Manhattan · Block 593 · Lot 47 · 10014

16 Gay Street

3 floors · 4 apartments · 1,380 sq ft · built 1828 · class C3 · owner of record: Gay Street Revival Initiative 2 Llc

58open violations
$51,250ECB/OATH penalties owed
12HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueRegistration expired 2021-09-01
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 44 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 44 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 60 days
Annual
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 2 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1140 days
Next cycle year 2029

Open violations

ECB / OATH (7) · $51,250 owed
IssuedViolationHearingBalance
Nov 7, 2025Unknown CLASS - 2
FAILURE TO OBTAIN TEMPORARY WORK PERMIT. GREEN PANELING FENCE CONSTRUCTED IN FRONT OF BUILDING WITH EXPIRED WORK PERMIT., OBTAIN TEMPORARY CONSTRUCTION PERMIT
#39166299R
Jan 15, 2026
DEFAULT
$6,250
Nov 7, 2025Construction CLASS - 2
FAILURE TO COMPLY WITH COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPT. OF BUILDINGS FOR VIOLATION #39079298J, FILE A CERTIFICATE OF CORRECTION
#39166279J
Jan 15, 2026
DEFAULT
$6,250
Nov 7, 2025Construction CLASS - 1
FAILURE TO COMPLY WITH COMMISSIONER'S ORDER TO OBTAIN WORK PERMITS FOR DOB VIOLATION 080222CFEU10202IK, COMPLY WITH COMMISSIONER'S ORDER
#39166280R
Jan 15, 2026
DEFAULT
$25,000
Apr 25, 2025Construction CLASS - 1
FAILURE TO COMPLY WITH DOB VIOLATION #121823FEU10202A ISSUED ON 12/18/2023 TO OBTAIN PERMIT TO START REPAIRS., COMPLY WITH COMMISSIONER'S ORDER; COMPLY WITH COMMISSIONER ORDER AND FILE FOR PERMITS
#39146027P
Jul 3, 2025
DEFAULT
$12,500
Sep 11, 2023Construction CLASS - 2
FAILURE TO COMPLY WITH COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH DOB. ECB VIO # 39508897Y ISSUED ON 11/09/2022 UNDER COMPLAINT # 1622248 FOR WORK WITHOUT A PERMIT. NO COMPLIANCE RECORDED FOR
#39094524Y
Dec 14, 2023
IN VIOLATION
$1,250
Feb 8, 2023Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. PORTION OF FOUNDATION WALL AT EXP #2 OF PROPERTY REMOVED CREATING UNSAFE CONDITION. BLDG IS STRUCTURALLY COMPROMISED WITH SHORING IN PLACE THROUGHOUT CELLA
#39079298J
Apr 20, 2023
IN VIOLATION
$0
Nov 9, 2022Construction CLASS - 1
WORK WITHOUT PERMIT, STOP ALL FOUNDATION WORK, OBTAIN PERMITOBTAIN PERMIT
#39508897Y
Jan 26, 2023
ADMIT/IN-VIO
$0
DOB (10)
IssuedViolationStatus
Dec 18, 2023CONSTRUCTION
REFER TO COMMISSIONER'S ORDER CONTROL #340772 (080222FEU10202IK)FOR DESCRIPTION OF VIOLATING CONDITIONS.OWNR TO RTAIN NYS PE TO EVAL ENT BLDG&DEVELOP COMPREHENSIVE RPAIR PLANS.RTAIN DOB REG CNTRCTR TO RPAIR THE BLDG UNDR PRMT
#FEU10202AK
DOB VIOLATION - ACTIVE
Feb 6, 2023CONSTRUCTION
FTM-LANDMARK BLDG.FACADE @EXP1 BOWING OUT W/VARIOUS CRCKS APPARENT CONCRT UNDRPINNING OF ALL EXTERIOR WALLS.DTERIORATED WALLS IN AREA WAY SLOPING WOOD FRMD FLRS W/UNENGNRD JOISTS RPRS.COMPLY WITH COMMISSIONER'S ORDER #080222FEU10202IK
#FEU10202IK
DOB VIOLATION - ACTIVE
Nov 7, 2022CONSTRUCTION
PREMISE NON-COMPLIANT DUE TO STRUCTURALLY COMPROMISED DUE TO INADEQUATE SHORING AT TIME OF INSPECTION
#22-04142
DOB VIOLATION - ACTIVE
Nov 7, 2022CONSTRUCTION
EMERG WORK-WHILE 14 GAY WAS UNDRGING STRUCT RPR,ENTIRE LGNTH EXP2 SHARED FNDTN WALL REMOVD &PART REPLCD W/NEW CMU WALL.INADQ SHRNG FLOOR @ INTERIOR.BLDG UNSTABLE & AT RISK OF COLLAPSE OWNR IMMED RETAIN CONTRCT ERRECT TIGHTBRD FENCE@FRNT& REAR PROPRTY ENCL COLLAP ZONE.@ FRNT FENC TO MID ST.LEAV 1 LN
#FEU10202IK
DOB VIOLATION - ACTIVE
Nov 7, 2022CONSTRUCTION
EMGCY WRK-WHILE RPR WRK @ADJ BLDG EXP2 ONGOING,ENTIRE LENGTH OF FDN WALL UNDR EXP2 LOAD BEARING WALL RMVD.WALL PARTLY RPLACD W/CMU UNENGINEERED SHORING INSTLLD @CLLAR.BLDG UNSTABLE &@RISK OF COLLAPSE OWNR IMMED RTAIN NYSPE &DOB REG CNTRCTR DEMO ENDORSD-STABILZ BLDG UNDR DRCT SUPRV OF ONSITE PE.PE SU
#FEU10204IK
DOB VIOLATION - ACTIVE
Aug 2, 2022CONSTRUCTION
FTM-LANDMARK BLDG.FACADE @EXP1 BOWING OUT W/VARIOUS CRCKS APPARENT CONCRT UNDRPINNING OF ALL EXTRIOR WALLS.DETRIORATD WALLS IN AREAWAY SLOPING WOOD FRMD FLRS W/UNENGNRD JOISTS RPRS OWNR RTAIN NYSPE &CNTRCTR-EVAL BLDG &DEVLP RPR DWGS.RPR BLDG UNDR PRMT FILE BY 9/15/22.STRT WRK 10/15/22.CMPLT 10/15/20
#FEU10202IK
DOB VIOLATION - ACTIVE
Jul 14, 2020CONSTRUCTION
FTM BLDG SAFE CONDN-BRICK FACDE@EXP1 BOWING OUT OF PLACE WITH VARIOUS CRCKS.CONCR UNDERPINNIG OF ALL EXT'R WALLS.DETERIOR WALLS IN AREAWAY SLPNG WOOD FRAMED FLRS W/UNENGR'D JOIST REPRS.WATR DMG OF INT'R FINISH NEAR EXP1 WALL.OWNR RETN LIC PROFF ENG'R EVAL ENTRE BLDG&DVLP COMPREHN REPR PLNS&CONTR REP
#FEU10201IK
DOB VIOLATION - ACTIVE
Nov 13, 2007LANDMARK

