4 floors · 36,000 sq ft · built 1931 · class N2 · owner of record: Nyc Department Of Homeless Services
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 65 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 36,000 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 186 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 186 days | Annual filing |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 796 days | Next cycle year 2028 |
| Annual boiler inspection (2 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-08-12 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Sep 24, 2026 | Elevators CLASS - 2 CLASS 2. CAR DOOR GIBS WERE FOUND WORN OR MISSING, COMPROMISING PROPER DOOR GUIDANCE AND RETENTION. ACCUMULATED DIRT WAS OBSERVED IN THE DOOR SILL, ON THE CAR TOP, AND IN THE PIT, REQUIRING CLEANING, AS PER ASM #39205467X | Oct 2, 2026 POP/IN-VIO | $0 |
| Mar 20, 2026 | Elevators CLASS - 2 CLASS 2: FIREFIGHTER'S SERVICE PHASE I SWITCH MULFUNCTIONING - CYLINDER ROTATES 360, NOT ALWAYS ACTIVATING PHASE I OPERATION MODE, REPAIR. TOE GUARD LOOSE, SECURE. PROVIDE UPDATED MAINTENANCE LOG (LAST RECORDS #39181246Z | Apr 10, 2026 POP/IN-VIO | $0 |
| Mar 20, 2026 | Unknown CLASS - 1 ELECTRICAL WORK WITHOUT A PERMIT. OBSERVED IN EXP #2 IN THE ALLEY THAT THE INSTALLATION OF A/C SPLIT UNIT COMPRESSOR, AND ONE NEW ELECTRICAL PANEL IN CAFETERIA TO POWER UNIT. FOUND NO PERMIT ON FILE IN BIZ/ DOB #39181298K | Aug 7, 2026 POP/IN-VIO | $0 |
| Mar 20, 2026 | Construction CLASS - 1 IN BASEMENT USING PVC PIPING ON WASTE LINE UNDER SLOPE SINK. IN CAFETERIA ROOM OPEN WASTE LINE. DOOR BY THE WATER METER STRIKES WASTE LINE PIPE. IN BASEMENT JIM CAPS ARE USED ON WASTE LINES. ALSO PIPE PENETRATI #39181286N | Aug 7, 2026 POP/IN-VIO | $0 |
| Mar 20, 2026 | Construction CLASS - 1 OBSERVED THROUGHOUT THE BUILDING NO TRAP WRAP INSULATION UNDER SINKS IN BATHROOMS. ON 4TH FLOOR IN BATHROOM SPRINKLER HEAD NOT INSTALLED PROPERLY. THID FLOOR BATHROOM VENT IS BACK PITCHED. ON SECOND FLOOR BATHR #39181285L | Aug 7, 2026 POP/IN-VIO | $0 |
| Mar 20, 2026 | Unknown CLASS - 1 ELECTRICAL CLOSET NOT DEDICATED TO ELECTRICAL DISTRIBUTION EQUIPMENT ONLY. OBSERVED ON THE 1ST FL ELECTRICAL CLOSET WAS NOT DEDICATED TO ELECTRICAL FOUND COMPUTER SERVERS AND CAMERA RECORDING EQUIPMENT IN THE S #39181297Z | Aug 7, 2026 POP/IN-VIO | $0 |
| Aug 15, 2025 | Elevators CLASS - 2 CLASS 2: FIRE TABS ON HOISTWAY DOORS HANGING ROLLERS ARE NOT SET TO THE UPRIGHT POSITION, RE-ADJUST. TOE GUARD LOOSE, SECURE. BOTH HOISTWAY AND CAR DOORS ARE NOT SETTTING TO FULLY OPEN POSITION, ADJUST. CAR DOO #39157266X | Aug 29, 2025 POP/IN-VIO | $0 |
| Sep 3, 2024 | Elevators CLASS - 1 DOOR ZONE RESTRICTOR INOPERATIVE. THIS IS A SAFETY FEATURE WHICH ENSURES PASSENGER SAFETY. REMEDY: TO RESTORE SERVICE, CALL THE D.O.B. ELEVATOR DIVISION AT (212) 393-2144 FOR A REINSPECTION. CLASS 2 ITEMS:BRAKE #39123781P | Oct 18, 2024 POP/IN-VIO | $0 |
| Sep 5, 2018 | Construction CLASS - 1 AN UNLAWFUL ACT FAILUR TO COMPLY WITH AN ORDER TO THE COMMISSIONER.FAILURE TO CORRECT AND CERTIFY SUMMONS #35294527K(35294527K)FOR FAILURE TO GROUND THE ELECTRICAL INSTALLATION THAT VIOLATION WAS ISSUED ON 10/1 #35358606Z | Nov 2, 2018 DEFAULT | $6,250 |
| Issued | Violation | Status |
|---|---|---|
| Mar 4, 2020 | ELEVATOR #9028/673643 | DOB VIOLATION - ACTIVE |
None open.
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Sep 24, 2026 | ECB | Elevators: CLASS 2. CAR DOOR GIBS WERE FOUND WORN OR MISSING, COMPROMISING PROPER DOOR GUIDANCE AND RETENTION. ACCUMULATED DIRT WAS OBSERVED IN THE DOOR SILL, ON THE CAR TOP, AND IN THE PIT, REQUIRING CLEANING, AS PER ASM | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 27, 2026, 5:10 AM ET. BBL 2025870001.