 | FAILURE TO BENCHMARK FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 #00517 | DOB VIOLATION - ACTIVE |
| May 2, 2019 | FAILURE TO BENCHMARK FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 #00977 | DOB VIOLATION - ACTIVE |
| Jul 1, 2017 | PLUMBING THE DOB INTENDS TO REVOKE ALL PLUMBING APPROVALS AND PERMIT UNDER APPL ICATION #110549336 DUE TO SUSPENSION OF LICENSE. STOP ALL PLUMBING WOR K IMMEDIATELY EXCEPT TO MAKE SITE SAFE #PL0905OH | DOB VIOLATION - ACTIVE |
| Jan 3, 2017 | (OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2015 CAT 1 INSP/TST #07034 | DOB VIOLATION - ACTIVE |
| Mar 31, 2014 | ELEVATOR ANNUAL INSPECTION / TEST VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2012 INSPECTION/TEST #04844 | DOB VIOLATION - ACTIVE |
| Aug 30, 2013 | NO REPORT AND / OR LATE FILING (FACADE) FAILED TO FILE FISP CYCLE 7B TECHNICAL REPORT BY 08/21/2012 #00806 | DOB VIOLATION - ACTIVE |
| Oct 1, 2012 | ELEVATOR ANNUAL INSPECTION / TEST VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2011 INSPECTION/TEST #01662 | DOB VIOLATION - ACTIVE |
| Dec 13, 2011 | LOW PRESSURE BOILER VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2010 INSPECTION REPORT #03838 | DOB VIOLATION - ACTIVE |
| Dec 13, 2011 | ELEVATOR ANNUAL INSPECTION / TEST VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2010 INSPECTION/TEST #01804 | DOB VIOLATION - ACTIVE |
| Dec 13, 2011 | LOW PRESSURE BOILER VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2010 INSPECTION REPORT #03839 | DOB VIOLATION - ACTIVE |
| Oct 8, 2010 | ELEVATOR ANNUAL INSPECTION / TEST #02443 | DOB VIOLATION - ACTIVE |
| Jun 25, 2007 | LOCAL LAW 11/98 - FACADE #HAZ1391 | DOB VIOLATION - ACTIVE |
| Apr 2, 2007 | LOCAL LAW 10/81 - ELEVATOR #01743 | DOB VIOLATION - ACTIVE |
| Jan 6, 2004 | LANDMARK #04-0417 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Aug 12, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Jul 30, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Sep 23, 2024 | Boiler LBLVIO Violation Issued-Failure To File 2023 External Low Pressure Inspection Report | Active |
| Sep 23, 2024 | Boiler LBLVIO Violation Issued-Failure To File 2023 External Low Pressure Inspection Report | Active |
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2019 External Inspection Affirmation of Correction for LP Device | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2019 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2021 Cat1 Test Affirmation of Correction | Active |
| Oct 2, 2023 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2022 Periodic Inspection Affirmation of Correction | Active |
| Aug 11, 2023 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Report | Active |
| Feb 22, 2023 | Facades FISPNRF CYCLE 9B NO REPORT FILED | Active |
| Dec 1, 2022 | Energy Grade - LL33 FTP-EN-EGRDEA | Active |
| Nov 2, 2022 | Benchmarking - LL84 FTF-EN-BENCH | Active |
| Aug 2, 2022 | Benchmarking - LL84 FTF-EN-BENCH | Active |
| Jun 1, 2022 | Benchmarking - LL84 FTF-EN-BENCH | Active |
