Brooklyn · Block 2457 · Lot 34 · 11211

159 Broadway

26 floors · 112,041 sq ft · built 2019 · class H9 · owner of record: Broadway Corner Bedford Llc

5open violations
$31,250ECB/OATH penalties owed
0HPD class C (immediately hazardous)
191dto Energy and water benchmarking

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 70 days
Keep the report on file (not filed with DOB)
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 112,041 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 191 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 191 days
Annual filing
Energy audit and retro-commissioning (2027) Likely applies
Local Law 87 · Calendar year 2027
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 2457). Agency page

Dec 31, 2027
in 435 days
Next due 2027
Facade inspection report (Cycle 10B) Applies
Local Law 11 / FISP · Feb 21, 2026 to Feb 21, 2028
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 0, 7 or 8 are in sub-cycle 10B. Agency page

Feb 21, 2028
in 487 days
No Cycle 10 report on record yet
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 801 days
Next cycle year 2028

Open violations

ECB / OATH (10) · $31,250 owed
IssuedViolationHearingBalance
Oct 15, 2026Construction CLASS - 1
AT THE TIME OF INSPECTION, A PROPOSED 12-STORY NEW BUILDING WAS AN ACTIVE JOB SITE. EXCESSIVE DEBRIS THROUGHOUT THE CELLAR CREATED FIRE, TRIPPING, AND RODENT INFESTATION HAZARDS. STOP ALL WORK THE ENTIRE JOB S
#39560607P
Dec 23, 2026
PENDING
$2,500
Oct 15, 2026Construction CLASS - 1
AT THE TIME OF INSPECTION, A PROPOSED 12-STORY NEW BUILDING AN ACTIVE JOB SITE. WORKERS PERFORMING REBAR OPERATIONS ON THE WORKING DECK WERE OBSERVED WITHOUT ADEQUATE GUARDRAILS AT MULTIPLE LOCATIONS, CREATING
#39560608R
Dec 23, 2026
PENDING
$5,000
Oct 15, 2026Unknown CLASS - 2
3301.2 AT THE TIME OF INSPECTION, A PROPOSED 12-STORY NEW BUILDING ACTIVE JOB SITE. MULTIPLE UNCAPPED REBARS WERE OBSERVED, CREATING AN IMMEDIATE HAZARD TO WORKERS AND PERSONNEL ENTERING THE AREA. STOP ALL WORK
#39560609Z
Dec 23, 2026
PENDING
$2,500
Oct 15, 2026Unknown CLASS - 2
3307.2.6 12-STORY BUILDING HAD A DELIVERY TRUCK UNLOADING MATERIALS IN THE EXP# 1 WORK/ STORAGE ZONE. WITH MISSING CHINNING FENCE ON TOP OF YODAKS BARRIER. JERSEY BARRIERS OBSTRUCTED THE PEDESTRIAN WALKWAY, RE
#39560610X
Dec 23, 2026
PENDING
$2,500
Jun 2, 2026Construction CLASS - 1
UPON INSPECTION OF A NON-ACTIVE 26 STORY NB I OBSERVED UNSAFE AND POTENTIALLY HAZARDOUS HOUSEKEEPING PRACTICES. LARGE PILES OF COMBUSTIBLE MATERIAL/DEBRIS STORED ON SITE (FIRE HAZARD). BUILD UP TRASH ON SITE AN
#39554934L
Mar 5, 2027
$2,500
Dec 9, 2022Construction CLASS - 2
A-8, CONSTRUCION FENCE LEANING AND COLLAPSING ONTO SIDEWALK NOT INSTALLED PLUMB AND BRACED WITH CHAIN. CONSTRUCTION FENCE COVERED WITH ARTIFICIAL FLOWERS ON ENTIRE EXPOSURE-RECURRING CONDITION., COMPLY WITH COD
#39075454Y
Feb 15, 2023
DEFAULT
$2,500
Nov 7, 2022Construction CLASS - 2
IT WAS OBSERVED CONSTRUCTION FENCE AT EXPOSURE 1 OF NEW BUILDING JOBSITE. UPON REVIEW ON DOB NOW IT WAS OBSERVED THAT THE SAID CONSTRUCTION FENCE PERMIT IS EXPIRED SINCE 8-30-2021.RENEW PERMIT
#39508839X
Mar 15, 2023
DEFAULT
$3,125
Feb 15, 2022Construction CLASS - 2
JOBSITE FENCE NOT CONSTRUCTED OR MAINTAINED PURSUANT TO SUBSECTION.AT THE TIME OF INSPECTION ON AN ACTIVE JOBSTE,I OBSERVED A CONSTRUCTION FENCE AT EXP1,2,AND 4 COVER WITH AN ARTIFICAL PLANT BLOCKING VIEWING PA
#35592743K
Jul 6, 2022
DEFAULT
$5,000
Jan 27, 2022Construction CLASS - 2
TEMPORARY CONSTRUCTION EQUIPMENT ON SITE:EXPIRED PERMIT:AS NOTED AT TIME OF MY INSPECTION OBSERVED THAT JOB SITE WAS CLOSED,HOWEVER A REVIEWING THERE PERMITS SAW THAT FENCE PERMIT#B00034947-I1-FN ISSUED ON 9/8/
#35640313Y
Jun 8, 2022
DEFAULT
$3,125
Jun 8, 2021Construction CLASS - 2
JOB-SITE FENCE NOT CONSTRUCTED OR MAINTAINED PURSUANT TO SUBSECTION.NOTED:AT TIME OF MY INSPECTION OF A NEW 25 STORIE BUILDING,CONSTRUCTION IN PROGRESS.AT THE FOUNDATION PHASE SITE CLOSED AT TIME OF INSPECTION
#35557459J
Oct 20, 2021
DEFAULT
$2,500
DOB (0)

