7 floors · 52 apartments · 58,810 sq ft · built 1916 · class D6 · owner of record: Amsterdam 140 Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 9 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 47 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 47 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 47 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 63 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 58,810 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 168 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 168 days | Annual filing |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 291 days | Registered through 2027-09-01 |
| Energy audit and retro-commissioning (2031) Likely applies Local Law 87 · Calendar year 2031 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 2071). Agency page | Dec 31, 2031 in 1873 days | Next due 2031 |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-02-27 (Accepted). Agency page | On file | 2026 reports accepted |
| Facade inspection report (Cycle 10C) Applies Local Law 11 / FISP · Feb 21, 2027 to Feb 21, 2029 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 1, 2 or 3 are in sub-cycle 10C. DOB facade records for this building show $3,746,380 in late-filing or failure-to-file penalties. Agency page | On file | Cycle 10 filing on record: SWARMP (2026-11-04) |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Apr 8, 2025 | Local Law CLASS - 2 FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 9C REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL #906990. REMEDY: SUBMIT ACCEPTABLE REQU #37034719R | Jun 2, 2026 IN VIOLATION | $0 |
| Dec 3, 2024 | Construction CLASS - 1 FAILURE TO MAINTAIN EXTERIOR AND APPURTENANCES. NOTES: CRACKED/SPALLING TERRA-COTTA AT PARAPET LEVEL AT EXPOSURE #1 NORTH AND EXPOSURE #3 SOUTH ELEVATION. NO SAFETY MEASURE IN PLACE. REMEDY: MAINTAIN FACADE. #35689250N | Dec 5, 2025 IN VIOLATION | $0 |
| Sep 24, 2024 | Construction CLASS - 2 ATOI FAILURE TO FILE CERTIFICATE OF CORRECTION FOR OATH SUMMONS #39110607R - SERVED 4-3-2024 - FIRST HEARING DATE 6-13-2024 - FOUND IN VIOLATION - NO COMPLIANCE RECORDED, FILE A CERTIFICATE OF CORRECTION; FILE #39125610J | Dec 5, 2024 IN VIOLATION | $0 |
| Sep 24, 2024 | Construction CLASS - 2 ATOI WATER DAMAGE AT CEILING OF CLOSET AT APT #7E ON 7TH FLOOR OF PREMISES, REPAIR AND/OR REPLACE; REPAIR WATER DAMAGE AT CLOSET CEILING AT APT #7E AT 7TH FLOOR OF PREMISES #39125611L | Dec 5, 2024 IN VIOLATION | $0 |
| Jun 17, 2024 | Unknown CLASS - 2 I OBSERVED THROUGHOUT THE ENTIRE HALLWAY FLOORS 1-7 NEW INSTALLATION OF 35 LIGHT FIXTURES AND BRANCH WIRING. NO APPLICATION ON FILE WITH D.O.B., OBTAIN PERMIT #39117109X | Jan 23, 2025 IN VIOLATION | $0 |
| Apr 3, 2024 | Construction CLASS - 2 ATOI, AT BULKHEAD AT ROOF OF PREMISES, AN OCCUPIED 7 STORY 53 A UNIT MIXED USE MULTIPLE DWELLING, 2 SQUARE FEET OF WATER DAMAGE AND ACTIVE WATER LEAK AT CEILING, REPAIR AND/OR REPLACE; REPAIR CEILING AND ROOF A #39110607R | Jun 13, 2024 IN VIOLATION | $0 |
| Jun 21, 2017 | Construction CLASS - 2 FAILURE TO MAINTAIN EXTERIOR BLDG AND APPURTENANCES. NOTE: NORTH ELEVATION EXP#1 BRICKS AND STONES OBSERVED AT 2ND FLR WINDOW SILL.SOUTH ELEVATION EXP#3 WOOD PROTRUDING OFF AT 3RD FLR WINDOW SILL.ROOF ELEVA #35253948H | Aug 10, 2017 IN VIOLATION | $0 |
| Nov 9, 2015 | Plumbing CLASS - 2 FAILURE TO MAINTAIN BLDG IN A CODE COMPLIANT MANNER. EXHAUST DISCHARGED MUST BE NO CLOSER THAN 10FT FROM BLDG OPENINGS AS PER RS2-2.1.4 & MC 401.5.2. NOTED: AT FRONT ENTRANCE OF 500 W 140TH ST EXHAUST VENT FROM #35154287X | May 5, 2016 ADMIT/IN-VIO | $0 |