| Aug 2, 2021 | Benchmarking - LL84 FTF-EN-BENCH | Active |
| Jun 2, 2021 | Benchmarking - LL84 FTF-EN-BENCH | Active |
| Apr 29, 2021 | Energy Grade - LL33 FTP-EN-EGRDEA | Active |
| Feb 2, 2021 | Benchmarking - LL84 FTF-EN-BENCH | Active |
| Nov 2, 2020 | Benchmarking - LL84 FTF-EN-BENCH | Active |
| Sep 16, 2020 | AEUHAZ FTC-AEU-HAZ | Active |
| Aug 2, 2020 | Benchmarking - LL84 FTF-EN-BENCH | Active |
| May 2, 2020 | Benchmarking - LL84 FTF-EN-BENCH | Active |
| Feb 2, 2020 | Benchmarking - LL84 FTF-EN-BENCH | Active |
| Nov 2, 2019 | Benchmarking - LL84 FTF-EN-BENCH | Active |
| Sep 6, 2019 | Elevators ACC1 | Active |
| Aug 2, 2019 | Benchmarking - LL84 FTF-EN-BENCH | Active |
| May 2, 2019 | Benchmarking - LL84 FTF-EN-BENCH | Active |
| Jul 31, 2018 | Facades FISPNRF FAILED TO FILE FISP CYCLE 8B TECHNICAL REPORT BY 02/21/2018 | Active |
| Jan 3, 2017 | Elevators ACC1 | Active |
| Mar 31, 2014 | Elevators EVCAT1 | Active |
| Aug 30, 2013 | Facades FISPNRF FAILED TO FILE FISP CYCLE 7B TECHNICAL REPORT BY 08/21/2012 | Active |
| Oct 1, 2012 | Elevators EVCAT1 | Active |
| Oct 1, 2012 | Elevators EVCAT1 | Active |
| Dec 13, 2011 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2010 INSPECTION REPORT | Active |
| Dec 13, 2011 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2010 INSPECTION REPORT | Active |
| Dec 13, 2011 | Elevators EVCAT1 | Active |
| Dec 13, 2011 | Elevators EVCAT1 | Active |
| Oct 8, 2010 | Elevators VCAT1 | Active |
| Oct 8, 2010 | Elevators VCAT1 | Active |
| Jun 25, 2007 | Facades L1198 CYCLE 6 UNSAFE REPORT FILED | Active |
| Apr 2, 2007 | Elevators LL1081 | Active |
| Apr 2, 2007 | Elevators LL1081 | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Sep 25, 2026 | A | §27-2104(B) HMC POST A PROPER NOTICE REGARDING RENT STABILIZATION LAW, IN A FORM APPROVED BY THE COMMISSIONER, IN A CONSPICUOUS LOCATION WITHIN THE COMMON AREA AT THE BUILDINGS ENTRANCE. FOR MORE INFORMATION ABOUT SIGNAGE REQUIREMENTS, PLEASE VISIT: HTTPS://WWW.NYC.GOV/SITE/HPD/SERVICES-AND-INFORMA | Dec 29, 2026 |
| Sep 15, 2026 | C | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM LOCKED DOOR AT BOILER ROOM | Sep 21, 2026 |
| Sep 9, 2026 | C | Apt 4A · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 4A, 1st APARTMENT FROM WEST AT NORTH | Sep 5, 2026 |
| Sep 8, 2026 | B | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF DROP LADDER OBSTRUCTING FROM SAFE LANDING BY SCAFFOLDING 1ST FROM EAST AT SOUTH, AT BUILDING FRONT AT FIRE ESCAPE | Oct 13, 2026 |
| Sep 2, 2026 | C | Apt 4A · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 4A, 4th STORY, 2nd APARTMENT FROM NORTH AT EAST | Sep 1, 2026 |
| Aug 31, 2026 | A | §27-2045(B)(5) HMC, § 12-06, 12-10 RCNY POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN PRIVATE DWELLINGS MISSING | Dec 4, 2026 |
| Aug 31, 2026 | C | Apt 4A · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE BATHROOM LOCATED AT B-ROOM 4A, 4th STORY, 1st B-ROOM FROM NORTH AT EAST | Aug 29, 2026 |
