Manhattan · Block 1010 · Lot 55 · 10019

158 West 58 Street

9 floors · 26,057 sq ft · built 1911 · class H3 · owner of record: New Hampton Llc

3open violations
$38,037ECB/OATH penalties owed
0HPD class C (immediately hazardous)
165dto Energy and water benchmarking

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 44 days
Keep the report on file (not filed with DOB)
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 26,057 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 165 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 165 days
Annual filing
Facade inspection report (Cycle 10B) Applies
Local Law 11 / FISP · Feb 21, 2026 to Feb 21, 2028
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 0, 7 or 8 are in sub-cycle 10B. DOB facade records for this building show $511,380 in late-filing or failure-to-file penalties. Agency page

Feb 21, 2028
in 461 days
No Cycle 10 report on record yet
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 5 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1140 days
Next cycle year 2029
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-06-23 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (20) · $38,037 owed
IssuedViolationHearingBalance
Nov 9, 2026Elevators CLASS - 1
CLASS 1 C/U: ROPE GRIPPER SAFETY DEVICE DISABLED BY AN INSERTED PIN, PREVENTING ITS NORMAL ENGAGEMENT. THIS CONDITION RENDERS A CRITICAL SAFETY DEVICE INOPERATIVE AND MAY PREVENT THE DEVICE FROM GRIPPING THE HO
#39211099M
Jan 14, 2027
PENDING
$1,250
Aug 1, 2025Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING FACADE WALL"S" AND APPURTENANCES. NOTE: AT THE TIME OF INSPECTION I OBSERVED AT EX #2, EAST ELEVATION, DISLODGED/UNSECURED METAL PANEL AT THE 9TH FLOOR. AT EX #4, SOUTH ELEVATION, U
#35718193X
Apr 16, 2026
IN VIOLATION
$5,000
Apr 30, 2025Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING WALL OR APPURTENANCES. NOTES: AT THE TIMEOF INSPECTION OBSERVED BROKEN GLASS WINDOW AT EXP #3(SOUTH ELEVATION) 9TH FLOOR. REMEDY: MAINTAIN EXTERIOR BUILDING FACADE AND APPURTENANCES
#35716644R
Feb 12, 2026
IN VIOLATION
$5,000
Mar 7, 2025Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: NO FIRE STOPPING PER BC 712.3 (2014 CODE); 27-345; BC 711.2.4 (2022 CODE. OBSERVED HOLE PENETRATION AT TELECOM ROOM LOCATED AT BASEMENT. (AC INSTALLED INTO
#39140807Z
Jun 16, 2026
IN VIOLATION
$2,500
May 17, 2024Construction CLASS - 1
UNLAWFUL ACTS: FAILURE TO COMPLY WITH COMMISSIONER'S ORDER AS STATED IN ECB# 39081915Z ISSUED ON 03/20/2023 FOR FAILURE TO PROPERLY TERMINATE CONDUCTORS, AND FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28-201.
#39114691R
Jan 9, 2025
IN VIOLATION
$2,500
May 17, 2024Construction CLASS - 1
UNLAWFUL ACTS: FAILURE TO COMPLY WITH COMMISSIONER'S ORDER AS STATED IN ECB# 39081914R ISSUED ON 03/20/2023 FOR IMPROPER GROUNDING OF ELECTRICAL SYSTEMS AND FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28-201.1
#39114693K
Jan 9, 2025
IN VIOLATION
$2,500
May 17, 2024Unknown CLASS - 1
I OBSERVED IN THE BASEMENT ELECTRICAL ROOM THE DISCONNECT SWITCH LABELED "PASTA LOVERS" WITH 3 CONDUCTORS ON THE LOAD SIDE INSTALLED UNDER A SINGLE LUG. AS PER EC 110.14A MULTIPLE CONDUCTORS SHALL NOT UNDER ONE
#39114692Z
Jan 9, 2025
IN VIOLATION
$4,000
Feb 20, 2024Construction CLASS - 1
UNLAWFUL ACTS: FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION# 39081915Z ISSUED ON 03/20/2023 AND TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28-201.1 AND 1RCNY 102-01. FAILUR
#39106315N
Sep 24, 2024
IN VIOLATION
$1,250
Feb 20, 2024Construction CLASS - 1
UNLAWFUL ACTS: FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION#39081914R ISSUED ON 03/20/2023 AND TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28-201.1 AND 1RCNY 102-01. FAILURE
#39106314L
Sep 24, 2024
IN VIOLATION
$1,250
