9 floors · 26,057 sq ft · built 1911 · class H3 · owner of record: New Hampton Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 44 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 26,057 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 165 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 165 days | Annual filing |
| Facade inspection report (Cycle 10B) Applies Local Law 11 / FISP · Feb 21, 2026 to Feb 21, 2028 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 0, 7 or 8 are in sub-cycle 10B. DOB facade records for this building show $511,380 in late-filing or failure-to-file penalties. Agency page | Feb 21, 2028 in 461 days | No Cycle 10 report on record yet |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 5 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1140 days | Next cycle year 2029 |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-06-23 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Nov 9, 2026 | Elevators CLASS - 1 CLASS 1 C/U: ROPE GRIPPER SAFETY DEVICE DISABLED BY AN INSERTED PIN, PREVENTING ITS NORMAL ENGAGEMENT. THIS CONDITION RENDERS A CRITICAL SAFETY DEVICE INOPERATIVE AND MAY PREVENT THE DEVICE FROM GRIPPING THE HO #39211099M | Jan 14, 2027 PENDING | $1,250 |
| Aug 1, 2025 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING FACADE WALL"S" AND APPURTENANCES. NOTE: AT THE TIME OF INSPECTION I OBSERVED AT EX #2, EAST ELEVATION, DISLODGED/UNSECURED METAL PANEL AT THE 9TH FLOOR. AT EX #4, SOUTH ELEVATION, U #35718193X | Apr 16, 2026 IN VIOLATION | $5,000 |
| Apr 30, 2025 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING WALL OR APPURTENANCES. NOTES: AT THE TIMEOF INSPECTION OBSERVED BROKEN GLASS WINDOW AT EXP #3(SOUTH ELEVATION) 9TH FLOOR. REMEDY: MAINTAIN EXTERIOR BUILDING FACADE AND APPURTENANCES #35716644R | Feb 12, 2026 IN VIOLATION | $5,000 |
| Mar 7, 2025 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: NO FIRE STOPPING PER BC 712.3 (2014 CODE); 27-345; BC 711.2.4 (2022 CODE. OBSERVED HOLE PENETRATION AT TELECOM ROOM LOCATED AT BASEMENT. (AC INSTALLED INTO #39140807Z | Jun 16, 2026 IN VIOLATION | $2,500 |
| May 17, 2024 | Construction CLASS - 1 UNLAWFUL ACTS: FAILURE TO COMPLY WITH COMMISSIONER'S ORDER AS STATED IN ECB# 39081915Z ISSUED ON 03/20/2023 FOR FAILURE TO PROPERLY TERMINATE CONDUCTORS, AND FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28-201. #39114691R | Jan 9, 2025 IN VIOLATION | $2,500 |
| May 17, 2024 | Construction CLASS - 1 UNLAWFUL ACTS: FAILURE TO COMPLY WITH COMMISSIONER'S ORDER AS STATED IN ECB# 39081914R ISSUED ON 03/20/2023 FOR IMPROPER GROUNDING OF ELECTRICAL SYSTEMS AND FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28-201.1 #39114693K | Jan 9, 2025 IN VIOLATION | $2,500 |
| May 17, 2024 | Unknown CLASS - 1 I OBSERVED IN THE BASEMENT ELECTRICAL ROOM THE DISCONNECT SWITCH LABELED "PASTA LOVERS" WITH 3 CONDUCTORS ON THE LOAD SIDE INSTALLED UNDER A SINGLE LUG. AS PER EC 110.14A MULTIPLE CONDUCTORS SHALL NOT UNDER ONE #39114692Z | Jan 9, 2025 IN VIOLATION | $4,000 |
| Feb 20, 2024 | Construction CLASS - 1 UNLAWFUL ACTS: FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION# 39081915Z ISSUED ON 03/20/2023 AND TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28-201.1 AND 1RCNY 102-01. FAILUR #39106315N | Sep 24, 2024 IN VIOLATION | $1,250 |
| Feb 20, 2024 | Construction CLASS - 1 UNLAWFUL ACTS: FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION#39081914R ISSUED ON 03/20/2023 AND TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28-201.1 AND 1RCNY 102-01. FAILURE #39106314L | Sep 24, 2024 IN VIOLATION | $1,250 |