| Aug 31, 2026 | A | §27-2104(B) HMC POST A PROPER NOTICE REGARDING RENT STABILIZATION LAW, IN A FORM APPROVED BY THE COMMISSIONER, IN A CONSPICUOUS LOCATION WITHIN THE COMMON AREA AT THE BUILDINGS ENTRANCE. FOR MORE INFORMATION ABOUT SIGNAGE REQUIREMENTS, PLEASE VISIT: HTTPS://WWW.NYC.GOV/SITE/HPD/SERVICES-AND-INFORMA | Dec 4, 2026 |
| Aug 31, 2026 | A | Apt 4A · § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING SHOWER HEAD IN THE BATHROOM LOCATED AT APT 4A, 4th STORY, 1st APARTMENT FROM NORTH AT EAST | Dec 4, 2026 |
| Aug 3, 2026 | A | Apt 6J · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL WALLS AND CEILING IN THE ROOM LOCATED AT B-ROOM 6J, 6th STORY, 1st B-ROOM FROM SOUTH AT WEST | Nov 6, 2026 |
| Apr 2, 2026 | A | Apt 7Y · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING LOCATED AT B-ROOM 7Y, 7th STORY, 3rd B-ROOM FROM NORTH AT EAST , SECTION ''NORTH'' | Jul 6, 2026 |
| Apr 1, 2026 | B | Apt 7A · § 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE CLOTHES AND BAGS IN THE ROOM LOCATED AT B-ROOM 7A, 7th STORY, 1st B-ROOM FROM SOUTH AT WEST , SECTION AT NORTH | May 6, 2026 |
| Jun 18, 2024 | B | Apt 5C · § 27-2005, 2012 HMC & § 309 MDL: ABATE THE NUISANCE CONSISTING OF EXCESSIVE STORAGE OF MATERIAL .. IN THE ENTIRE APARTMENT LOCATED AT APT 5C, 5th STORY, 3rd APARTMENT FROM WEST AT NORTH | Jul 23, 2024 |
| Jun 18, 2024 | A | Apt 7V · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL FLOOR TILES TROUGHOUT IN THE ENTIRE APARTMENT LOCATED AT APT 7V, 7th STORY | Sep 21, 2024 |
| Jun 17, 2024 | B | § 27-2026 ADM CODE REPAIR THE FLUSHING APPARATUS AND MAINTAIN SAME SO AS TO FLUSH EFFECTIVELY THE WATER CLOSET COMMUNITY BATHROOM AT PUBLIC HALL, 4th STORY, SECTION AT SOUTH | Jul 22, 2024 |
| May 30, 2024 | B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOODEN BASE INSIDE SINK CABINET AT 1st COMMUNITY KITCHEN FROM NORTH, 4th STORY, SECTION ''NORTH '' | Jul 4, 2024 |
| May 30, 2024 | B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL FLOOR TILES AT COMMUNITY ROOM , 7th STORY, SECTION ''SOUTH '' | Jul 4, 2024 |
| May 30, 2024 | B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES AT 1st COMMUNITY BATHROOM FROM NORTH, 4th STORY, SECTION ''NORTH '' | Jul 4, 2024 |
| May 30, 2024 | A | Apt 4X · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL WALLS AND CEILING LOCATED AT B-ROOM 4X, 4th STORY, 2nd B-ROOM FROM NORTH AT EAST , SECTION ''NORTH '' | Sep 2, 2024 |
| May 30, 2024 | A | Apt 4R · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL WALLS AND CEILING IN THE ROOM LOCATED AT B-ROOM 4R, 4th STORY, 4th B-ROOM FROM SOUTH AT WEST , SECTION ''NORTH'' | Sep 2, 2024 |
| May 30, 2024 | B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL FLOOR TILES IN COMMUNITY ROOOM , 6th STORY, SECTION ''SOUTH'' | Jul 4, 2024 |
| May 30, 2024 | B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES AT 2nd COMMUNITY BATHROOM FROM NORTH, 7th STORY, SECTION ''SOUTH'' | Jul 4, 2024 |
| May 30, 2024 | A | Apt 7G · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING AND ALL WALLS, IN THE ROOM LOCATED AT B-ROOM 7G, 7th STORY, 3rd B-ROOM FROM NORTH AT EAST , SECTION AT SOUTH | Sep 2, 2024 |