#08-0359
DOB VIOLATION - ACTIVE
Aug 21, 1997CONSTRUCTION

#02B01
DOB VIOLATION - ACTIVE
Aug 21, 1997CONSTRUCTION

#02B01
VIOLATION UNSERVED ECB-ACTIVE
DOB NOW Safety (0)

None open.

HPD (41) · C 12 · B 16 · A 8
IssuedClassViolationCorrect by
Nov 15, 2023I§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID R—
Feb 15, 2022I§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID R—
Nov 2, 2022I§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID R—
Nov 22, 2024I§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID R—
Nov 17, 2025I§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID R—
Apr 29, 2026A(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.Aug 2, 2026
Jun 4, 2025A(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.Sep 7, 2025
Apr 1, 2024A(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.Jul 5, 2024
Mar 15, 2023A(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.Jun 18, 2023
Feb 15, 2022A(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.May 21, 2022
Jul 9, 2020BApt 9 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 1st ROOM FROM NORTH LOCATED AT APT 9, 2nd STORY, 1st APARTMENT FROM WEST AT NORTHAug 13, 2020
Jul 9, 2020CApt 9 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 9, 2nd STORY, 1st APARTMENT FROM WEST AT NORTHAug 4, 2020
Jul 9, 2020BApt 9 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR EAST WALL IN THE 1st ROOM FROM EAST LOCATED AT APT 9, 2nd STORY, 1st APARTMENT FROM WEST AT NORTHAug 13, 2020
Jul 9, 2020CHMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF RODENTS RATS AT REAR YARDAug 4, 2020
Jul 9, 2020C§ 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE HOUSE HOLD ITEMS AT ROOFJul 15, 2020
May 30, 2013BApt 8 · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR EAST WALL IN THE 2nd ROOM FROM EAST AT SOUTH LOCATED AT APT 8, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTHJul 4, 2013
May 30, 2013BApt 8 · SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTER BALANCE AT UPPER SASH WINDOW IN THE 2nd ROOM FROM EAST AT SOUTH LOCATED AT APT 8, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTHJul 4, 2013
Jul 1, 2008BD26-10.01 ADM CODE REPLACE WITH NEW THE MISSING BALUSTERS OF BALUSTRADE OF PUBLIC HALL STAIRS.Aug 5, 2008
Jul 1, 2008AD26-10.01 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE UPPER WINDOW SASH 3RD STY PUBLIC HALL.Oct 4, 2008
Jul 1, 2008AD26-10.01 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR NORTH WALL 1ST STY APT REAR NORTH ROOM AT BOTTOM CENTER.Oct 4, 2008
Jul 1, 2008BD26-10.01 ADM CODE PROPERLY SECURE THE LOOSE BALUSTRADE OF PUBLIC HALL STAIRS ALL STYS.Aug 5, 2008
Jul 1, 2008BD26-10.01 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE SCUTTLE COVER AT ROOF.Aug 5, 2008
Aug 16, 2007BApt 9 · SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE AND/OR REPLACE UPPER AND LOWER SASHES WINDOW 2 STY APT 9 THRU OUT. LOCATED AT APT 9Sep 20, 2007
