Manhattan · Block 1527 · Lot 28 · 10028

1571 2 Avenue

20 floors · 177 apartments · 189,612 sq ft · built 1963 · class D6 · owner of record: Second 82nd Corp

47open violations
$0ECB/OATH penalties owed
0HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueRegistration expired 2026-09-01
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 8 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 65 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 65 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 65 days
Annual
Annual boiler inspection (3 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-04-11 (Accepted). Agency page

Dec 31, 2026
in 65 days
3 of 3 without an accepted 2026 report yet
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 81 days
Annual
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 189,612 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 186 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 186 days
Annual filing
Energy audit and retro-commissioning (2027) Likely applies
Local Law 87 · Calendar year 2027
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 1527). Agency page

Dec 31, 2027
in 430 days
Next due 2027
Facade inspection report (Cycle 10B) Applies
Local Law 11 / FISP · Feb 21, 2026 to Feb 21, 2028
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 0, 7 or 8 are in sub-cycle 10B. DOB facade records for this building show $360,000 in late-filing or failure-to-file penalties. Agency page

Feb 21, 2028
in 482 days
No Cycle 10 report on record yet

Open violations

ECB / OATH (10)
IssuedViolationHearingBalance
Nov 12, 2024Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING'S EXTERIOR WALLS AND/OR APPURTENANCES.-ATTIME OF INSPECTION OBSERVED MULTIPLE CONCRETE BALCONIES WITH CRACKED/SPALLED CONCRETE/COATING LOCATED ON THE UNDERSIDE OF THE CONCRETE BALCO
#35686791M
Jan 16, 2025
IN VIOLATION
$0
Apr 11, 2024Local Law CLASS - 2
FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 9B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL #905722. REMEDY: SUBMIT ACCEPTABLE REQU
#37027745P
Jul 11, 2024
IN VIOLATION
$0
Mar 19, 2024Construction CLASS - 2
FAILURE TO COMPLY WITH COMMISSIONER'S ORDER CONTAINED IN SUMMONS#35548631H ISSUED ON 4/3/2021,AND FAILURE TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28.201.1 AND 1RCNY 102-01(D)(2).AN ACCEPTABLE CERTIFICAT
#37027085Z
Jun 13, 2024
IN VIOLATION
$0
Mar 14, 2023Construction CLASS - 1
OBSERVED BASEMENT IN THE LAUNDRY ROOM A FUTURE ON GAS LINE WHICH IS CONTRARY FGC 408.2, REPAIR AND/REPLACE
#39081359R
May 18, 2023
ADMIT/IN-VIO
$0
Mar 14, 2023Plumbing CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLAINT MANNER: LACK OF A SYSTEM OF AUTOMATIC SPRINKLERS WHERE REQUIRE PER BC 903.2; 27-954 I OBSERVED IN BASEMENT 10 COMMERCIAL GAS DRYERS AND NO SPRINKLER SYSTEM IN PLAC
#39081360Y
Jun 15, 2023
IN VIOLATION
$0
Apr 3, 2021Construction CLASS - 2
FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE AND APPRURTENANCES.AT TIME OF INSPECTION OBSERVED EXPOSURE#2 VARIOUS LOCATION LOSS MORTAR POINTAND CRACKS AT BRICK.EXPOSURE#3 15 FLOOR LEVEL STEP CRACKS.ALSO EXPOSUR
#35548631H
Jun 17, 2021
STIPULATION/IN-VIO
$0
Feb 17, 2021Construction CLASS - 2
SEC. 28-301.1 FAILURE TO MAINTAIN BLDG IN A CODE COMPLIANT MANNER(ACCESSIBILITY RAMP NON-COMPLIANT). NOTE: HANDICAP/ACCESSIBILITY RAMP LOATED INSIDE MAIN ENTRANCE LOBBY HAS A SLOPE STEEPER THAN 1:12 CONTRARY TO
#35546158M
Jul 29, 2021
IN VIOLATION
$0
Jan 25, 2021Construction CLASS - 1
OWNERS FAILURE TO REPAIR SWARMY CONDITIONS IN A TIMELY MANNER. ON 1-25-2021 OBSERVED EXISTING SWARMP CONDITIONS AT ROOF AREA BULKHEAD M/C ROOM PARAPET AND CHIMNEY. CONDITION EXIST AT EXPOSURE 1 EXPOSURE 2 AND 3
#35549581N
Jul 15, 2021
IN VIOLATION
$0
Jun 20, 2017Unknown CLASS - 2
FAILURE TO FILE ANNUAL CERTIFICATION THAT COOLING TOWER 1000002288 HAS BEEN INSPECTED, TESTED, AND DISINFECTED AND THAT A MAINTENANCE PLAN HAS BEEN DEVELOPED AND IMPLEMENTED BY NOVEMBER 1,2016.REM:FILE ANNUAL
#37002074M
Oct 26, 2017
IN VIOLATION
$0
Jan 2, 2007Construction Non-Hazardous
FAILURE TO MAINTAIN BLDG EXTERIOR DEFECTS NOTED AT 1ST FL. SETBACK ROOF ABOVE GROUND FL EATING & DRINKING ESTABLISHMENT KNOWN AS "SUSH GENERATION"KITCHEN EXHAUST PLENUM IS RUSTED & SEAMS ARE OPEN
#34543664P
Feb 22, 2007
STIPULATION/IN-VIO
$0
DOB (19)
IssuedViolationStatus
Jan 22, 2025FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00038
DOB VIOLATION - ACTIVE
Nov 22, 2024CONSTRUCTION
PARTIAL VACATE ORDER.AS OBSERVED THERE ARE SPALLED/LOOSE CONCRETE AT BALCONY SLABS MULTIPLE LOCATIONS ON EXPOSURES 1(NORTH ELEV) & 2 (EAST ELEV). THESE CONDITIONS HAVE THEREFORE MADE ALL FACADE BALCONIES AT NORTH & EAST ELEVATIONS UNABLE TO BE OCCUPIED. REMEDY: VACATE ALL BALCONY LINES ON EXPOSURE 1
#FA10801JP
DOB VIOLATION - ACTIVE
Nov 12, 2024CONSTRUCTION
EMERGENCY WORK ORDER DUE TO MULTIPLE CONCRETE BALCONIES LOCATED ON STR FACING ELEVATIONS, EXPOSURE 1 (NORTH ELEV) & 2 (EAST ELEV) WITH CRACK/ SPALLED CONCRETE. SOME BALCONY SLAB HAVE LOOSE/HANGING MATERIAL PRESEN REMEDY:IMMEDIATELY PROVIDE SAFETY MEASURES TO SECURE & PROTECT THE PUB & INSTALL PUB PR
#FA10802JP
DOB VIOLATION - ACTIVE
Oct 4, 2023FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00527
DOB VIOLATION - ACTIVE
Oct 4, 2023FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00526
DOB VIOLATION - ACTIVE
Feb 22, 2023NO REPORT AND / OR LATE FILING (FACADE)
FAILED TO FILE FISP CYCLE 9B TECHNICAL REPORT BY 2/21/2023
#02011
DOB VIOLATION - ACTIVE
Apr 28, 2021FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00060
DOB VIOLATION - ACTIVE
Jan 26, 2018(OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION
VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2016 CAT 1 INSP/TST
#03881
DOB VIOLATION - ACTIVE
Jan 26, 2018(OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION
VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2016 CAT 1 INSP/TST
#03880
DOB VIOLATION - ACTIVE
Jan 3, 2017(OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION
VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2015 CAT 1 INSP/TST
#03780
DOB VIOLATION - ACTIVE
Jan 3, 2017(OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION
VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2015 CAT 1 INSP/TST
#03779
DOB VIOLATION - ACTIVE
Mar 31, 2014ELEVATOR ANNUAL INSPECTION / TEST
VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2012 INSPECTION/TEST
#02414
DOB VIOLATION - ACTIVE
Mar 31, 2014ELEVATOR ANNUAL INSPECTION / TEST
VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2012 INSPECTION/TEST
#02413
DOB VIOLATION - ACTIVE
Dec 13, 2011LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2010 INSPECTION REPORT
#02502
DOB VIOLATION - ACTIVE
Aug 17, 2005CONSTRUCTION