| Jan 16, 2024 | Local Law CLASS - 2 FAILURE TO FILE ACCEPTABLE AMENDED CYCLE 9B REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL FACADES REPORT REQUIRED BY 28-302.5 FOR CONTROL #903120. REMEDY: FILE ACCEPTABLE REPORT. #37026704Y | May 30, 2024 IN VIOLATION | $625 |
| Mar 20, 2023 | Unknown CLASS - 2 I OBSERVED IN THE ELECTRICAL THE IMPROPER INSTALLATION OF A 2" EMT SUPPLYING POWER TO AN UNLABELED DISCONNECT SWITCH, THE CONDUIT IS PASSING THROUGH AN OPENING AND NOT MECHANICALLY CONNECTED AS REQUIRED ALL ELE #39081917M | Dec 14, 2023 IN VIOLATION | $1,200 |
| Mar 20, 2023 | Unknown CLASS - 1 I OBSERVED FAILURE TO PROPERLY BOND AND GROUND ELECTRICAL SYSTEMS, THE SERVICE GROUND EXTENDED BEYOND THE LOAD SIDE OF THE DISCONNECT ON THE RIGHT SIDE OF THE ROOM AND THERE IS A BROKEN GROUND TO THE SWITCH ON #39081914R | Dec 14, 2023 IN VIOLATION | $4,800 |
| Mar 20, 2023 | Unknown CLASS - 2 I OBSERVED IN THE 7TH FLOOR ELECTRIC CLOSET AND THE MAIN ELECTRIC ROOM THE INSTALLATION OF OVERCURRENT DEVICES ABOVE THE ALLOWABLE HEIGHT OF 6' 7" FROM THE FLOOR LEVEL. PHOTOS TAKEN; EC 240.24A, COMPLY WITH EC #39081912N | Dec 14, 2023 IN VIOLATION | $800 |
| Mar 20, 2023 | Unknown CLASS - 2 I OBSERVED ON THE ROOFTOP AND THE GROUND LEVEL AT EXPOSURE #3 CONDUITS BROKEN AND UNSECURED WITH EXPOSED CONDUCTORS. ALSO NOTED CONDUITS IN BASEMENT ELECTRICAL ROOM, WATER PUMP ROOM. PHOTOS TAKEN., SECURE/SUPPO #39081916K | Dec 14, 2023 IN VIOLATION | $800 |
| Mar 20, 2023 | Unknown CLASS - 2 I OBSERVED IN THE SIDE AND REAR COURTYARDS/ALLEYWAYS THE UNPERMITTED USE OF FLEXIBLE CORDS AS PERMANENT WIRING BETWEEN THE OUTSIDE A.C. UNIT AND THE INTERIOR FAN UNIT. AS PER EC 400.8 FLEXIBLE CORD IS NOT PERMI #39081913P | Dec 14, 2023 IN VIOLATION | $800 |
| Mar 20, 2023 | Unknown CLASS - 2 I OBSERVED IN THE ELECTRICAL ROOM FAILURE TO PROTECT THE ELECTRICAL EQUIPMENT FROM DETERIORATING AGENTS, I NOTED THE RACEWAYS, CONDUITS AND TERMINAL LUGS ON THE INTERIOR OF THE DISCONNECT SWITCHES IN AN ADVANCE #39081911L | Dec 14, 2023 IN VIOLATION | $800 |
| Mar 20, 2023 | Unknown CLASS - 1 I OBSERVED IN A SERVICE DISCONNECT SWITCH LABELED "PASTA LOVERS" WITH THREE LOAD SIDE CONDUCTORS IMPROPERLY TERMINATED UNDER A SINGLE LUG. MULTIPLE CONDUCTORS SHALL NOT BE UNDER A SINGLE UNLESS THE LUG IS MANUF #39081915Z | Dec 14, 2023 IN VIOLATION | $1,600 |
| Mar 20, 2023 | Unknown CLASS - 2 I OBSERVED IN THE ELECTRICAL ROOM SEVERAL DISCONNECT SWITCHES WITHOUT LABELING AS REQUIRED PER EC 110.22 FOR ALL DISCONNECT SWITCHES TO BE PROPERLY IDENTIFIED. ALSO NOTED THROUGHOUT THE BUILDING MULTIPLE PANELS #39081910J | Dec 14, 2023 IN VIOLATION | $800 |
| Mar 20, 2023 | Unknown CLASS - 2 I OBSERVED IN THE WATER PUMP AND ELECTRICAL ROOMS THE IMPROPER INSTALLATION OF CONDUITS JUNCTION BOXES AND LIGHTS. NOTED THE EQUIPMENT IS HANGING IN FREE AIR AND UNSUPPORTED AS REQUIRED OF ELECTRICAL SYSTEMS. P #39081908K | Dec 14, 2023 IN VIOLATION | $250 |
| Dec 8, 2022 | Construction CLASS - 2 OBSERVED: - AT ROOF LEVEL, ELEVATED WATER STORAGE TANK ON STEEL STRUCTURE WITH DETERIORATION DUE TO CORROSION, BROKEN SUPPORT ELEMENTS, WHICH DO NOT GUARANTEE THE INTEGRITY AND RESISTANCE OF THE STRUCTURE., REP #39075313K | Aug 17, 2023 IN VIOLATION | $312 |
None open.
| Issued | Violation | Status |
|---|---|---|
| Mar 6, 2026 | Energy Grade - LL33 FTP-EN-EGRDEA FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER AD CODE SEC. 28-309.12.3 | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2018 Cat1 Test Affirmation of Correction | Active |
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Nov 9, 2026 | ECB | Elevators: CLASS 1 C/U: ROPE GRIPPER SAFETY DEVICE DISABLED BY AN INSERTED PIN, PREVENTING ITS NORMAL ENGAGEMENT. THIS CONDITION RENDERS A CRITICAL SAFETY DEVICE INOPERATIVE AND MAY PREVENT THE DEVICE FROM GRIPPING THE HO | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)