| May 30, 2024 | A | Apt 40 · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL WALLS AND CEILING IN THE ROOM LOCATED AT B-ROOM 40, 4th STORY, 1st B-ROOM FROM SOUTH AT WEST , SECTION ''NORTH'' | Sep 2, 2024 |
| Aug 21, 2023 | C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE DUE TO DEFECTIVE HINGES AT 1st COMMUNITY BATHROOM FROM NORTH, 3rd STORY, SECTION AT SOUTH | Sep 4, 2023 |
| Aug 21, 2023 | C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE *MISSING* AT COMMUNITY KITCHEN, 6th STORY, SECTION AT SOUTH | Sep 4, 2023 |
| Aug 21, 2023 | C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE *MISSING* AT COMMUNITY KITCHEN, 5th STORY, SECTION AT SOUTH | Sep 4, 2023 |
| Aug 21, 2023 | B | Apt 7U · § 27-2005, 2012 HMC & § 309 MDL: ABATE THE NUISANCE CONSISTING OF EXCESSIVE STORAGE OF MATERIAL .. LOCATED AT B-ROOM 7U, 7th STORY, 2nd B-ROOM FROM NORTH AT EAST , SECTION AT NORTH | Sep 25, 2023 |
| Aug 21, 2023 | B | Apt 6E · § 27-2005, 2012 HMC & § 309 MDL: ABATE THE NUISANCE CONSISTING OF EXCESSIVE STORAGE OF MATERIAL LOCATED AT B-ROOM 6E, 6th STORY, 5th B-ROOM FROM NORTH AT EAST , SECTION AT SOUTH | Sep 25, 2023 |
| Aug 21, 2023 | C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE DUE TO DEFECTIVE HINGES AT 1st COMMUNITY BATHROOM FROM NORTH, 3rd STORY, SECTION AT NORTH | Sep 4, 2023 |
| Aug 21, 2023 | C | § 27-2005, 2007 ADM CODE REMOVE DEVICE PREVENTING DOOR FROM BEING SELF-CLOSING CONSISTING OF A PERMANENTLY INSTALLED KICK STAND STOPPER AT COMMUNITY KITCHEN, 3rd STORY, SECTION AT NORTH | Sep 4, 2023 |
| Aug 21, 2023 | C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE *MISSING* AT COMMUNITY KITCHEN, 4th STORY, SECTION AT SOUTH | Sep 4, 2023 |
| Aug 21, 2023 | C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE *MISSING* AT COMMUNITY KITCHEN, 7th STORY, SECTION AT SOUTH | Sep 4, 2023 |
| Aug 21, 2023 | B | Apt 6J · § 27-2005, 2012 HMC & § 309 MDL: ABATE THE NUISANCE CONSISTING OF EXCESSIVE STORAGE OF MATERIAL LOCATED AT B-ROOM 6J, 6th STORY, 2nd B-ROOM FROM SOUTH AT WEST , SECTION AT SOUTH | Sep 25, 2023 |
| Aug 21, 2023 | A | Apt 7C · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL WALLS AND CEILING LOCATED AT B-ROOM 7C, 7th STORY, 3rd B-ROOM FROM NORTH AT EAST , SECTION AT SOUTH | Nov 24, 2023 |
| Jul 14, 2023 | B | Apt 7C · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL FLOOR TILES IN THE 1st ROOM FROM NORTH LOCATED AT SRO 7C, 7th STORY, 3rd SINGLE ROOM OCCUPANCY FROM NORTH AT EAST , SECTION ''SOUTH'' | Aug 18, 2023 |
| Jul 14, 2023 | A | Apt 7C · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING AND ALL WALLS IN THE 1st ROOM FROM NORTH LOCATED AT SRO 7C, 7th STORY, 3rd SINGLE ROOM OCCUPANCY FROM NORTH AT EAST , SECTION ''SOUTH'' | Oct 17, 2023 |
| Jul 14, 2023 | B | Apt 7C · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR SOUTH AND WEST WALL IN THE 1st ROOM FROM NORTH LOCATED AT SRO 7C, 7th STORY, 3rd SINGLE ROOM OCCUPANCY FROM NORTH AT EAST , SECTION ''SOUTH'' | Aug 18, 2023 |
