5 floors · 25 apartments · 20,455 sq ft · built 1915 · class C1 · owner of record: G&M Properties Ii Housing Development Fu Nd Corpora
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 46 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 46 days | Annual |
| Annual boiler inspection (3 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-01-11 (Accepted). Agency page | Dec 31, 2026 in 46 days | 1 of 3 without an accepted 2026 report yet |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 62 days | Annual |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | No current registration found |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 5 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1142 days | Next cycle year 2029 |
None open.
| Issued | Violation | Status |
|---|---|---|
| Jun 20, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION #04943 | DOB VIOLATION - ACTIVE |
| Jun 20, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION #04944 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Jun 20, 2023 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Jun 20, 2023 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Sep 29, 2026 | B | § 27-2037 ADM CODE PROVIDE ADEQUATE LIGHTING AT CEILING AT FIRE PASSAGE WAY, SECTION ''SOUTH'' | Nov 3, 2026 |
| Sep 29, 2026 | B | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES HOUSEHOLD ITEMS AT 4TH STORY BALCONY AT 2ND FIRE ESCAPE FROM NORTH AT WEST EXTERIOR WALL AT FIRE ESCAPE | Nov 3, 2026 |
| Sep 29, 2026 | B | Apt 4C · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 4C, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH | Nov 3, 2026 |
| Sep 29, 2026 | B | Apt APT 4C · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE RETURN BUZZER INTERCOM SYSTEM FROM THE BUILDING ENTRANCE DOOR TO THE APARTMENT WALL PANEL AT SOUTH WALL LOCATED AT APT APT 4C, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH | Nov 3, 2026 |
| Sep 29, 2026 | C | Apt 4C · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE [HINGE] DOOR IN THE ENTRANCE LOCATED AT APT 4C, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH | Oct 13, 2026 |
| Sep 29, 2026 | B | Apt 4C · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE GASKET SEAL AT DOOR REFRIGERATOR (TOP) IN THE KITCHEN LOCATED AT APT 4C, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH | Nov 3, 2026 |
| Sep 29, 2026 | B | Apt 4C · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 4C, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH | Nov 3, 2026 |
| Sep 29, 2026 | B | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LIGHT FIXTURE AT CEILING AT PUBLIC HALL, 1st STORY | Nov 3, 2026 |
| Aug 18, 2026 | B | Apt 5A · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LOWERE SASH COUNTER BALANCE AT FIRE ESCAPE WINDOW IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 5A, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST | Sep 22, 2026 |
| Aug 18, 2026 | B | Apt 5A · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE COUNTER TOP AT SINK IN THE KITCHEN LOCATED AT APT 5A, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST | Sep 22, 2026 |
| Aug 18, 2026 | B | Apt 5A · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING LOCATED AT APT 5A, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST | Sep 22, 2026 |
| Aug 18, 2026 | B | Apt 5A · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES MISSING LOCATED AT APT 5A, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST | Sep 22, 2026 |
| Aug 18, 2026 | A | Apt 5A · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE DOOR IN THE BATHROOM LOCATED AT APT 5A, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST | Nov 21, 2026 |
| Aug 18, 2026 | B | Apt 5A · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LIGHT FIXTURE AT CEILING IN THE KITCHEN LOCATED AT APT 5A, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST | Sep 22, 2026 |
| Jan 20, 2026 | B | Apt 3B · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE RECESSES OF THE 1ST., WINDOW FROM WEST AT NORTH IN THE 2nd ROOM FROM EAST LOCATED AT APT 3B, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST | Feb 24, 2026 |
| Jan 20, 2026 | B | Apt 3B · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE RECESSES OF THE 1ST., WINDOW FROM WEST AT NORTH IN THE 4th ROOM FROM EAST LOCATED AT APT 3B, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST | Feb 24, 2026 |
| Jan 20, 2026 | C | Apt 3B · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 3B, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST | Feb 15, 2026 |
| Jan 20, 2026 | B | Apt 3B · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE BATHROOM LOCATED AT APT 3B, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST | Feb 24, 2026 |
| Nov 12, 2019 | B | Apt 1C · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). ..DEFECTIVE LOCATED AT APT 1C, 1st STORY, 1st APARTMENT FROM NORTH AT EAST | Dec 17, 2019 |
| Nov 12, 2019 | B | Apt 1C · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR ..DEFECTIVE LOCATED AT APT 1C, 1st STORY, 1st APARTMENT FROM NORTH AT EAST | Dec 17, 2019 |
| Date | Source | What | Now |
|---|---|---|---|
| Sep 29, 2026 | HPD B | § 27-2037 ADM CODE PROVIDE ADEQUATE LIGHTING AT CEILING AT FIRE PASSAGE WAY, SECTION ''SOUTH'' | Open |
| Sep 29, 2026 | HPD B | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES HOUSEHOLD ITEMS AT 4TH STORY BALCONY AT 2ND FIRE ESCAPE FROM NORTH AT WEST EXTERIOR WALL AT FIRE ESCAPE | Open |
| Sep 29, 2026 | HPD B | § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 4C, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH | Open |
| Sep 29, 2026 | HPD B | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE RETURN BUZZER INTERCOM SYSTEM FROM THE BUILDING ENTRANCE DOOR TO THE APARTMENT WALL PANEL AT SOUTH WALL LOCATED AT APT APT 4C, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH | Open |
| Sep 29, 2026 | HPD C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE [HINGE] DOOR IN THE ENTRANCE LOCATED AT APT 4C, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH | Open |
| Sep 29, 2026 | HPD B | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE GASKET SEAL AT DOOR REFRIGERATOR (TOP) IN THE KITCHEN LOCATED AT APT 4C, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH | Open |
| Sep 29, 2026 | HPD B | § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 4C, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH | Open |
| Sep 29, 2026 | HPD B | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LIGHT FIXTURE AT CEILING AT PUBLIC HALL, 1st STORY | Open |
| Aug 18, 2026 | HPD B | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LOWERE SASH COUNTER BALANCE AT FIRE ESCAPE WINDOW IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 5A, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST | Open |
| Aug 18, 2026 | HPD B | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE COUNTER TOP AT SINK IN THE KITCHEN LOCATED AT APT 5A, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST | Open |
| Aug 18, 2026 | HPD B | § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING LOCATED AT APT 5A, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST | Open |
| Aug 18, 2026 | HPD B | § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES MISSING LOCATED AT APT 5A, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST | Open |
| Aug 18, 2026 | HPD A | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE DOOR IN THE BATHROOM LOCATED AT APT 5A, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST | Open |
| Aug 18, 2026 | HPD B | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LIGHT FIXTURE AT CEILING IN THE KITCHEN LOCATED AT APT 5A, 5th STORY, 1st APARTMENT FROM SOUTH AT WEST | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 15, 2026, 3:33 AM ET. BBL 2028760087.