Manhattan · Block 742 · Lot 35 · 10011

163 8 Avenue

3 floors · 3 apartments · 4,198 sq ft · built 1901 · class S3 · owner of record: L&E Brokerage Inc

13open violations
$3,810ECB/OATH penalties owed
10HPD class C (immediately hazardous)
60dto Gas piping inspection (2026 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 4 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 60 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 60 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 60 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 76 days
Annual
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 304 days
Registered through 2027-09-01

Open violations

ECB / OATH (3) · $3,810 owed
IssuedViolationHearingBalance
Dec 16, 2025Construction CLASS - 2
FAILURE TO SUBMIT CERTIFICATE OF CORRECTION FOR VIOLATION # 39131449N ISSUED ON 11/27/2024 FOR TAMPERED WITH, REMOVED OR DEFACED A WRITTEN POSTED STOP WORK ORDER., FILE A CERTIFICATE OF CORRECTION
#39170644K
Jan 14, 2027
DEFAULT
$1,280
Dec 16, 2025Construction CLASS - 1
FAILURE TO SUBMIT CERTIFICATE OF CORRECTION FOR VIOLATION # 39124056M ISSUED ON 09/16/2024 FOR WORK WITHOUT PERMIT, COMPLY WITH COMMISSIONER'S ORDER
#39170643Z
Jan 14, 2027
DEFAULT
$2,530
Nov 27, 2024Construction CLASS - 1
AT TIME OF INSPECTION OBSERVED WRITTEN POSTED STOP WORK ORDER WAS TAMPERED WITH AND DEFACED THAT WAS POSTED ON FRONT ENTRY DOOR ON 9/16/24 WITH EVIDENCE ON DOB RECORD FILE. (RE-POSTED OF WRITTEN SWO COMPLETED O
#39131449N
Jan 21, 2026
IN VIOLATION
$0
DOB (0)

None open.

DOB NOW Safety (1)
IssuedViolationStatus
Oct 31, 2025Gas Piping - LL152 FTF-PL-PER
Cycle 1, Sub-cycle C (premises is in Community District 4)
Active
HPD (10) · C 10 · B 0 · A 0
IssuedClassViolationCorrect by
Apr 26, 2021CApt 3 · § 27-2073 ADM CODE - PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 3, 3rd STORY, 1st APARTMENT FROM NORTH AT EASTMay 2, 2021
Jan 22, 2021CApt 3 · § 27-2073 ADM CODE - PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 3, 2nd STORY, 1st APARTMENT FROM SOUTH AT WESTJan 28, 2021
Dec 14, 2020CApt 3 · § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 3, 3rd STORY, 1st APARTMENT FROM NORTH AT EASTDec 11, 2020
Nov 24, 2020CApt 2 · § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE 1st ROOM FROM NORTH LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM WEST AT NORTHNov 24, 2020
Nov 24, 2020C§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED, AT BASEMENT AT BOILER ROOMNov 30, 2020
Nov 24, 2020C§ 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM NO SIGN PRSENT AT PUBLIC HALL, 1st STORYNov 30, 2020
Nov 24, 2020CApt 2 · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES NO GAS FOR COOKING IN THE KITCHEN LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM WEST AT NORTHNov 30, 2020
Nov 16, 2020CApt 3 · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 3, 2nd STORY, 1st APARTMENT FROM WEST AT NORTHNov 14, 2020
Nov 16, 2020C§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM BASEMENT DOOR LOCKED AT BOILER ROOMNov 22, 2020
Nov 16, 2020CApt 3 · § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 3, 2nd STORY, 1st APARTMENT FROM WEST AT NORTHNov 14, 2020

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 31, 2026, 5:52 PM ET. BBL 1007420035.