| Nov 9, 2015 | Construction CLASS - 2 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. NOTED: COOKING EXHAUST NOT PROPERLY VENTED EXHAUST VENT AT 2ND FL WINDOW DISCHARGING FUMES (AZAR) FRONT ENTRANCE OF 500 W 140TH ST. REMEDY: REPAIR &/OR REPLACE #35154286Y | May 5, 2016 ADMIT/IN-VIO | $0 |
| May 29, 2015 | Local Law CLASS - 2 FAILURE TO FILE AN ACCEPTABLE AMENDED CYCLE 7 REPORT TO THIS DEPARTMENT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL LOCAL LAW FISP REPORT.REM:FILE AN AMENDED REPORT FOLLOWING REMEDIAL REPAIR #36027535K | Feb 18, 2016 IN VIOLATION | $0 |
| Mar 11, 2014 | Elevators CLASS - 1 58I10 - MOTOR GEAR SMOKING AND RUNNING HOT REPAIR AND CALL FOR CEASE USE LIFT. ALSO MAKING ALOT OF NOISE. (212) 566-5232 #38230487L | May 1, 2014 WRITTEN OFF | $0 |
| Mar 28, 2008 | Construction Non-Hazardous WORK W/O A PERMIT. WORK NOTED: AT BASEMENT WORK BEING DONE CREATING 2 DWELLINGS. COMPLETE GUT OF INTERIOR ON SOUTH SIDE BASEMENT, ON NORTH NEW PARTITIONS & SHEETROCK INSTALLED. BATHROOM COMPLETELY GUTTED. #34618870J | May 22, 2008 STIPULATION/IN-VIO | $0 |
| Aug 8, 2007 | Construction Non-Hazardous WORK W/O A PERMIT. WORK NOTED:COMPLETE REHAB.NEW 2 X 4" WOOD STUDS PARTITIONS ERECTED FROM FL TO CEILING. NEW DROP CEILING, NEW FLOORING,NEW BATHROOM & KITCHEN. 3RD FL NEXT TO 3G N/W APT AND 3C N.E #34587133K | Sep 27, 2007 DEFAULT | $0 |
| Nov 13, 1998 | Construction Non-Hazardous WORK W/O A PERMIT. NOTED: AN ILLUMINATED AWNING SIGN INSTALLED W/ WORDING "FOOD CORP" APPROX SIZE 35'X3' AT 12' ABOVE SIDEWALK. A WALL SIGN ERECTED FIXED TO WALL APPROX SIZE 3'X24'. REMEDY: OBTAIN PERMITS #34190932L | Jun 17, 1999 WRITTEN OFF | $0 |
| Feb 19, 1992 | Construction Non-Hazardous WORK WITHOUT A PERMIT IN THAT THE BASEMENT HAS AT LEAST TWO APARTMENTS CONSTRUCTED AT THE EAST SIDE. REMEDY: OBTAIN NECESSARY PERMITS, IF FEASIBLE, OR RESTORE PREMISES TO PRIOR LEGAL CONDITION. #34065668Z | May 7, 1992 WRITTEN OFF | $0 |
| Feb 19, 1992 | Construction Non-Hazardous WORK WITHOUT A PERMIT IN THAT 5 WINDOWS AT THE BASEMENT LEVEL AND 5 WINDOWS AT THE FIRST FLOOR LEVEL IN VARIOUS LOCATIONS HAVE BEEN CLOSED UP WITH WOOD OR MASONRY, REDUCING THE AMOUNT OF AVAILABLE NATURAL LIGHT #34065674P | May 7, 1992 WRITTEN OFF | $0 |
| Feb 19, 1992 | Construction Non-Hazardous OCCUPANCY CONTRARY TO BUILDING DEPT. RECORDS IN THAT THE BASEMENT IS BEING OCCUPIED BY AT LEAST TWO APARTMENTS AT THE EAST SIDE OF THE BASEMENT. REMEDY: DISCONTINUE ILLEGAL USE. OBTAIN A NEW CERTIFICATE OF OCCU #34065667R | May 7, 1992 WRITTEN OFF | $0 |
| Issued | Violation | Status |
|---|---|---|
| Mar 5, 2025 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00072 | DOB VIOLATION - ACTIVE |
| Feb 22, 2024 | NO REPORT AND / OR LATE FILING (FACADE) FAILED TO FILE FISP CYCLE 9C TECHNICAL REPORT BY 2/21/2024 #00434 | DOB VIOLATION - ACTIVE |
| Feb 17, 2020 | FACADE SAFETY PROGRAM #HAZ88663 | DOB VIOLATION - ACTIVE |
| May 5, 2008 | CONSTRUCTION #09AM01 | VIOLATION WORK WITHOUT PERMIT - ACTIVE |
| Jan 13, 1997 | LOCAL LAW 10/81 - ELEVATOR #01745 | DOB VIOLATION - ACTIVE |
| Sep 25, 1991 | CONSTRUCTION #D3SI01 | VIOLATION UNSERVED ECB-ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Mar 5, 2025 | AEUHAZ FTC-AEU-HAZ | Active |
| Feb 22, 2024 | Facades FISPNRF FAILED TO FILE FISP CYCLE 9C TECHNICAL REPORT BY 2/21/2024 | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction | Active |
| Feb 17, 2020 | Facades FISP CYCLE 8C UNSAFE REPORT FILED | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Oct 9, 2026 | B | Apt 7E · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT EAST WALL IN THE 3rd ROOM FROM NORTH LOCATED AT APT 7E, 7th STORY, 1st APARTMENT FROM SOUTH AT WEST | Nov 13, 2026 |