#0802DM
DOB VIOLATION - ACTIVE
Mar 19, 2003LOCAL LAW 62/91 - BOILERS

#04528
DOB VIOLATION - ACTIVE
Nov 9, 2001CONSTRUCTION

#08JGO1
VIOLATION WORK WITHOUT PERMIT - ACTIVE
Sep 16, 1997LOCAL LAW 62/91 - BOILERS

#184209
DOB VIOLATION - ACTIVE
Feb 10, 1997LOCAL LAW 62/91 - BOILERS

#06581
DOB VIOLATION - ACTIVE
DOB NOW Safety (17)
IssuedViolationStatus
Jan 22, 2025AEUHAZ FTC-AEU-HAZ
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2022 External Inspection Affirmation of Correction for LP Device
Active
Oct 4, 2023AEUHAZ FTC-AEU-HAZ
Active
Oct 4, 2023AEUHAZ FTC-AEU-HAZ
Active
Feb 22, 2023Facades FISPNRF
CYCLE 9B NO REPORT FILED
Active
Apr 28, 2021AEUHAZ FTC-AEU-HAZ
Active
Jan 31, 2019Facades FISPNRF
FAILED TO FILE FISP CYCLE 8B TECHNICAL REPORT BY 02/21/2018
Active
Jan 26, 2018Elevators ACC1
Active
Jan 26, 2018Elevators ACC1
Active
Jan 3, 2017Elevators ACC1
Active
Jan 3, 2017Elevators ACC1
Active
Mar 31, 2014Elevators EVCAT1
Active
Mar 31, 2014Elevators EVCAT1
Active
Dec 13, 2011Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2010 INSPECTION REPORT
Active
Mar 19, 2003Boiler LL6291
Active
Sep 16, 1997Boiler LL6291
Active
Feb 10, 1997Boiler LL6291
Active
HPD (1) · C 0 · B 1 · A 0
IssuedClassViolationCorrect by
Jun 18, 2025BApt 8B · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE MECHANICAL VENTILATION SYSTEM WEST WALL IN THE BATHROOM LOCATED AT APT 8B, 8th STORY, 3rd APARTMENT FROM WEST AT NORTHJul 23, 2025

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 27, 2026, 4:01 PM ET. BBL 1015270028.