3 floors · 4 apartments · 4,750 sq ft · built 1931 · class S4 · owner of record: Aleyda Ramirez
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 2026-09-01 |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 62 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 62 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 78 days | Annual |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 3 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 793 days | Next cycle year 2028 |
None open.
| Issued | Violation | Status |
|---|---|---|
| Jan 16, 2001 | CONSTRUCTION WORK WITHOUT A PERMIT. WORK NOTED: AN OPENING APPROX 3'X 3'6" WAS CONSTRUCTED AT THE REAR WALL AND AIR-CONDITIONING UNIT WAS INSTALLED REMEDY: OBTAIN PERMIT #03AS04 | VIOLATION WORK WITHOUT PERMIT - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Jan 8, 2026 | Gas Piping - LL152 FTF-PL-PER Cycle 2, Sub-cycle A (premises is in Community District 3) | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| May 6, 2026 | A | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. | Aug 9, 2026 |
| Jun 11, 2025 | A | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. | Sep 14, 2025 |
| Apr 12, 2024 | A | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. | Jul 16, 2024 |
| Mar 27, 2023 | A | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. | Jun 30, 2023 |
| Oct 13, 2009 | B | SECTION 27-2040 ADM CODE PROVIDE ADEQUATE LIGHTING AT OR NEAR THE OUTSIDE OF THE FRONT ENTRANCEWAY OF THE BUILDING AND KEEP SAME BURNING FROM SUNSET EVERY DAY TO SUNRISE ON THE DAY FOLLOWING , 100 WATTS REQUIRED. | Nov 17, 2009 |
| Jun 10, 2008 | A | D26-10.01 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE BROKEN WOOD CORNICE AT ROOF FRONT NORTH SIDE. | Sep 13, 2008 |
| Jun 10, 2008 | A | D26-10.01 ADM CODE REPLACE WITH NEW THE BROKEN, DEFECTIVE GLASS WINDOWS OF STORE FRONT NORTHEAST CORNER. | Sep 13, 2008 |
| Jun 10, 2008 | A | D26-10.01 ADM CODE REPLACE WITH NEW THE BROKEN, DEFECTIVE GLASS WINDOW 1 STY STORE EXTENSION WEST. | Sep 13, 2008 |
| Jun 10, 2008 | A | D26-10.01 ADM CODE REPLACE WITH NEW THE BROKEN, DEFECTIVE PLASTER BOARD CELLAR CEILING THROUGHOUT. | Sep 13, 2008 |
| Jun 10, 2008 | A | D26-19.07 ADM CODE PROVIDE ADEQUATE LIGHTING AT OR NEAR THE OUTSIDE OF THE FRONT ENTRANCEWAY OF THE BUILDING AND KEEP SAME BURNING FROM SUNSET EVERY DAY TO SUNRISE ON THE DAY FOLLOWING AT FRONT OF BUILDING. SURVEY | Sep 13, 2008 |
| Jun 10, 2008 | B | D26-10.01 ADM CODE REPLACE WITH NEW THE MISSING CEILING LIGHT FIXTURE VESTIBULE 1 STY PUBLIC HALL. | Jul 15, 2008 |
| Jun 10, 2008 | B | Apt 2 · D26-10.01 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE BELLS 1 TO 2 STY APT 2. , SECTION '' '' | Jul 15, 2008 |
| Jun 10, 2008 | B | SECTION 27-2040 ADM CODE PROVIDE ADEQUATE LIGHTING AT OR NEAR THE OUTSIDE OF THE FRONT ENTRANCEWAY OF THE BUILDING AND KEEP SAME BURNING FROM SUNSET EVERY DAY TO SUNRISE ON THE DAY FOLLOWING 100 WATTS NIGHT INSPECTION. | Jul 15, 2008 |
| Jun 10, 2008 | B | SECTION 27-2039 ADM CODE PROVIDE ADEQUATE LIGHT OF NOT LESS THAN 60 WATTS INCANDESCENT OR EQUIVALENT ILLUMINATION VESTIBULE 1 STY NIGHT INSPECTION. | Jul 15, 2008 |
| Jun 10, 2008 | B | SECTION 27-2005 ADM CODE REPLACE WITH NEW THE MISSING LIGHT FIXTURE VESTIBULE 1 STY. | Jul 15, 2008 |
| Jun 10, 2008 | B | SECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF EXPOSED ELECTRICAL WIRES CEILING VESTIBULE 1 STY. | Jul 15, 2008 |
| Jun 10, 2008 | A | SECTION 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX MISSING. | Sep 13, 2008 |
| Jun 10, 2008 | A | SECTION 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR FRAME MISSING. | Sep 13, 2008 |
| Jun 10, 2008 | B | SECTION 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. MAKE STATIONARY THE IRON LADDER LEADING TO SCUTTLE OPENING IN ROOF 4 STY PUBLIC HALL. | Jul 15, 2008 |
| Jun 10, 2008 | A | SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDING PLASTER COCKLOFT 4 STY PUBLIC HALL. | Sep 13, 2008 |
| Jun 10, 2008 | A | SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE MAILBOXES 1 STY PUBLIC HALL VESTIBULE. | Sep 13, 2008 |
| Jun 10, 2008 | B | SECTION 27-2005 ADM CODE REPLACE WITH NEW THE MISSING BALUSTERS 4 STY PUBLIC HALL BALUSTRADE. | Jul 15, 2008 |
| Jun 10, 2008 | B | Apt 2F · SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE 2 STY FRONT APT 2F ROMAN. LOCATED AT APT 2F | Jul 15, 2008 |
| Jun 10, 2008 | A | D26-10.01 ADM CODE REPLACE WITH NEW THE MISSING BRICKS UNDER RAIN GUTTER ROOF REAR. | Sep 13, 2008 |
| Feb 23, 2006 | B | Apt 3R · SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE WINDOW COUNTER BALANCE, IN THE KITCHEN LOCATED AT APT 3R, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST | Apr 4, 2006 |
| Feb 23, 2006 | B | Apt 3R · SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE WINDOW COUNTER BALANCE ,TOTAL OF 5 IN THE ENTIRE APARTMENT LOCATED AT APT 3R, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST | Apr 4, 2006 |
| Feb 23, 2006 | B | Apt 3R · SECTION 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 3R, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST | Apr 4, 2006 |