| Jul 14, 2023 | B | Apt 7C · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT NORTH WALL IN THE 1st ROOM FROM NORTH LOCATED AT SRO 7C, 7th STORY, 3rd SINGLE ROOM OCCUPANCY FROM NORTH AT EAST , SECTION ''SOUTH'' | Aug 18, 2023 |
| Jun 2, 2023 | C | Apt 4J · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE 1st ROOM FROM NORTH LOCATED AT B-ROOM 4J, 4th STORY, 1st B-ROOM FROM WEST AT NORTH | Jun 28, 2023 |
| Oct 20, 2022 | B | Apt 5K · § 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE UNSANITARY CONDITIONS LOCATED AT B-ROOM 5K, 5th STORY, 4th B-ROOM FROM EAST AT SOUTH | Nov 24, 2022 |
| Aug 29, 2022 | B | Apt 7C · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL FLOOR TILES AT WALKING AREAS IN THE 1st ROOM FROM EAST LOCATED AT APT 7C, 7th STORY, 3rd APARTMENT FROM NORTH AT EAST , SECTION ''SOUTH'' | Oct 3, 2022 |
| Aug 24, 2022 | B | Apt 7C · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT SOUTH AND WEST WALLS IN THE 1st ROOM FROM EAST LOCATED AT APT 7C, 7th STORY, 3rd APARTMENT FROM NORTH AT EAST , SECTION ''SOUTH'' | Sep 28, 2022 |
| Aug 24, 2022 | A | Apt 7C · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL WALLS CELING AND TRIM IN THE 1st ROOM FROM EAST LOCATED AT APT 7C, 7th STORY, 3rd APARTMENT FROM NORTH AT EAST , SECTION ''SOUTH'' | Nov 27, 2022 |
| Aug 19, 2022 | C | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE AT COMMUNITY KITCHEN, 7th STORY, SECTION ''SOUTHWING'' | Sep 14, 2022 |
| Aug 19, 2022 | C | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE AT COMMUNITY KITCHEN, 7th STORY, SECTION ''NORTHWING'' | Sep 14, 2022 |
| Jul 22, 2022 | B | Apt 6L · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL FLOOR TILES IN THE 1st ROOM FROM EAST LOCATED AT APT 6L, 6th STORY, 4th APARTMENT FROM SOUTH AT WEST , SECTION ''SOUTH'' | Aug 26, 2022 |
| Jul 22, 2022 | B | Apt 6L · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE WINDOW COUNTER BALANCE LOWER SASH IN THE 1st ROOM FROM EAST LOCATED AT APT 6L, 6th STORY, 4th APARTMENT FROM SOUTH AT WEST , SECTION ''SOUTH'' | Aug 26, 2022 |
| Jul 22, 2022 | B | Apt 6L · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF AIR CONDITIONER UNIT NOT SECURELY INSTALLED AT WINDOW IN THE 1st ROOM FROM EAST LOCATED AT APT 6L, 6th STORY, 4th APARTMENT FROM SOUTH AT WEST , SECTION ''SOUTH'' | Aug 26, 2022 |
| Jul 8, 2022 | A | Apt 5J · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL FLOOR TILES IN THE ROOM LOCATED AT B-ROOM 5J, 5th STORY, 4th B-ROOM FROM SOUTH AT WEST | Oct 11, 2022 |
| Jul 8, 2022 | B | Apt 7F · § 27-2005, 2012 HMC & § 309 MDL: ABATE THE NUISANCE CONSISTING OF EXCESSIVE STORAGE OF MATERIAL BAGS,CLOTHES AND HOUSEHOLD ITEMS IN THE ROOM LOCATED AT B-ROOM 7F, 7th STORY, 6th B-ROOM FROM NORTH AT EAST , SECTION AT SOUTH | Aug 12, 2022 |
| Jul 8, 2022 | A | Apt 4Z · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL FLOOR TILES IN THE ROOM LOCATED AT B-ROOM 4Z, 4th STORY | Oct 11, 2022 |
| Jul 8, 2022 | A | Apt 5L · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTER BALANCE, UPPER AND LOWER WINDOW SASHES IN THE ROOM LOCATED AT B-ROOM 5L, 5th STORY, B-ROOM AT WEST , SECTION AT NORTH | Oct 11, 2022 |
