3 floors · 48,960 sq ft · built 1960 · class W2 · owner of record: R C Ch Our Lady Of As
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 62 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 48,960 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 183 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 183 days | Annual filing |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 10 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 793 days | Next cycle year 2028 |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-01-09 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Feb 10, 2022 | Construction CLASS - 1 AT TIME OF MY INSPECTION I OBSERVED IN THE CELLAR NEW GAS PIPING TO AND HOT WATER HEATER INSTALLED WITHOUT A PERMIT. 100% OF THE WORK IS COMPLETE. CEASE USE ON UN PERMITTED HOT WATER HEATER ON 02/10/2022 WILL R #39055909N | Apr 1, 2022 IN VIOLATION | $0 |
| Feb 10, 2022 | Plumbing CLASS - 1 AT TIME OF MY INSPECTION I OBSERVED IN THE CELLAR NEW GAS PIPING INSTALLED THAT HAS NOT BEEN TESTED., PERFORM TEST #39055911M | Apr 1, 2022 IN VIOLATION | $0 |
| Feb 10, 2022 | Construction CLASS - 1 AT TIME OF MY INSPECTION I OBSERVED IN THE CELLAR DOUBLE GAS VALVES INSTALLED ON THE GAS PIPING TO THE WATER HEATER THAT IS NOT CODE COMPLIANT AS ONLY 1 GAS VALVE SHOULD BE INSTALLED ONLY., REPAIR AND/REPLACE #39055910K | Apr 1, 2022 IN VIOLATION | $0 |
| Feb 10, 2022 | Plumbing CLASS - 1 AT TIME OF MY INSPECTION I OBSERVED IN THE CELLAR, GAS BEING SUPPLIED TO THE BUILDING WITHOUT DOB AUTHORIZATION AFTER NEW GAS PIPING WAS INSTALLED WITHOUT A PERMIT., FILE FOR REQUIRED PERMITS AND HAVE NECESSARY #39055912Y | Apr 1, 2022 IN VIOLATION | $0 |
| Jun 14, 2019 | Construction CLASS - 1 AS PER ONE AO SMITH WATER HEATER. SERIAL#1345A025095. DATE BUILT, 11/11/2013. WORK W/O A PERMIT., OBTAIN PERMIT; APPLY FOR PROPER PERMITS, CORRECT ALL VIOLATING CONDITIONS AND CALL FOR AN INSPECTIONS. #39004178Z | Aug 2, 2019 DEFAULT | $0 |
| Issued | Violation | Status |
|---|---|---|
| May 11, 2022 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00270 | DOB VIOLATION - ACTIVE |
| May 11, 2022 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00271 | DOB VIOLATION - ACTIVE |
| May 11, 2022 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00272 | DOB VIOLATION - ACTIVE |
| May 11, 2022 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00273 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Jan 8, 2026 | Gas Piping - LL152 FTF-PL-PER Cycle 2, Sub-cycle A (premises is in Community District 10) | Active |
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2020 External Inspection Affirmation of Correction for LP Device | Active |
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2018 External Inspection Affirmation of Correction for LP Device | Active |
| May 11, 2022 | AEUHAZ FTC-AEU-HAZ | Active |
| May 11, 2022 | AEUHAZ FTC-AEU-HAZ | Active |
| May 11, 2022 | AEUHAZ FTC-AEU-HAZ | Active |
| May 11, 2022 | AEUHAZ FTC-AEU-HAZ | Active |
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)