Brooklyn · Block 2062 · Lot 24 · 11201

163 Willoughby Street

30 floors · 99 apartments · 84,990 sq ft · built 2025 · class D7 · owner of record: 159 Willoughby Realty Llc

0open violations
$92,500ECB/OATH penalties owed
0HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueRegistration expired 2004-10-01
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 58 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 58 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 74 days
Annual
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 84,990 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 179 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 179 days
Annual filing
Facade inspection report (Cycle 10C) Applies
Local Law 11 / FISP · Feb 21, 2027 to Feb 21, 2029
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 1, 2 or 3 are in sub-cycle 10C. Agency page

Feb 21, 2029
in 841 days
Filing window not open yet
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 2 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1154 days
Next cycle year 2029
Energy audit and retro-commissioning (2032) Likely applies
Local Law 87 · Calendar year 2032
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 2062). Agency page

Dec 31, 2032
in 2250 days
Next due 2032

Open violations

ECB / OATH (21) · $92,500 owed
IssuedViolationHearingBalance
May 9, 2026Unknown CLASS - 2
MOBILE CRANE CD-5229, CN-793/25 WAS OPERATING ON SITE. THE EQUIPMENT USER FAILED TO NOTIFY THE DEPARTMENT OF THE CRANE'S ARRIVAL TO SITE. EQUIPMENT USER IS RESPONSIBLE TO NOTIFY THE DEPARTMENT ABOUT CRANE THAT
#39189470J
Mar 30, 2027
$5,000
May 9, 2026Unknown CLASS - 2
MOBILE CRANE CD-5800, CN-794/25 WAS OPERATING ON SITE. THE EQUIPMENT USER FAILED TO NOTIFY THE DEPARTMENT OF THE CRANE'S ARRIVAL TO SITE. EQUIPMENT USER IS RESPONSIBLE TO NOTIFY THE DEPARTMENT ABOUT CRANE THAT
#39189469M
Mar 30, 2027
$5,000
Apr 10, 2026Unknown CLASS - 2
DURING MY INSPECTION AND UPON REVIEWING DOB NOW AND BIS SYSTEM REVEALS SSM / SSC ON MULTIPLE PERMIT AND NB NOT IN COMPLIANCE TO CODE BC 3310.5.4 STOP ALL WORK UNDER APPLICATION B01083521-I1-GC EXCEPT TO UPDATE
#39552848X
May 25, 2027
DEFAULT
$5,000
Jan 22, 2026Construction CLASS - 1
FAILURE TO INSTITUTE/MAINTAIN SAFETY EQUIPMENT MEASURES OR TEMPORARY CONSTRUCTION-NO HANDRAILS. AT THE TIME OF MY INSPECTION OF A 30-STORY NEW BUILDING WITH ACTIVE CONSTRUCTION OPERATIONS. I OBSERVED THE STAIRW
#39549397Z
Nov 20, 2026
$2,500
Jan 22, 2026Unknown CLASS - 2
BC 3314.1 30-STORY NEW BUILDING WITH ACTIVE CONSTRUCTION OPERATIONS, I OBSERVED PIPE SCAFFOLD AT EXP# 1 NOT MAINTAINED, INCLUDING LOOSE PLANKS, MISSING PINS, MISSING GUARDRAILS, AND DEBRIS NETTING WITH LARGE O
#39549426Z
Nov 20, 2026
$2,500
Jan 22, 2026Construction CLASS - 1
FAILURE TO INSTITUTE/MAINTAIN SAFETY EQUIPMENT MEASURES OR TEMPORARY CONSTRUCTION-NO GUARD RAILS. AT THE TIME OF MY INSPECTION OF A 30-STORYNEW BUILDING WITH ACTIVE CONSTRUCTION OPERATIONS, I OBSERVED WINDOW OP
#39549398K
Nov 20, 2026
$5,000
Jan 12, 2026Unknown CLASS - 1
3308.10 NO CONTROL ACCESS ZONE NOTE: AT TIME OF INSPECTION OF INSPECTION 30 STORY NEW BUILDING, I OBSERVED ONGOING STRIPPING OPERATION ON THE 28 FLOOR WITHOUT THE REQUIRED CONTROL ACCESS ZONE IN PLACE, CREATING
#39549034J
Nov 19, 2026
$5,000
Jan 12, 2026Unknown CLASS - 1
3308.6.1.4 ALTERNATIVE SYSTEMS NOTE: AT TIME OF INSPECTION OF AN 30 STORY NB BUILDING, I OBSERVED ONGOING CONCRETE AND STRIPPING OPERATIONS WITH ALTERNATED HORIZONTAL NETTING SYSTEM NOT IN PLACE FROM THE 28 TO
#39549035L
Nov 19, 2026
$5,000
Dec 1, 2025Construction CLASS - 1