| Apr 21, 2022 | B | Apt 7H · § 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE FLOOR IN THE ENTIRE APARTMENT LOCATED AT APT 7H, 7th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''SOUTH'' | May 26, 2022 |
| Apr 21, 2022 | B | Apt 7Q · § 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE FLOOR IN THE ENTIRE APARTMENT LOCATED AT APT 7Q, 7th STORY, 2nd APARTMENT FROM SOUTH AT WEST , SECTION ''NORTH'' | May 26, 2022 |
| Dec 9, 2021 | A | Apt 4N · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL FLOOR TILES IN THE 1st ROOM FROM NORTH LOCATED AT B-ROOM 4N, 4th STORY, 5th B-ROOM FROM SOUTH AT WEST | Mar 14, 2022 |
| Jul 6, 2021 | A | Apt 7Z · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AND ALL WALLS IN THE ROOM LOCATED AT B-ROOM 7Z, 7th STORY, 6th B-ROOM FROM NORTH AT EAST , SECTION AT NORTH | Oct 9, 2021 |
| Jun 8, 2021 | A | Apt 7F · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING IN THE ROOM LOCATED AT B-ROOM 7F, 7th STORY, 6th B-ROOM FROM NORTH AT EAST , SECTION ''SOUTH'' | Sep 11, 2021 |
| Nov 2, 2020 | A | Apt 7F · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING AND ALL WALLS IN THE ROOM LOCATED AT B-ROOM 7F, 7th STORY, B-ROOM AT EAST | Feb 5, 2021 |
| Jun 17, 2020 | C | Apt 4L · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE 3rd ROOM FROM NORTH LOCATED AT B-ROOM 4L, 4th STORY, 3rd B-ROOM FROM SOUTH AT WEST | Jul 13, 2020 |
Showing 60 of 69. Full list on the agency site.
| Date | Source | What | Now |
|---|---|---|---|
| Nov 6, 2026 | ECB | Construction: OBSERVED SIDE WALK SHED UNDER ACTIVE PERMIT # M00638361-I1-SH AFFIXED AT THE WRONG LOCATION AND NOT IN COMPLIANCE AS PER CODE, THIS ALSO IS CAUSING OBSTRUCTION TO PUBLIC VIEW OF STREET SIGNS AT THE INTERSECTION | Open |
| Nov 6, 2026 | ECB | Construction: OBSERVED PIPE SCAFFOLD INSTALLED IS NOT CONFORMING TO APPROVED PLANS UNDER JOB # M01284330-I1-SH, DUE TO THE SECTION ON SWS IS NOT INDICATED ON PLANS., CONFORM WORK TO APPROVED CONSTRUCTION DOCUMENTS/AMENDMENTS | Open |
| Sep 25, 2026 | HPD A | §27-2104(B) HMC POST A PROPER NOTICE REGARDING RENT STABILIZATION LAW, IN A FORM APPROVED BY THE COMMISSIONER, IN A CONSPICUOUS LOCATION WITHIN THE COMMON AREA AT THE BUILDINGS ENTRANCE. FOR MORE INFORMATION ABOUT SIGNAGE REQUIREMENTS, PLEASE VISIT: HTTPS://WWW.NYC.GOV/SITE/HPD/SERVICES-AND-INFORMA | Open |
| Sep 18, 2026 | HPD C | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES AT COMMUNITY KITCHEN, 4th STORY, SECTION AT NORTH | Closed |
| Sep 18, 2026 | HPD C | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF HOT WATER EXCEEDING THE MAXIMUM TEMPERATURE OF 130F AT COMMUNITY BATHROOM, 4th STORY | Closed |
| Sep 16, 2026 | HPD C | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE BATHROOM LOCATED AT B-ROOM 4A, 4th STORY | Closed |
| Sep 15, 2026 | HPD C | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES AT COMMUNITY KITCHEN, 4th STORY | Closed |
