3 floors · 76,849 sq ft · built 1925 · class E9 · owner of record: 63rd Street Realty Ii Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 66 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 76,849 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 187 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 187 days | Annual filing |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 11 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 431 days | Next cycle year 2027 |
| Energy audit and retro-commissioning (2028) Likely applies Local Law 87 · Calendar year 2028 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 5538). Agency page | Dec 31, 2028 in 797 days | Next due 2028 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Mar 6, 2017 | Plumbing CLASS - 1 FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER: LACK OF A SYSTEM OF AUTOMATIC SPRINKLERS WHERE REQUIRED PER BC 903.2; 27-954. ON 3/6/17 @ APPROX 10:15AM OBSERVED CARBOARD PLASTIC & WOODEN SKIDS STORED IN A C #35204516N | Sep 27, 2017 IN VIOLATION | $0 |
| Mar 3, 2017 | Construction CLASS - 2 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. NOTED: ON 2ND FLOORCONCRETE ENCASED STEEL HAS SECTIONS SPALLING AND EXPOSES STEEL,STRESS CRACKS THROUGHOUT AT CEILING AND EXTERIOR WALL ALSO NOTED LARGE HORIZ #35219790H | Sep 27, 2017 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| Sep 6, 2019 | (OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2017 CAT 1 INSP/TST TST #09957 | DOB VIOLATION - ACTIVE |
| Jan 26, 2018 | (OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2016 CAT 1 INSP/TST #11533 | DOB VIOLATION - ACTIVE |
| Jan 26, 2018 | (OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2016 CAT 1 INSP/TST #11532 | DOB VIOLATION - ACTIVE |
| Mar 3, 2017 | CONSTRUCTION IN BUILDING APPROX 510' X 82; WITH MULTIPLE HOUSE #'S , HAS AT 2ND FL #ER1101RJ | DOB VIOLATION - ACTIVE |
| Mar 3, 2017 | CONSTRUCTION IN BUILDING APPRX. 510'X 82' WITH MULTIPLE HOUSE #'S HAS AT 2ND FLOOR IN A ROOM SPALLING AT CONCRETE ENCASED STEEL WITH MULTIPLE STRESS CRACKS , ALSO NOTED IN THE MIDDLE OF WAREHOUSE LARGE HORIZONTAL CRACK APPEARS WITH MULTIPLE STRESS CRACKS #ER1101RJ | DOB VIOLATION - ACTIVE |
| Jan 3, 2017 | (OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2015 CAT 1 INSP/TST #11375 | DOB VIOLATION - ACTIVE |
| Jan 3, 2017 | (OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2015 CAT 1 INSP/TST #11376 | DOB VIOLATION - ACTIVE |
| May 30, 2014 | (OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2012 CAT 1 INSP/TST #10525 | DOB VIOLATION - ACTIVE |
| Oct 1, 2012 | ELEVATOR ANNUAL INSPECTION / TEST VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2011 INSPECTION/TEST #03180 | DOB VIOLATION - ACTIVE |
| Oct 20, 2010 | CONSTRUCTION OCCUPANCY CONTRARY TO THAT ALLOWED BY CERTIFICATE OF OCCUPANCY REMEDY; DISCONTINUE ILLEGAL USE/OCCUPANCY OR AMEND C/O #1103WG | DOB VIOLATION - ACTIVE |
| Oct 8, 2010 | ELEVATOR ANNUAL INSPECTION / TEST #04279 | DOB VIOLATION - ACTIVE |
| Sep 18, 2008 | CONSTRUCTION #1202DF | DOB VIOLATION - ACTIVE |
| Aug 22, 2008 | CONSTRUCTION STOP ALL WORK IMMEDIATELY,MAKE SITE SAFE,CONTACT THE DOB #1101DF | DOB VIOLATION - ACTIVE |
| Aug 16, 1993 | LOCAL LAW 62/91 - BOILERS #21284 | DOB VIOLATION - ACTIVE |
| Aug 16, 1993 | LOCAL LAW 62/91 - BOILERS #21285 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Sep 6, 2019 | Elevators ACC1 | Active |
| Jan 26, 2018 | Elevators ACC1 | Active |
| Jan 26, 2018 | Elevators ACC1 | Active |
| Jan 3, 2017 | Elevators ACC1 | Active |
| Jan 3, 2017 | Elevators ACC1 | Active |
| May 30, 2014 | Elevators ACC1 | Active |
| Oct 1, 2012 | Elevators EVCAT1 | Active |
| Oct 1, 2012 | Elevators EVCAT1 | Active |
| Oct 8, 2010 | Elevators VCAT1 | Active |
| Oct 8, 2010 | Elevators VCAT1 | Active |
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 26, 2026, 4:57 AM ET. BBL 3055380007.