Brooklyn · Block 1095 · Lot 50 · 11215

161 Prospect Park West

4 floors · 8 apartments · 9,576 sq ft · built 1899 · class C1 · owner of record: 161 Ppw Owner Llc

36open violations
$10,000ECB/OATH penalties owed
12HPD class C (immediately hazardous)
64dto Gas piping inspection (2026 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 6 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 64 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 64 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 64 days
Annual
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-01-10 (Accepted). Agency page

Dec 31, 2026
in 64 days
1 of 1 without an accepted 2026 report yet
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 80 days
Annual
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 308 days
Registered through 2027-09-01

Open violations

ECB / OATH (6) · $10,000 owed
IssuedViolationHearingBalance
Jan 16, 2026Construction CLASS - 2
FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS.NO CERTIFICATE OF CORRECTION ON FILE FOR VIO#39079593M AS OF 1/16/26., FILE A CERTIFICATE OF
#39174252J
Mar 25, 2026
IN VIOLATION
$0
Jul 29, 2025Construction CLASS - 2
AT TIME OF INSPECTION OBSERVED: SIDEWALK SHED INSTALLED AT EXPOSURE# 1 -2 WITH OPEN GAP 12" APPROX. NOT SEALED OR TIGHT TO FACADE CONTRARY TO BC 3307.6.4.5 CREATING A POTENTIAL SAFETY CONDITION, MATERIALS, TOOL
#39542962K
Oct 8, 2025
DEFAULT
$10,000
May 1, 2025Construction CLASS - 2
FAILED TO CERTIFY FOR CORRECTION FOR SUMMONS #39079593M, FILE A CERTIFICATE OF CORRECTION
#39146689Y
Aug 25, 2025
IN VIOLATION
$0
Jan 9, 2025Boilers CLASS - 2
WEILMCLAIN STEAM BOILER>SURGING+PRIMING NEEDS 'BLOW DOWN'+TOP FLOOR QUICK VENT DEFECTIVE+IN APT-3L DEFECTIVE RADIATOR AIR VALVE>MIDDLE ROOM;CORRECT VIOLATION+SUBMIT CERTIFICATE OF CORRECTION
#39135069J
Dec 29, 2025
IN VIOLATION
$0
Jun 12, 2024Construction CLASS - 2
AT TIME OF INSPECTION OBSERVED DISPLACED ORNAMENTAL BRICK AND MORTAR JOINTS AT 1ST STY LEVEL , LEFT SIDE OF EXP.2, MAINTAIN EXTERIOR BUILDING WALL
#39116715L
Aug 21, 2024
STIPULATION/IN-VIO
$0
Feb 13, 2023Construction CLASS - 1
AT TIME OF INSPECTION OBSERVED FACADE IN STATE OF DISREPAIR. AT EXPOSURE 4 AT 3 FLOOR WINDOW STONE ORNAMENTS MISSING PIECES AND FALING INTO TO PEDESTRIAN SIDEWALK. AT EXPOSURE 1,2 AND 4 FACADE HAVE CRACKS AT MU
#39079593M
Apr 19, 2023
IN VIOLATION
$0
DOB (3)
IssuedViolationStatus
Nov 14, 2025LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
#08911
DOB VIOLATION - ACTIVE
Nov 29, 2002LANDMARK

