4 floors · 411,500 sq ft · built 1931 · class W1 · owner of record: Nyc Department Of Education
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 43 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 411,500 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 164 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 164 days | Annual filing |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 14 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 408 days | Next cycle year 2027 |
| Energy audit and retro-commissioning (2034) Likely applies Local Law 87 · Calendar year 2034 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 6734). Agency page | Dec 31, 2034 in 2965 days | Next due 2034 |
| Annual boiler inspection (4 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-01-27 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Feb 20, 2025 | Construction CLASS - 2 REISSUE #35679025H; FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.: AT ROOF LEVEL FANS ROOM BRICK FACADE. MISSING BRICK/MORTAR FACING SOUTH SIDE IN VARIOUS LOCATIONS. REMEDY: REPAIR AND/OR REPLACE. #35684780H | Apr 28, 2025 POP/IN-VIO | $0 |
| Jul 17, 2024 | Elevators CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. IN CAR ALARM INOPERATIVE, REPAIR. #39119318L | Jul 27, 2024 POP/IN-VIO | $0 |
| Mar 13, 2024 | Construction CLASS - 2 RE-ISSUE #35672565R. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: AT ROOF LEVEL, THE EXTERIOR BRICKS ON THE SOUTH SIDE IS MISSING MORTAR. REMEDY: REPAIR AND/OR REPLACE. #35679025H | May 6, 2024 POP/IN-VIO | $0 |
| Mar 13, 2024 | Construction CLASS - 2 RE-ISSUE #35672564P. FAILURE TO MAINTAIN BUILDNG IN CODE-COMPLIANT MANNER. NOTED: OBSERVED IN THE CELLAR IN THE BOILER ROOM, THE FOUNDATION IS POROUS, WHICH IS ALLOWING WATER TO COME IN TO THE BASE. REMEDY: REP #35679026J | May 6, 2024 POP/IN-VIO | $0 |
| Mar 30, 2023 | Construction CLASS - 2 REISSUE #35663252L FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NOTED:AT ROOF TOP FAN ROOM BRICK FACADE MISSING MORTAR AT MULTIPLE SIDES OF ENCLOSURE.REMEDY:MAKE NECESSARY REPAIRS. #35672565R | Jun 21, 2023 POP/IN-VIO | $0 |
| Mar 30, 2023 | Construction CLASS - 2 REISSUED #35663253N FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NOTED:AT BOILER RM RETAINING WALL/FOUNDATION WALL BECOME POROUS ALLOWING RAINWATER INTO BOILER ROOM.REMEDY:MAINTAIN EXTERIOR WALL. #35672564P | Jun 21, 2023 POP/IN-VIO | $0 |
| Jun 23, 2022 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NOTED:OBSERVED DURING INSPECTION OF ROOF LEVEL FAN ROOM ENCLOSURE,MISSING MORTAR ON EXTERIOR FACADE AT MULTIPLE SIDES OF ENCLOSURE.REM:REPAIR AND/OR REPLACE #35663252L | Nov 16, 2022 POP/IN-VIO | $0 |
None open.
| Issued | Violation | Status |
|---|---|---|
| Oct 10, 2025 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction | Active |
| Oct 11, 2024 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2023 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2020 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2019 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2018 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2021 Cat1 Test Affirmation of Correction | Active |
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 18, 2026, 9:05 AM ET. BBL 3067340109.