Manhattan · Block 1628 · Lot 57 · 10029

1578 Lexington Avenue

class V1 · owner of record: Lexington Two Holdings Llc

6open violations
$28,680ECB/OATH penalties owed
0HPD class C (immediately hazardous)
—no dated deadlines found

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

We couldn't find building attributes for this lot, so no deadlines are listed.

Open violations

ECB / OATH (9) · $28,680 owed
IssuedViolationHearingBalance
Aug 18, 2026Site Safety CLASS - 1
OBS. WORK IN PROGRESS AT 13-STORY NEW BLDG. REQ'D BC CH. 33 SUSPENDED-SCAFFOLD RECORDS WERE NOT MAINTAINED ON SITE OR MADE READILY AVAILABLE. UPON REQUEST, COMPETENT PERSON FAILED TO PROVIDE PLATFORM MFR. SPECS
#39558089L
May 13, 2027
PENDING
$2,500
Aug 18, 2026Construction CLASS - 2
3314.3.4 OBS. SUPPORTED SCAFFOLD AND PLATFORMS INSTALLED AT EXPS. 1 & 4 WITHOUT REQ'D SEALED PE LOAD-IMPOSED LETTER. UPON REQUEST, COMPETENT PERSON FAILED TO PROVIDE DOCUMENTATION VERIFYING THE SUPPORTING STRUC
#39558092M
Oct 22, 2026
IN VIOLATION
$1,250
Aug 18, 2026Unknown CLASS - 1
3314.15.2 OBS. SUSPENDED SCAFFOLDS IN USE/READILY AVAILABLE FOR USE WITH STIRRUP/HOIST ASSEMBLIES IMPROPERLY FITTED AND POSITIONED. REQ'D 6-18-IN. END PLACEMENT WAS NOT MAINTAINED. ON 40-FT MODULAR PLATFORM, ST
#39558090Z
May 13, 2027
PENDING
$5,000
May 7, 2026Unknown CLASS - 1
AT TIME OF INSPECTION OF NEW 13 STORY BUILDING IN PROGRESS WHERE WORKER INJURED IN CELLAR WHEN WORKING ON UNSAFE PLATFORM WITHOUT PROPER ACCESS AS PER 3301.2 CAUSING INJURY AND HOSPITAL VISIT WITH RIGHT KNEE PA
#39553894L
Feb 11, 2027
$5,000
May 7, 2026Construction CLASS - 1
AT TIME OF INSPECTION OF 13 STORY NEW BUILDING IN PROGRESS WHERE INCIDENT OCCURRED WHEN STRUCTURE TECH EMPLOYEE CUTTING PILES AT CELLAR LEVEL CLIMBING FROM UNSAFE TEMPORARY PLATFORM(APPROXIMATELY 3-4') FROM BUR
#39553878L
Feb 11, 2027
$2,500
Apr 10, 2026Construction CLASS - 1
AT TIME OF INSPECTION, CONCRETE FINISHING OPERATIONS OBSERVED TAKING PLACE INCLUDING THE GAS-POWERED MECHANICAL TROWEL FINISHING THE CONCRETE FLOOR CREATING AN ABUNDANCE OF NOISE WITH APPROXIMATELY 3 WORKERS ON
#39184146P
Jan 28, 2027
$2,500
Mar 13, 2026Construction CLASS - 2
NOTE: AT TIME OF INSPECTION OF AN ACTIVE CONSTRUCTION SITE. I OBSERVED AT EXPO# 1 A SIDEWALK SHED INSTALLED WITH THE VERTICAL MEMBERS LOCATED ON THE ROADWAY/STREET WITHOUT THE REQUIRED DOT PERMIT AS PER 3307.6.
#39551697N
Mar 25, 2027
DEFAULT
$2,430
Feb 14, 2026Unknown CLASS - 2
OBSERVED CONSTRUCTION SITE OVER 5,000 SQ. FT. WITHOUT A LICENSED SECURITY GUARD/WATCHPERSON. INDIVIDUAL ON SITE PRESENTED FDNY CARD ONLY AND NO VALID SECURITY GUARD LICENSE. REQUIRED SITE SECURITY NOT PROPERLY
#39550389R
Nov 24, 2026
$2,500
Feb 14, 2026Unknown CLASS - 1
OBSERVED PEDESTRIAN WALKWAY OBSTRUCTED DUE TO LIMITED CLEARANCE BETWEEN FENCE AND EXISTING TREES, WITH PARKED VEHICLES AND PILED SNOW FURTHER RESTRICTING ACCESS. CONDITION PREVENTS WHEELCHAIR ACCESSIBILITY AND
#39550390Y
Nov 24, 2026
$5,000
DOB (0)

None open.

DOB NOW Safety (0)

None open.

HPD (3) · C 0 · B 0 · A 2
IssuedClassViolationCorrect by
Nov 17, 2025I§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID R—
Apr 29, 2026A(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.Aug 2, 2026
Jun 4, 2025A(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.Sep 7, 2025

Issued in the last 120 days

DateSourceWhatNow
Aug 18, 2026ECBConstruction: OBS. SUSPENDED SCAFFOLDS IN USE/READILY AVAILABLE FOR USE AT EXPS. 3 & 4, INCL. ROOF/SETBACK LOCATIONS. MULTIPLE TIEBACK ANCHOR PLATES INSTALLED AT ROOF/SETBACKS DIFFERED FROM AND WERE NOT SHOWN ON APPROVED CD-Closed
Aug 18, 2026ECBSite Safety: OBS. WORK IN PROGRESS AT 13-STORY NEW BLDG. REQ'D BC CH. 33 SUSPENDED-SCAFFOLD RECORDS WERE NOT MAINTAINED ON SITE OR MADE READILY AVAILABLE. UPON REQUEST, COMPETENT PERSON FAILED TO PROVIDE PLATFORM MFR. SPECSOpen
Aug 18, 2026ECBConstruction: 3314.3.4 OBS. SUPPORTED SCAFFOLD AND PLATFORMS INSTALLED AT EXPS. 1 & 4 WITHOUT REQ'D SEALED PE LOAD-IMPOSED LETTER. UPON REQUEST, COMPETENT PERSON FAILED TO PROVIDE DOCUMENTATION VERIFYING THE SUPPORTING STRUCClosed
Aug 18, 2026ECBConstruction: OBS. SUPPORTED SCAFFOLD AT EXPS. 1 & 4 CONTRARY TO APPROVED PLANS. EXP. 1 TRUSSES MEASURED 18 FT VS. 16 FT REQ'D; MASONRY FRAMES USED INSTEAD OF WALK-THROUGH FRAMES, WITH 4-FT OUTRIGGERS. AT EXP. 4, W8X13 BEAMClosed
Aug 18, 2026ECBUnknown: 3314.15.2 OBS. SUSPENDED SCAFFOLDS IN USE/READILY AVAILABLE FOR USE WITH STIRRUP/HOIST ASSEMBLIES IMPROPERLY FITTED AND POSITIONED. REQ'D 6-18-IN. END PLACEMENT WAS NOT MAINTAINED. ON 40-FT MODULAR PLATFORM, STOpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 18, 2026, 8:44 AM ET. BBL 1016280057.

Look up another building