| Oct 9, 2026 | B | Apt 7E · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER THE CIEILING IN THE 2nd ROOM FROM NORTH LOCATED AT APT 7E, 7th STORY, 1st APARTMENT FROM SOUTH AT WEST | Nov 13, 2026 |
| Oct 9, 2026 | B | Apt 7E · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AT EAST CLOSET IN THE 2nd ROOM FROM NORTH LOCATED AT APT 7E, 7th STORY, 1st APARTMENT FROM SOUTH AT WEST | Nov 13, 2026 |
| Oct 9, 2026 | B | Apt 7E · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT EAST WALL IN THE 3rd ROOM FROM NORTH LOCATED AT APT 7E, 7th STORY, 1st APARTMENT FROM SOUTH AT WEST | Nov 13, 2026 |
| Oct 9, 2026 | A | Apt 7E · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQFT AT THE EAST CLOSET CEILING IN THE 2nd ROOM FROM NORTH LOCATED AT APT 7E, 7th STORY, 1st APARTMENT FROM SOUTH AT WEST | Jan 12, 2027 |
| Oct 9, 2026 | B | Apt 7E · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE 2nd ROOM FROM NORTH LOCATED AT APT 7E, 7th STORY, 1st APARTMENT FROM SOUTH AT WEST | Nov 13, 2026 |
| Sep 23, 2026 | B | Apt 7E · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND EAST WALL INSIDE CLOSET AT NORTH WALL IN THE 2nd ROOM FROM NORTH LOCATED AT APT 7E, 7th STORY, 2nd APARTMENT FROM EAST AT SOUTH | Oct 28, 2026 |
| Sep 23, 2026 | A | Apt 7E · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN TEN SQUARE FEET AT CEILING AND EAST WALL INSIDE CLOSET AT NORTH WALL IN THE 2nd ROOM FROM NORTH LOCATED AT APT 7E, 7th STORY, 2nd APARTMENT FROM EAST AT SOUTH | Dec 27, 2026 |
| Sep 22, 2026 | B | Apt 7E · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT SOUTH WALL IN THE 3rd ROOM FROM NORTH LOCATED AT APT 7E, 7th STORY, 2nd APARTMENT FROM EAST AT SOUTH | Oct 27, 2026 |
| Sep 22, 2026 | B | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE COUNTER BALANCE AT LOWER WINDOW SASH AT 3RD WINDOW FROM WEST AT SOUTH WALL. AT PUBLIC HALL, 7th STORY | Oct 27, 2026 |
| Aug 20, 2026 | C | Apt 5A · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 5A, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH | Sep 15, 2026 |
| Apr 29, 2026 | A | (A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS. | Aug 2, 2026 |
| Jan 23, 2025 | C | Apt 2A · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT DOOR LEADING TO PUBLIC HALLWAY FIRE STAIRS AT NORTH WALL IN THE KITCHEN LOCATED AT APT 2A, 2nd STORY, 1st APARTMENT FROM EAST AT SOU | Feb 6, 2025 |
| Jan 23, 2025 | C | Apt 2A · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2A, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION AT EAST | Feb 18, 2025 |
| Dec 5, 2024 | B | Apt 4H · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE HARDWOOD FLOOR IN THE 2nd ROOM FROM NORTH LOCATED AT APT 4H, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Jan 9, 2025 |
| Dec 5, 2024 | B | Apt 4H · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... MORE THAN 10 SQ FEET AT CEILING IN THE BATHROOM LOCATED AT APT 4H, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Jan 9, 2025 |
| Dec 5, 2024 | B | Apt 4H · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE HARDWOOD FLOOR IN THE 3rd ROOM FROM NORTH LOCATED AT APT 4H, 4th STORY, 1st APARTMENT FROM WEST AT NORTH | Jan 9, 2025 |
| Nov 15, 2023 | B | Apt 2A · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROXIMATELY 4 SQ.FT AT CEILING, 4 SQ.FT AT NORTH WALL, 3 SQ.FT AT SOUTH WALL AND 3 SQ.FT AT WEST WALL IN THE BATHROOM LOCATED AT APT 2A, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''EAST'' | Dec 20, 2023 |
| Nov 15, 2023 | C | Apt 2A · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2A, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''EAST'' | Dec 11, 2023 |
