| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 63 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 46,500 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 184 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 184 days | Annual filing |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 794 days | Next cycle year 2028 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Apr 6, 2025 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER. BUILDING MEZZANINE FLOOR IN SEVERE STATE OF DISREPAIR AND DETERIORATED WITH AN OPEN SECTION OF APPROXIMATELY 3'X4' FEET AREA. ONE OF THE WORKERS FROM FOU #39144021P | Sep 3, 2026 IN VIOLATION | $12,500 |
| Issued | Violation | Status |
|---|---|---|
| Jul 29, 2026 | CONSTRUCTION FAILURE TO MAINTAIN BUILDING WALLS, VERTICAL AND HORIZONTAL CRACKS OBSERVED AT EXPOSURE 3 WALL. CONCREATE FLOOR AT EXPOSURE 3 EXTERIOR HAS SEVERE DAMAGE DUE TO EROSION. #26-01881 | DOB VIOLATION - ACTIVE |
| Feb 5, 2026 | CONSTRUCTION FAILURE TO COMPLY WITH COMMISSIONER'S ORDER #350482(012126FEU30102BP) DATED 1/22/26 REQUIRING OWNER TO IMMED ERECT TGHTBRD FNCE TO SECURE THE CLLPSE ZONE TO THE 2ND COL BAY&PREVNT UNAUTHORIZD ACCESS TO THE REAR 50FT OF THE BLDG&REAR YRD AS REQ'D,&FILE FOR PRMT W/IN 2DAYS FROM STRT OF WRK.AS OF 2/5/2 #FEU30101BP | DOB VIOLATION - ACTIVE |
| Feb 3, 2026 | CONSTRUCTION FAILURE TO COMPLY W/COMMISSIONER'S ORDER #350483(012126FEU30103BP) DATED 11/22/26 REQUIRING OWNER TO IMMEDIATELY SUBMIT MEANS&METHODS FOR REVIEWING/APPROVAL&PRTLLY DEMO&TEMP BRACE/SHORE STBLIZE THE BLDG UNDER FULLTIME PE SPRVSN.AS OF 2/5/26,FEU HAS NOT RECEIVD PROPOSD MEANS& METHDS FOR OUR REVIEW&AP #FEU30102BP | DOB VIOLATION - ACTIVE |
| Jan 21, 2026 | CONSTRUCTION EMERGENCY WORK ORDER.EXP2/3 CORNER COLUMN UNSUPPORTD DUE TO PRTLLY CLLPSE/COMPROMSD&AT RISK OF CLLPSE.EXTERIOR EXP2&EXP3 CMU WALLS CRCKD SETTNG&AT RISK OF COLLAPSE.IMMED ERECT TGHTBRD FENCE TO SECURE THE CLPSE ZONE TO THE 2ND COLUMN BAY&PREVENT UNAUTHORIZD ACCES TO THE CLLPSE ZONE #FEU30102BP | DOB VIOLATION - ACTIVE |
| Jan 21, 2026 | CONSTRUCTION EMERGENCY WORK ORDER.EXP2/3 CORNER COLUMN UNSUPPORTD DUE TO PRTLLY CLLPSD/COMPROMISD TIMBER PILES&CONCRETE GRADE BEAM/PILE CAP FOUNDATN REAR 25FT DEEP BAY STRUC COMPROMISD&AT RISK OF COLLAPSE.OWNR TO IMMED RTAIN NYSPE&DEMO ENDRSD GC TO 1.SUBMT MEANS & METHDS TO FEU,2.PRTLLY DEMO THE REAR BLDG.TEMP B #FEU30103BP | DOB VIOLATION - ACTIVE |
| Apr 29, 2021 | FAILURE TO POST ENERGY GRADE/SCORE FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3 #2003353 | DOB VIOLATION - ACTIVE |
| Oct 1, 2015 | LOW PRESSURE BOILER VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2014 INSPECTION REPORT #07105 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Dec 3, 2025 | Benchmarking - LL84 FTF-EN-BENCH FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 | Active |
| Sep 26, 2025 | Benchmarking - LL84 FTF-EN-BENCH FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 | Active |
| Apr 29, 2021 | Energy Grade - LL33 FTP-EN-EGRDEA | Active |
| Oct 1, 2015 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2014 INSPECTION REPORT | Active |
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Jul 29, 2026 | DOB | CONSTRUCTION: FAILURE TO MAINTAIN BUILDING WALLS, VERTICAL AND HORIZONTAL CRACKS OBSERVED AT EXPOSURE 3 WALL. CONCREATE FLOOR AT EXPOSURE 3 EXTERIOR HAS SEVERE DAMAGE DUE TO EROSION. | Open |