Brooklyn · Block 3280 · Lot 38 · 11237

160 Wyckoff Avenue

3 floors · 4 apartments · 4,500 sq ft · built 1931 · class S4 · owner of record: Bologna, Mario

26open violations
$0ECB/OATH penalties owed
3HPD class C (immediately hazardous)
50dto Gas piping inspection (2026 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 4 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 50 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 50 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 50 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 66 days
Annual
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 294 days
Registered through 2027-09-01
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-08-31 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (0)

None open.

DOB (2)
IssuedViolationStatus
Jun 30, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION
#07164
DOB VIOLATION - ACTIVE
Jun 30, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION
#27163
DOB VIOLATION - ACTIVE
DOB NOW Safety (2)
IssuedViolationStatus
Jun 30, 2023Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION
Active
Jun 30, 2023Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION
Active
HPD (22) · C 3 · B 12 · A 7
IssuedClassViolationCorrect by
Jun 19, 2008AD26-10.01 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDING CEILING CELLAR THROUGHOUT.Sep 22, 2008
Jun 19, 2008AD26-11.01, 11.03, 11.05 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE CELLAR THROUGHOUT.Sep 22, 2008
Jun 19, 2008BD26-10.01, 10.05 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES 2X4 AND PALSTIC ROOF REAR YARD HOUSE TO GARAGE IN WAY OF DROPLADDER.Jul 24, 2008
Jun 19, 2008BD26-19.05 ADM CODE PROVIDE ADEQUATE LIGHT OF NOT LESS THAN 60 WATTS INCANDESCENT OR EQUIVALENT ILLUMINATION PUBLIC HALL ALL STYS.Jul 24, 2008
Jun 19, 2008ASECTION 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR FRAME MISSING.Sep 22, 2008
Jun 19, 2008BApt 3R · D26-10.01 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE WINDOW SASH & FRAME THRU OUT 3 STY APT 3R. , SECTION '' ''Jul 24, 2008
Jun 19, 2008BApt 3R · D26-13.03 ADM CODE ABATE THE NUISANCE CONSISTING OF VERMIN MICE & ROACHES 3 STY APT 3R. , SECTION '' ''Jul 24, 2008
Jun 19, 2008AApt 3R · D26-10.01 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE CEILING LIGHT FIXTURE 3 STY APT 3R CENTER ROOM. , SECTION '' ''Sep 22, 2008
Jun 19, 2008AApt 3R · D26-12.01 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WALLS & CEILINGS THRU OUT 3 STY APT 3R. , SECTION '' ''Sep 22, 2008
Jun 19, 2008AApt 3R · D26-16.01 ADM CODE RESET, SO AS TO SECURE A PROPER AND TIGHT CONNECTION, THE WATER CLOSET BOWL 3 STY APT 3R BATHROOM. , SECTION '' ''Sep 22, 2008
Jun 19, 2008BApt 3R · D26-10.01 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF EAST ENTRANCE DOOR NAILED SHUT 3 STY APT 3R. , SECTION '' ''Jul 24, 2008
Jul 28, 2006AApt 1 · SECTION 27-2005 ADM CODE REFIT ENTRANCE DOOR TO 1ST STY REAR APT 1 LOCATED AT APT 1Nov 24, 2006
Dec 8, 1998BSECTION 27-2040 ADM CODE PROVIDE ADEQUATE LIGHTING AT OR NEAR THE OUTSIDE OF THE FRONT ENTRANCEWAY OF THE BUILDING AND KEEP SAME BURNING FROM SUNSET EVERY DAY TO SUNRISE ON THE DAY FOLLOWING 100 WATTS INCAND FIXTURE PRESENT LIGHT NOT ONJan 25, 1999
Sep 8, 1998BApt 1 · SECTION 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS ENTRANCE TO 1ST STY REAR APT 1 LOCATED AT APT 1Oct 26, 1998
Sep 8, 1998BApt 1 · SECTION 27-2005 ADM CODE REPLACE WITH NEW THE MISSING LIGHT SWITCH FOYER ENTRANCE TO 1ST STY REAR APT 1 LOCATED AT APT 1Oct 26, 1998
Sep 8, 1998CApt 1 · SECTION 27-2013 ADM CODE REMOVE OR COVER IN A MANNER APPROVED BY THE DEPARTMENT THE PEELING LEAD PAINT KITCHEN CEILING 1ST STY REAR APT 1 MS PENA 417 0445 ER1 10438 LOCATED AT APT 1Sep 28, 1998
Sep 8, 1998CSECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF CASCADING WATER LEAK KITCHEN CEILING 1ST STY REAR APT ER1Sep 28, 1998
Sep 8, 1998BApt 1 · SECTION 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION WASTELINE WASH BASIN BATHROOM 1ST STY REAR APT 1 LOCATED AT APT 1Oct 26, 1998
Sep 8, 1998BApt 1 · SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING AT 1ST STY REAR APT 1 LOCATED AT APT 1Oct 26, 1998
Sep 8, 1998BApt 1 · SECTION 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES WASH BASIN BATHROOM 1ST STY REAR APT 1 ER1 LOCATED AT APT 1Oct 26, 1998
Sep 8, 1998CSECTION 27-2018 ADM CODE ABATE THE NUISANCE CONSISTING OF RODENTS RATS THROUGHOUT 1ST STY REAR APT1Sep 28, 1998
Sep 8, 1998BApt 1 · SECTION 27-2005 ADM CODE REPLACE WITH NEW THE MISSING DOOR KNOB ENTRANCE TO 1ST STY REAR APT 1 LOCATED AT APT 1Oct 26, 1998

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 11, 2026, 3:14 PM ET. BBL 3032800038.