6 floors · 21 apartments · 39,750 sq ft · built 1911 · class D0 · owner of record: 165 Housing Corp
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 2026-09-01 |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 66 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 66 days | Annual |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-01-15 (Accepted). Agency page | Dec 31, 2026 in 66 days | 1 of 1 without an accepted 2026 report yet |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 82 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 39,750 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 187 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 187 days | Annual filing |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 2 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1162 days | Next cycle year 2029 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Aug 22, 2025 | Construction CLASS - 1 OBSERVED ON SIXTH FLOOR MAIN ROOF STRUCTURE IS COMPROMISED AND INADEQUATE SHORING USED TO SUPPORT ROOF. NO DETAILS FOR STRUCTURAL STABILITY ATTESTED FOR AND NO PERMIT FOR SHORING., OBTAIN PERMIT; OBTAIN PERMIT #39158127K | Oct 30, 2025 IN VIOLATION | $2,500 |
| Aug 22, 2025 | Construction CLASS - 1 OBSERVED ON SIXTH FLOOR MAIN ROOF STRUCTURE IS COMPROMISED AND INADEQUATE SHORING USED TO SUPPORT ROOF. ENTIRE SIXTH FLOOR IN COLLAPSE ZONE., REPAIR AND/REPLACE; MAKE REPAIRS #39158128M | Oct 30, 2025 IN VIOLATION | $2,500 |
| Issued | Violation | Status |
|---|---|---|
| Aug 26, 2025 | CONSTRUCTION FAILURE TO MAINTAIN. SUBMIT PLANS/DETAILS TO CEU BY 12/01/2025 REMEDY: OWNER TO RETAIN A NYS PE TO PREPARE PERMANENT RENOVATION PLANS AND DETAILS, FILE RENOVATION JOB & OBTAIN WORK PERMIT. SUBMIT PLANS/ DETAILS TO CEU #CEU10201NH | DOB VIOLATION - ACTIVE |
| Aug 22, 2025 | CONSTRUCTION EMERGENCY WORK ORDER.@TIME OF INSPECTION,OBSRVD MAIN ROOF DRAPD MESH UNDR CNCRTE SLAB IN A STATE OF DISREPAIR W/CRCKS,SAGGNG,&CORRODED REINFORCMNT.OBSRVD UNENGINEERD&INADEQUATE SHORNG PRTLLY.OWNR TO ENGAGE NYSPE&ENDRSD CNTRCTR TO EVAL THE ENT ROOF STRCTRE&IMMED INSTLL TEMP SHORNG UNDR EMRGNCY WRK #FEU10201AK | DOB VIOLATION - ACTIVE |
| Aug 22, 2025 | CONSTRUCTION FAILURE TO MAINTAIN.@TIME OF INSPECTION,OBSRVD MAIN ROOF DRAPED MESH UNDR CNCRTE SLAB IN A STATE OF DISREPAIR W/CRACKS,SAGGNG,&CORRODED REINFORCMNT.OBSRVD UNENGINEERD&INADEQUATE SHORNG PRTLLY.OWNR TO ENGAGE NYSPE&ENDRSD CNTRCTR TO EVAL THE ENT ROOF STRCTRE&REPAIR UNDR PRMT FILE FOR PRMTS BY 9/22/25. #FEU10202AK | DOB VIOLATION - ACTIVE |
| Sep 24, 2020 | ELEVATOR #9027/689835 | DOB VIOLATION - ACTIVE |
| Sep 6, 2019 | (OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2017 CAT 1 INSP/TST TST #00725 | DOB VIOLATION - ACTIVE |
| Jan 3, 2017 | (OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2015 CAT 1 INSP/TST #00860 | DOB VIOLATION - ACTIVE |
| Nov 14, 2016 | (OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2014 CAT 1 INSP/TST #00965 | DOB VIOLATION - ACTIVE |
| Nov 14, 2016 | (OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2014 CAT 1 INSP/TST #00964 | DOB VIOLATION - ACTIVE |
| May 15, 2014 | LOW PRESSURE BOILER VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT #02633 | DOB VIOLATION - ACTIVE |
| Aug 15, 2012 | ELEVATOR #ACC100953 | DOB VIOLATION - ACTIVE |
| Mar 21, 2008 | LOCAL LAW 10/81 - ELEVATOR #00498 | DOB VIOLATION - ACTIVE |
| Nov 30, 2007 | LOCAL LAW 11/98 - FACADE #NRF42413 | DOB VIOLATION - ACTIVE |
| Nov 19, 2004 | LOCAL LAW 10/81 - ELEVATOR #00386 | DOB VIOLATION - ACTIVE |
| May 4, 1998 | LOCAL LAW 62/91 - BOILERS #06200 | DOB VIOLATION - ACTIVE |