Aug 16, 2007CApt 9 · SECTION 27-2005 ADM CODE MAKE SAFE BY PROPERLY REPAIRING THE STRUCTURAL DEFECT MASONRY FLOOR CRACKED AND SLANTING APPROX 3 2 STY APT 9 BATHROOM DOB 1055110. LOCATED AT APT 9Aug 22, 2007
Aug 16, 2007CApt 9 · SECTION 27-2005 ADM CODE MAKE SAFE BY PROPERLY REPAIRING THE STRUCTURAL DEFECT WOOD FLOOR SLANTING APPROX 3 EAST TO WEST 2 STY APT 9 SOUTH ROOM DOB 1055110. LOCATED AT APT 9Aug 22, 2007
Aug 16, 2007CApt 9 · SECTION 27-2005 ADM CODE MAKE SAFE BY PROPERLY REPAIRING THE STRUCTURAL DEFECT WOOD FLOOR SLANTING APPROX 3 NORTH TO SOUTH 2 STY APT 9 WEST ROOM DOB 1055110. LOCATED AT APT 9Aug 22, 2007
Aug 16, 2007CApt 9 · SECTION 27-2005 ADM CODE MAKE SAFE BY PROPERLY REPAIRING THE STRUCTURAL DEFECT WOOD FLOOR SLANTING APPROX 3 EAST TO WEST 2 STY APT 9 KITCHEN DOB 1055110. LOCATED AT APT 9Aug 22, 2007
Aug 16, 2007CApt 11 · SECTION 27-2018 ADM CODE ABATE THE NUISANCE CONSISTING OF RODENTS RATS AT BASEMENT APT 11. LOCATED AT APT 11Aug 22, 2007
Aug 16, 2007BApt 11 · SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CEMENT CEILING AT CEILING WEST ROOM BASEMENT STY APT 11. LOCATED AT APT 11Sep 20, 2007
Aug 16, 2007BSECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE WOOD FLOOR WHERE REQUIRED ALL STYS PUBLIC HALL.Sep 20, 2007
Aug 16, 2007CApt 11 · SECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF CONCEALED LEAK AT CEILING EAST ROOM BASEMENT STY APT 11. LOCATED AT APT 11Aug 22, 2007
Aug 16, 2007BApt 11 · SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CEMENT CEILING AT EAST ROOM BASEMENT APT 11. LOCATED AT APT 11Sep 20, 2007
Aug 16, 2007CSECTION 27-2005 ADM CODE MAKE SAFE BY PROPERLY REPAIRING THE STRUCTURAL DEFECT REAR WALLS REMOVED AND SOUTH WALL SEPERATED FROM ADJACENT BLDG DOB# 1051231.Aug 22, 2007
Aug 16, 2007CSECTION 27-2005 ADM CODE MAKE SAFE BY PROPERLY REPAIRING THE STRUCTURAL DEFECT EXTERIOR WALL AT REAR MISSING AT BASEMENT TO ROOF DOB# 1055710.Aug 22, 2007
Aug 16, 2007BSECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF CONSTRUCTION TARPAULIN OBSTRUCTING REAR BLDG BASEMENT TO ROOF.Sep 20, 2007
Aug 16, 2007BSECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF UNUSED WOOD SCAFFOLDING AT REAR BLDG BASEMENT TO ROOF.Sep 20, 2007
Aug 16, 2007BSECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF BATHTUB EXPOSED TO ELEMENTS REAR BLDG 3 STY APT.Sep 20, 2007
Aug 16, 2007CSECTION 27-2005 ADM CODE MAKE SAFE BY PROPERLY REPAIRING THE STRUCTURAL DEFECT WOOD FLOORS AND STAIRS SLANTING ALL STYS PUBLIC HALL DOB 1055710.Aug 22, 2007
Aug 16, 2007BSECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF EXPOSED ELECTRICAL WIRES WALL FIXTURE ALL STYS PUBLIC HALL.Sep 20, 2007
Aug 16, 2007BApt 9 · SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING 2 STY APT 9 MCKENNA. LOCATED AT APT 9Sep 20, 2007
Aug 16, 2007AApt 9 · SECTION 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS SINK 2 STY APT 9 KITCHEN. LOCATED AT APT 9Nov 19, 2007

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 17, 2026, 5:06 PM ET. BBL 1005930047.

Look up another building