None open.

DOB NOW Safety (1)
IssuedViolationStatus
Jan 8, 2026Gas Piping - LL152 FTF-PL-PER
Cycle 2, Sub-cycle A (premises is in Community District 1)
Active
HPD (0)

None open.

Issued in the last 120 days

DateSourceWhatNow
Oct 15, 2026ECBConstruction: AT THE TIME OF INSPECTION, A PROPOSED 12-STORY NEW BUILDING WAS AN ACTIVE JOB SITE. EXCESSIVE DEBRIS THROUGHOUT THE CELLAR CREATED FIRE, TRIPPING, AND RODENT INFESTATION HAZARDS. STOP ALL WORK THE ENTIRE JOB SOpen
Oct 15, 2026ECBConstruction: AT THE TIME OF INSPECTION, A PROPOSED 12-STORY NEW BUILDING AN ACTIVE JOB SITE. WORKERS PERFORMING REBAR OPERATIONS ON THE WORKING DECK WERE OBSERVED WITHOUT ADEQUATE GUARDRAILS AT MULTIPLE LOCATIONS, CREATINGOpen
Oct 15, 2026ECBUnknown: 3301.2 AT THE TIME OF INSPECTION, A PROPOSED 12-STORY NEW BUILDING ACTIVE JOB SITE. MULTIPLE UNCAPPED REBARS WERE OBSERVED, CREATING AN IMMEDIATE HAZARD TO WORKERS AND PERSONNEL ENTERING THE AREA. STOP ALL WORKOpen
Oct 15, 2026ECBUnknown: 3307.2.6 12-STORY BUILDING HAD A DELIVERY TRUCK UNLOADING MATERIALS IN THE EXP# 1 WORK/ STORAGE ZONE. WITH MISSING CHINNING FENCE ON TOP OF YODAKS BARRIER. JERSEY BARRIERS OBSTRUCTED THE PEDESTRIAN WALKWAY, REOpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 22, 2026, 11:33 AM ET. BBL 3024570034.