#03-0447
DOB VIOLATION - ACTIVE
Aug 16, 1993LOCAL LAW 62/91 - BOILERS

#33907
DOB VIOLATION - ACTIVE
DOB NOW Safety (2)
IssuedViolationStatus
Mar 17, 2026AEUHAZ FTC-AEU-HAZ
Active
Nov 14, 2025Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
Active
HPD (25) · C 12 · B 9 · A 4
IssuedClassViolationCorrect by
Feb 3, 2026B§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GREATER THAN 30 SQUARE FEET AT CEILING, BASEMENT AT PUBLIC HALL ORIGINAL VIOLATION 18263330 ISSUED 30-SEP-25 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE 27-2017.3a(3)(a) or (b).Mar 10, 2026
May 27, 2025B§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING NORTH AT BOILER ROOMJul 1, 2025
May 27, 2025CApt 3L · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 3L, 3rd STORY, 1st APARTMENT FROM WEST AT NORTHMay 24, 2025
May 27, 2025CApt 3L · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCH IN THE ENTRANCE LOCATED AT APT 3L, 3rd STORY, 1st APARTMENT FROM WEST AT NORTHJun 10, 2025
May 27, 2025CApt 3L · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE KITCHEN LOCATED AT APT 3L, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTMay 27, 2025
May 22, 2025B§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE RETARDANT MATERIAL AT CEILING AT CELLARJun 26, 2025
Feb 19, 2025CApt 3L · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE ...HINGE IN THE ENTRANCE LOCATED AT APT 3L, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTMar 5, 2025
Jan 13, 2025CApt 3L · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 3L, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTJan 10, 2025
Jan 13, 2025CApt 3L · § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 3L, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTJan 10, 2025
Jan 10, 2025CApt 3L · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE DOOR HINGES IN THE ENTRANCE LOCATED AT APT 3L, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTJan 24, 2025
Jan 10, 2025CApt 3L · § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE 3rd ROOM FROM EAST AT SOUTH LOCATED AT APT 3L, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTJan 10, 2025
Jan 10, 2025CApt 3L · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE 3rd ROOM FROM EAST AT SOUTH LOCATED AT APT 3L, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTJan 10, 2025
Oct 28, 2024BApt 3L · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LIGHT FIXTURE FLICKERING AT EAST WALL IN THE BATHROOM LOCATED AT APT 3L, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTDec 2, 2024
Oct 28, 2024CApt 2L · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st WINDOW FRAME FROM WEST AT NORTH WALL IN THE 3rd ROOM FROM EAST AT NORTH LOCATED ATNov 21, 2024
Oct 28, 2024CApt 2L · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st WINDOW FRAME FROM WEST AT NORTH WALL IN THE BATHROOM LOCATED AT APT 2L, 2nd STORY,Nov 21, 2024
Jan 19, 2024BApt 2R · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX. 1SQ.FT INSIDE BASE CABINET IN THE KITCHEN LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH ORIGINAL VIOLATION 16238531 ISSUED 20-SEP-23 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-Feb 23, 2024
Jan 3, 2024BApt 2R · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... INSIDE LOWER BASE CABINET BENEATH SINK (APPROX. 2 SQ. FT.) IN THE KITCHEN LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH ORIGINAL VIOLATION 16199893 ISSUED 01-SEP-23 HAS BEEN UPGRADED TO CLASS B PER Feb 7, 2024
Sep 22, 2023AApt 2R · § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION SUSPENDED ACOUSTIC TILES AT CEILING IN THE 3rd ROOM FROM NORTH AT WEST LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTHDec 26, 2023
Sep 22, 2023AApt 2R · § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION SUSPENDED ACOUSTIC PANELS AT CEILING IN THE PRIVATE HALLWAY LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTHDec 26, 2023
Sep 22, 2023AApt 2R · § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION SUSPENDED ACOUSTIC PANEL AT CEILING IN THE 2nd ROOM FROM NORTH AT WEST LOCATED AT APT 2R, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTHDec 26, 2023
Jun 16, 2023BApt 3L · 28 RCNY § 25-171; & 67 (7)(B) MDL; NYC FIRE CODE § 703.1.3; NYC FIRE CODE § 703.2: ADJUST DOOR TO PREVENT GAPS BETWEEN THE TOP AND SIDE EDGES OF DOOR AND DOOR JAMB EXCEEDING THE MAXIMUM ALLOWABLE CLEARANCE OF 1/8 OF AN INCH AND MAXIMUM ALLOWABLE CLEARANCE OF 3/4 OF AN INCH BETWEEN THE DOOR BOTTOM ANJul 21, 2023
Jun 15, 2023BApt 3L · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LOWER SASH COUNTER BALANCES AT SOUTH WINDOWS IN THE 3rd ROOM FROM EAST AT SOUTH LOCATED AT APT 3L, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTJul 20, 2023
Jun 15, 2023BApt 3L · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LOWER SASH COUNTER BALANCE AT SOUTH WINDOW IN THE KITCHEN LOCATED AT APT 3L, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTJul 20, 2023
Jun 15, 2023AApt 3L · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE INTERCOM SYSTEM FROM BUILDING ENTRANCE TO RETURN BUZZER AT EAST WALL IN THE KITCHEN LOCATED AT APT 3L, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTSep 18, 2023
Apr 6, 2023C§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE MISSING FIRE STOPPING MATERIAL AT CEILING AT BASEMENTApr 12, 2023

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 28, 2026, 9:31 AM ET. BBL 3010950050.