| Sep 16, 1997 | LOCAL LAW 62/91 - BOILERS #170135 | DOB VIOLATION - ACTIVE |
| Feb 10, 1997 | LOCAL LAW 62/91 - BOILERS #02608 | DOB VIOLATION - ACTIVE |
| May 31, 1994 | LOCAL LAW 10/81 - ELEVATOR #00383 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Mar 17, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Mar 17, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2020 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2021 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2020 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2018 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2021 Cat1 Test Affirmation of Correction | Active |
| Oct 2, 2023 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2022 Periodic Inspection Affirmation of Correction | Active |
| Oct 2, 2023 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2022 Periodic Inspection Affirmation of Correction | Active |
| Sep 6, 2019 | Elevators ACC1 | Active |
| Jan 3, 2017 | Elevators ACC1 | Active |
| Nov 14, 2016 | Elevators ACC1 | Active |
| Nov 14, 2016 | Elevators ACC1 | Active |
| May 15, 2014 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT | Active |
| Aug 15, 2012 | Elevators E | Active |
| Aug 15, 2012 | Elevators E | Active |
| Mar 21, 2008 | Elevators LL1081 | Active |
| Nov 30, 2007 | Facades LL1198 CYCLE 6 NO REPORT FILED | Active |
| Nov 19, 2004 | Elevators LL1081 | Active |
| May 4, 1998 | Boiler LL6291 | Active |
| Sep 16, 1997 | Boiler LL6291 | Active |
| Feb 10, 1997 | Boiler LL6291 | Active |
| May 31, 1994 | Elevators LL1081 | Active |
| May 31, 1994 | Elevators LL1081 | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Oct 14, 2021 | B | Apt 1A · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT SOUTH WALL 2 SQ FT IN THE BATHROOM LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST ORIGINAL VIOLATION 14341652 ISSUED 15-JUN-21 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a | Nov 18, 2021 |
| Oct 14, 2021 | B | Apt 1A · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... 2 SQ FT AT EAST WALL IN THE 2nd ROOM FROM NORTH LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST ORIGINAL VIOLATION 14341653 ISSUED 15-JUN-21 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-20 | Nov 18, 2021 |
| Jun 17, 2021 | B | Apt 1A · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT NORTH WALL LOWER LEVER DUBLEX IN THE PRIVATE HALLWAY LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Jul 22, 2021 |
| Jun 17, 2021 | B | Apt 1A · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE NORTH WALL AT LOWER LEVEL DUBLEX IN THE PRIVATE HALLWAY LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Jul 22, 2021 |
| Jun 17, 2021 | B | Apt 1A · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE NORTH WALL AT LOWER LEVEL DUBLEX IN THE PRIVATE HALLWAY LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Jul 22, 2021 |
| Jun 17, 2021 | B | Apt 1A · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT NORTH WALL AT LOWER LEVEL IN THE PRIVATE HALLWAY LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Jul 22, 2021 |
| Jun 16, 2021 | C | Apt 1A · § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE ... IN THE ENTRANCE LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Jul 12, 2021 |
| Jun 16, 2021 | A | Apt 1A · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE EAST WALL IN THE 2nd ROOM FROM NORTH LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Sep 19, 2021 |
| Jun 16, 2021 | A | Apt 1A · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE CAULKING AROUND WASH BASIN IN THE BATHROOM LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Sep 19, 2021 |