| Sep 15, 2026 | HPD C | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM LOCKED DOOR AT BOILER ROOM | Open |
| Sep 10, 2026 | ECB | Construction: AT TIME OF INSPECTION, OBSERVED 7-STORY BUILDING WITH SIDEWALK SHED AT EXPOSURES 1, 2, AND 4 AND SCAFFOLD AT EXPOSURE 3 NOT MAINTAINED. NETTING WAS MISSING AT THE CORNER OF EXPOSURES 2 AND 3. EXPOSED PLANKS, A | Open |
| Sep 10, 2026 | HPD C | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ROOM LOCATED AT B-ROOM 4A, 4th STORY, 1st B-ROOM FROM SOUTH AT WEST , SECTION AT NORTH | Closed |
| Sep 9, 2026 | HPD C | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 4A, 1st APARTMENT FROM WEST AT NORTH | Open |
| Sep 8, 2026 | HPD B | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF DROP LADDER OBSTRUCTING FROM SAFE LANDING BY SCAFFOLDING 1ST FROM EAST AT SOUTH, AT BUILDING FRONT AT FIRE ESCAPE | Open |
| Sep 4, 2026 | HPD C | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES AT COMMUNITY BATHROOM, 7th STORY | Closed |
| Sep 2, 2026 | HPD C | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 4A, 4th STORY, 2nd APARTMENT FROM NORTH AT EAST | Open |
| Sep 1, 2026 | HPD C | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES AT COMMUNITY BATHROOM, 4th STORY | Closed |
| Sep 1, 2026 | HPD C | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM NO ACCESS TO THE BOILER ROOM AT COMMUNITY BATHROOM, 4th STORY | Closed |
| Aug 31, 2026 | HPD A | §27-2045(B)(5) HMC, § 12-06, 12-10 RCNY POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN PRIVATE DWELLINGS MISSING | Open |
| Aug 31, 2026 | HPD C | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE BATHROOM LOCATED AT B-ROOM 4A, 4th STORY, 1st B-ROOM FROM NORTH AT EAST | Open |
| Aug 31, 2026 | HPD A | §27-2104(B) HMC POST A PROPER NOTICE REGARDING RENT STABILIZATION LAW, IN A FORM APPROVED BY THE COMMISSIONER, IN A CONSPICUOUS LOCATION WITHIN THE COMMON AREA AT THE BUILDINGS ENTRANCE. FOR MORE INFORMATION ABOUT SIGNAGE REQUIREMENTS, PLEASE VISIT: HTTPS://WWW.NYC.GOV/SITE/HPD/SERVICES-AND-INFORMA | Open |
| Aug 31, 2026 | HPD A | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING SHOWER HEAD IN THE BATHROOM LOCATED AT APT 4A, 4th STORY, 1st APARTMENT FROM NORTH AT EAST | Open |
| Aug 20, 2026 | HPD C | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES AT COMMUNITY BATHROOM, 4th STORY | Closed |
| Aug 14, 2026 | ECB | Construction: OBSERVED AT TIME OF INSPECTION GAS PIPING WAS REROUTING FROM PRE-EXISTING KITCHEN IN BASEMENT TO SUPPLY 2 COMMERCIAL FRYER AND GRILL IN FIRST FLOOR DELI . NO PERMIT ON FILE WITH DEPARTMENT OF BUILDINGS., OBTAIN | Open |
| Aug 14, 2026 | ECB | Construction: OBSERVED AT TIME OF INSPECTION, GAS PIPING WAS INSTALLED WITH PROHIBITED UNION AND COUPLING.AS PER FGC 403.10.1.1 UNIONS AND CLOSE NIPPLE SHALL BE PROHIBITED., REPAIR AND/OR REPLACE | Open |
| Aug 12, 2026 | DOB Safety | AEUHAZ: | Open |
| Aug 12, 2026 | HPD C | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES AT COMMUNITY BATHROOM, 4th STORY | Closed |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 14, 2026, 1:20 PM ET. BBL 1020580001.