| Nov 15, 2023 | C | Apt 2A · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT FIRE DOOR LEADING TO PUBLIC HALL AT NORTH WALL IN THE KITCHEN LOCATED AT APT 2A, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTI | Nov 29, 2023 |
| Nov 15, 2023 | B | Apt 2A · § 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM WINDOW TO FIRE ESCAPE OR PROVIDE APPROVED TYPE GATE IN THE KITCHEN LOCATED AT APT 2A, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''EAST '' | Dec 20, 2023 |
| Nov 15, 2023 | B | Apt 2A · § 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM WINDOW TO FIRE ESCAPE OR PROVIDE APPROVED TYPE GATE IN THE 3rd ROOM FROM NORTH LOCATED AT APT 2A, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''EAST '' | Dec 20, 2023 |
| Aug 26, 2015 | B | Apt 2A · § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2A, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH | Sep 30, 2015 |
| Date | Source | What | Now |
|---|---|---|---|
| Oct 9, 2026 | HPD B | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT EAST WALL IN THE 3rd ROOM FROM NORTH LOCATED AT APT 7E, 7th STORY, 1st APARTMENT FROM SOUTH AT WEST | Open |
| Oct 9, 2026 | HPD B | § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER THE CIEILING IN THE 2nd ROOM FROM NORTH LOCATED AT APT 7E, 7th STORY, 1st APARTMENT FROM SOUTH AT WEST | Open |
| Oct 9, 2026 | HPD B | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AT EAST CLOSET IN THE 2nd ROOM FROM NORTH LOCATED AT APT 7E, 7th STORY, 1st APARTMENT FROM SOUTH AT WEST | Open |
| Oct 9, 2026 | HPD B | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT EAST WALL IN THE 3rd ROOM FROM NORTH LOCATED AT APT 7E, 7th STORY, 1st APARTMENT FROM SOUTH AT WEST | Open |
| Oct 9, 2026 | HPD A | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQFT AT THE EAST CLOSET CEILING IN THE 2nd ROOM FROM NORTH LOCATED AT APT 7E, 7th STORY, 1st APARTMENT FROM SOUTH AT WEST | Open |
| Oct 9, 2026 | HPD B | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE 2nd ROOM FROM NORTH LOCATED AT APT 7E, 7th STORY, 1st APARTMENT FROM SOUTH AT WEST | Open |
| Oct 8, 2026 | HPD B | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT EAST WALL AND CEILING IN THE 3rd ROOM FROM NORTH LOCATED AT APT 7E, 7th STORY, 1st APARTMENT FROM SOUTH AT WEST | Closed |
| Oct 8, 2026 | HPD A | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10SQ FT AT CEILING IN CLOSET IN THE 2nd ROOM FROM NORTH LOCATED AT APT 7E, 7th STORY, 1st APARTMENT FROM SOUTH AT WEST | Closed |
| Oct 8, 2026 | HPD B | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 2nd ROOM FROM NORTH LOCATED AT APT 7E, 7th STORY, 1st APARTMENT FROM SOUTH AT WEST | Closed |
| Sep 23, 2026 | HPD B | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND EAST WALL INSIDE CLOSET AT NORTH WALL IN THE 2nd ROOM FROM NORTH LOCATED AT APT 7E, 7th STORY, 2nd APARTMENT FROM EAST AT SOUTH | Open |
| Sep 23, 2026 | HPD A | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN TEN SQUARE FEET AT CEILING AND EAST WALL INSIDE CLOSET AT NORTH WALL IN THE 2nd ROOM FROM NORTH LOCATED AT APT 7E, 7th STORY, 2nd APARTMENT FROM EAST AT SOUTH | Open |
| Sep 22, 2026 | HPD B | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT SOUTH WALL IN THE 3rd ROOM FROM NORTH LOCATED AT APT 7E, 7th STORY, 2nd APARTMENT FROM EAST AT SOUTH | Open |
| Sep 22, 2026 | HPD B | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE COUNTER BALANCE AT LOWER WINDOW SASH AT 3RD WINDOW FROM WEST AT SOUTH WALL. AT PUBLIC HALL, 7th STORY | Open |
| Sep 16, 2026 | DOB Safety | Facades: FISP Unsafe report filed | Closed |
| Aug 20, 2026 | HPD C | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 5A, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 14, 2026, 8:34 PM ET. BBL 1020710036.