2 floors · 13 apartments · 15,068 sq ft · built 1910 · class C1 · owner of record: 1603 Lincoln Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 8 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 62 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 62 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 62 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 78 days | Annual |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 306 days | Registered through 2027-09-01 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Jul 28, 2020 | Construction CLASS - 1 UNLAWFULLY CONTINUED WORK WHILE ON NOTICE OF A STOP WORK ORDER. REF TO DOB RECORDS PSWO ISSUED ON 01/02/2020 FRO NOT ALLOWED WORK ON BACK YARD INCLUDING (EXPO#3) UNTIL TO PROVED APPROVED PLAN FOR ILLEGALLY INST #39026079K | Jul 30, 2021 IN VIOLATION | $5,000 |
| Jul 28, 2020 | Construction CLASS - 1 NEW BUILDING OR OPEN LOT OCCUPIED WITHOUT A VALID CERTIFICATE OF OCCUPANCY. OBSERVED AT TIME OF INSPECTION APT # 2B (2 BEDROOMS) ILLEGALLY BEING OCCUPIED BY ONE MAN WITH FULL FURNITURE WITH NO C/O IN DOB RECORD #39026084P | Jul 30, 2021 IN VIOLATION | $2,500 |
| Mar 13, 2020 | Construction CLASS - 1 FAILURE TO INSTITUTE/MAINTAIN SAFETY EQUIPMENT MEASURES OR TEMPORARY CONSTRUCTION.(NO HANDRAILS) NOTED:AT TIME OF INSPECTION OF AN ACTIVE JOBSITE. OBSERVED WORK AT CELLAR LEVEL AND NO HANDRAIL WAS INSTALL ON ST #35470846H | Jul 15, 2020 IN VIOLATION | $2,500 |
| Mar 13, 2020 | Construction CLASS - 2 JOBSITE FENCE NOT CONSTRUCTED OR NOT MAINTAIN PURSUANT TO SUBSECTION. NOTED:AT TIME OF INSPECTION OF AN ACTIVE JOBSITE. OBSERVED JOBSITE FENCE NOT MAINTAIN OUT OF PLUMB AND LEANING OUTWARDS,PART OF THE FENCE IS #35470845X | Jul 15, 2020 IN VIOLATION | $500 |
| Mar 13, 2020 | Construction CLASS - 1 FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY. NOTED:AT TIME OF INSPCTION OF AN ACTIVE JOBSITE. OBSERVED THE EXIT PASSAGEWAY FROM THE BUILDING AND FROM THE ADJOINING PROPERTY REAR YARD IS OBSTRUCTED BY CABLE #35470844Y | Jul 15, 2020 IN VIOLATION | $1,250 |
| Mar 13, 2020 | Construction CLASS - 1 FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING PER SECTION REQUIREMENTS. NOTED:AT TIME OF INSPECTION OF AN ACTIVE JOBSITE. AT EXP#1 YARD OBSERVEDINADEQUATE HOUSEKEEPING WHICH MADE UP OF CONSTRUCTION DEBRIS AND COMBU #35470842K | Jul 15, 2020 IN VIOLATION | $625 |
| Dec 26, 2019 | Construction CLASS - 1 JOBSITE FENCE AT THE TIME OF INSPECTION OF 4 STORY BUILDING AN ACTIEV JOBSIET I OBSERVED 2 WORKERS JOBSITE I WAS TOLD GOING TO GET MATERIALS I OBSERVED EXP #1 JOBSITE GATE WAS NOT AS SHOULS BE PER CODE GATE OPE #35461998M | Apr 29, 2020 IN VIOLATION | $500 |
None open.
| Issued | Violation | Status |
|---|---|---|
| Oct 31, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle C (premises is in Community District 8) | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Jun 30, 2026 | A | §27-2104(B) HMC POST A PROPER NOTICE REGARDING RENT STABILIZATION LAW, IN A FORM APPROVED BY THE COMMISSIONER, IN A CONSPICUOUS LOCATION WITHIN THE COMMON AREA AT THE BUILDINGS ENTRANCE. FOR MORE INFORMATION ABOUT SIGNAGE REQUIREMENTS, PLEASE VISIT: HTTPS://WWW.NYC.GOV/SITE/HPD/SERVICES-AND-INFORMA | Oct 3, 2026 |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 30, 2026, 6:01 PM ET. BBL 3013870064.