Jan 16, 2024Local Law CLASS - 2
FAILURE TO FILE ACCEPTABLE AMENDED CYCLE 9B REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL FACADES REPORT REQUIRED BY 28-302.5 FOR CONTROL #903120. REMEDY: FILE ACCEPTABLE REPORT.
#37026704Y
May 30, 2024
IN VIOLATION
$625
Mar 20, 2023Unknown CLASS - 2
I OBSERVED IN THE ELECTRICAL THE IMPROPER INSTALLATION OF A 2" EMT SUPPLYING POWER TO AN UNLABELED DISCONNECT SWITCH, THE CONDUIT IS PASSING THROUGH AN OPENING AND NOT MECHANICALLY CONNECTED AS REQUIRED ALL ELE
#39081917M
Dec 14, 2023
IN VIOLATION
$1,200
Mar 20, 2023Unknown CLASS - 1
I OBSERVED FAILURE TO PROPERLY BOND AND GROUND ELECTRICAL SYSTEMS, THE SERVICE GROUND EXTENDED BEYOND THE LOAD SIDE OF THE DISCONNECT ON THE RIGHT SIDE OF THE ROOM AND THERE IS A BROKEN GROUND TO THE SWITCH ON
#39081914R
Dec 14, 2023
IN VIOLATION
$4,800
Mar 20, 2023Unknown CLASS - 2
I OBSERVED IN THE 7TH FLOOR ELECTRIC CLOSET AND THE MAIN ELECTRIC ROOM THE INSTALLATION OF OVERCURRENT DEVICES ABOVE THE ALLOWABLE HEIGHT OF 6' 7" FROM THE FLOOR LEVEL. PHOTOS TAKEN; EC 240.24A, COMPLY WITH EC
#39081912N
Dec 14, 2023
IN VIOLATION
$800
Mar 20, 2023Unknown CLASS - 2
I OBSERVED ON THE ROOFTOP AND THE GROUND LEVEL AT EXPOSURE #3 CONDUITS BROKEN AND UNSECURED WITH EXPOSED CONDUCTORS. ALSO NOTED CONDUITS IN BASEMENT ELECTRICAL ROOM, WATER PUMP ROOM. PHOTOS TAKEN., SECURE/SUPPO
#39081916K
Dec 14, 2023
IN VIOLATION
$800
Mar 20, 2023Unknown CLASS - 2
I OBSERVED IN THE SIDE AND REAR COURTYARDS/ALLEYWAYS THE UNPERMITTED USE OF FLEXIBLE CORDS AS PERMANENT WIRING BETWEEN THE OUTSIDE A.C. UNIT AND THE INTERIOR FAN UNIT. AS PER EC 400.8 FLEXIBLE CORD IS NOT PERMI
#39081913P
Dec 14, 2023
IN VIOLATION
$800
Mar 20, 2023Unknown CLASS - 2
I OBSERVED IN THE ELECTRICAL ROOM FAILURE TO PROTECT THE ELECTRICAL EQUIPMENT FROM DETERIORATING AGENTS, I NOTED THE RACEWAYS, CONDUITS AND TERMINAL LUGS ON THE INTERIOR OF THE DISCONNECT SWITCHES IN AN ADVANCE
#39081911L
Dec 14, 2023
IN VIOLATION
$800
Mar 20, 2023Unknown CLASS - 1
I OBSERVED IN A SERVICE DISCONNECT SWITCH LABELED "PASTA LOVERS" WITH THREE LOAD SIDE CONDUCTORS IMPROPERLY TERMINATED UNDER A SINGLE LUG. MULTIPLE CONDUCTORS SHALL NOT BE UNDER A SINGLE UNLESS THE LUG IS MANUF
#39081915Z
Dec 14, 2023
IN VIOLATION
$1,600
Mar 20, 2023Unknown CLASS - 2
I OBSERVED IN THE ELECTRICAL ROOM SEVERAL DISCONNECT SWITCHES WITHOUT LABELING AS REQUIRED PER EC 110.22 FOR ALL DISCONNECT SWITCHES TO BE PROPERLY IDENTIFIED. ALSO NOTED THROUGHOUT THE BUILDING MULTIPLE PANELS
#39081910J
Dec 14, 2023
IN VIOLATION
$800
Mar 20, 2023Unknown CLASS - 2
I OBSERVED IN THE WATER PUMP AND ELECTRICAL ROOMS THE IMPROPER INSTALLATION OF CONDUITS JUNCTION BOXES AND LIGHTS. NOTED THE EQUIPMENT IS HANGING IN FREE AIR AND UNSUPPORTED AS REQUIRED OF ELECTRICAL SYSTEMS. P
#39081908K
Dec 14, 2023
IN VIOLATION
$250
Dec 8, 2022Construction CLASS - 2
OBSERVED: - AT ROOF LEVEL, ELEVATED WATER STORAGE TANK ON STEEL STRUCTURE WITH DETERIORATION DUE TO CORROSION, BROKEN SUPPORT ELEMENTS, WHICH DO NOT GUARANTEE THE INTEGRITY AND RESISTANCE OF THE STRUCTURE., REP
#39075313K
Aug 17, 2023
IN VIOLATION
$312
DOB (0)

None open.

DOB NOW Safety (2)
IssuedViolationStatus
Mar 6, 2026Energy Grade - LL33 FTP-EN-EGRDEA
FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER AD CODE SEC. 28-309.12.3
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2018 Cat1 Test Affirmation of Correction
Active
HPD (0)

None open.

Issued in the last 120 days

DateSourceWhatNow
Nov 9, 2026ECBElevators: CLASS 1 C/U: ROPE GRIPPER SAFETY DEVICE DISABLED BY AN INSERTED PIN, PREVENTING ITS NORMAL ENGAGEMENT. THIS CONDITION RENDERS A CRITICAL SAFETY DEVICE INOPERATIVE AND MAY PREVENT THE DEVICE FROM GRIPPING THE HOOpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 17, 2026, 6:03 PM ET. BBL 1010100055.