FAILURE TO COMPLY WITH SHORING DESIGN DRAWING ON 22ND FLOOR CANTILEVER ELEVATION AS ALL BEAMS AND SHORING / RESHORING WASN'T SECURED WITH ANCHOR RODS ALSO THE POSTS WASN'T SECURE TO BEAMS, CREATING IMMEDIATE HA
#39547491X
Apr 8, 2027
$2,500
Nov 17, 2025Construction CLASS - 1
AT TIME OF INSPECTION, OBSERVED CONSTRUCTION WORK PERFORMED CONTRARY TO STOP WORK ORDER UNDER COMPLAINT #3A37233. CONTRARY TO AC 28-207.2.2. CONTINUING WORK UNDER A STOP WORK ORDER COMPROMISES DOB OVERSIGHT AND
#39547025Z
Apr 8, 2027
$10,000
Nov 13, 2025Unknown CLASS - 1
AT TIME OF INSPECTION, OBSERVED DESIGNATED CS LIC #31331 HAS NOT PERFORMED REQUIRED DUTIES SINCE 09/27/25 AND CONTINUES TO SIGN AS COMPETENT PERSON. LOG BOOK SHOWS LIC #30755 AND #31545 ACTING AS CS WITHOUT DES
#39546955K
Sep 8, 2026
IN VIOLATION
$5,000
Nov 13, 2025Unknown CLASS - 1
AT TIME OF INSPECTION, OBSERVED CONSTRUCTION SUPERINTENDENT PERFORMING DUTIES OF FIRE SAFETY MANAGER. CONTRARY TO BC 3301.1.2 & FC 1408, A SEPARATE CERTIFIED FIRE SAFETY MANAGER IS REQUIRED WHERE A SITE SAFETY
#39546956M
Mar 16, 2027
$5,000
Nov 13, 2025Construction CLASS - 1
AT TIME OF INSPECTION, OBSERVED WORKERS PERFORMING LEADING-EDGE OPERATIONS WITHOUT REQUIRED FALL PROTECTION OR PERIMETER SAFEGUARDS. CONTRARY TO BC 3301.2, & 3308.7. FAILURE TO MAINTAIN PROTECTION CREATED IMMED
#39546951N
Apr 8, 2027
$10,000
Nov 13, 2025Unknown CLASS - 1
AT TIME OF INSPECTION, OBSERVED CONSTRUCTION SUPERINTENDENT PERFORMING DUTIES OF FIRE SAFETY MANAGER. CONTRARY TO BC 3301.1.2 & FC 1408, A SEPARATE CERTIFIED FIRE SAFETY MANAGER IS REQUIRED WHERE A SITE SAFETY
#39546946Z
Apr 8, 2027
$5,000
Oct 13, 2025Unknown CLASS - 2
NOTE: AT TIME OF INSPECTION, I OBSERVED A SUPPORTED SCAFFOLD IN PLACE WITH A BLUE PROHIBITED SIGN POSTED ON THE DEBRIS NETTING CONTRARY TO CODE 3314.1. DISCONTINUE POSTING OF ALL PROHIBITED SIGNS.
#39545922J
Jan 21, 2027
$2,500
Sep 27, 2025Construction CLASS - 2
OBSERVED JERSEY BARRIERS OCCUPYING ROADWAY EXP#1 NOT INTERLOCKED AS PER MANUFACTURES SPECIFICATION THIS POSES A POTENTIAL HAZARD BY ALLOWING UNINTENDED MOVEMENT OF THE BARRIERS INCREASING THE RISK OF DISPLACEME
#39545403H
Mar 4, 2027
$1,250
Aug 4, 2025Construction CLASS - 1
TIME OF INSPECTION OF A PROPOSED 30 STORIES BUILDING UNDER CONSTRUCTION AT 13TH FLOOR FRAMING LEVEL APPROXIMATELY 130 FEET IN HEIGHT, INSPECTION REVEALS THAT THE HOIST WAS NOT IN STATE OF READINESS AS THE BUILD
#39543211Y
Dec 4, 2026
$2,500
Aug 4, 2025Construction CLASS - 1
TIME OF INSPECTION OF A PROPOSED 30 STORIES BUILDING UNDER CONSTRUCTION AT 13TH FLOOR FRAMING LEVEL APPROXIMATELY 130 FEET IN HEIGHT, INSPECTION REVEALS THAT THE HOIST WAS NOT IN STATE OF READINESS AS THE BUILD
#39543210M
Jan 5, 2027
$2,500
Aug 1, 2025Unknown CLASS - 2
BC3303.12.2 AT TIME OF INSPECTION OF A PROPOSED 30 STORIES BUILDING AT 13 FLOOR FRAMING LEVEL APPROXIMATELY 130 FEET IN HEIGHT , I OBSERVED THERE WAS NO HOIST FOR THE CONSTRUCTION ACTIVITIES IN THE BUILDING AN
#39543156K
Jan 5, 2027
$2,500
Jul 31, 2025Unknown CLASS - 2
BC 3308.6 AT TIME OF INSPECTION OF A NEW BUILDING CONSTRUCTION AT 13 FLOOR FRAMING LEVEL APPROXIMATELY 163 FEET IN HEIGHT , I OBSERVED AT EXPOSURE # 2 MISSING HORIZONTAL SAFETY NETTING FOR PROTECTION AS REQUI
#39543102P
Jan 5, 2027
$2,500
Mar 28, 2023Construction CLASS - 1
BUILDING OR OPEN LOT OCCUPIED WITHOUT A VALID C OF O. THE BUILDING DEPT RECORDS PRIMARY STRUCTURE DEMOLISHED UNDER PERMITTED APPLICATION #302255306 & SIGNED OF 10/28/09 RENDERING LOT VACANT. ATO INSPECTION OBSE
#39082445H
Jun 7, 2023
DEFAULT
$6,250
DOB (0)

None open.

DOB NOW Safety (0)

None open.

HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 3, 2026, 9:00 PM ET. BBL 3020620024.