5 floors · 133,344 sq ft · built 2014 · class W1 · owner of record: Nyc Department Of Education
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 9 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 43 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 43 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 133,344 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 164 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 164 days | Annual filing |
| Energy audit and retro-commissioning (2034) Likely applies Local Law 87 · Calendar year 2034 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 3864). Agency page | Dec 31, 2034 in 2965 days | Next due 2034 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| May 11, 2026 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.ILLUMINATION FOREXITS,EXIT DISCHARGES AND PUBLIC CORRIDORS PER BC 1006.1;27-381.NOTED:EMERGENCY ILLUMINATED DISCHARGE LIGHTS AND EXIT SIGNS NOT OPERATING WH #35733078X | May 29, 2026 POP/IN-VIO | $0 |
| May 11, 2026 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NOTED:FIRE RATEDCLASSROOMS AND SMOKE DOORS NOT SELF-CLOSING PROPERLY DUE TO BINDING,MISSING AND OR FAULTY HARDWARE ON CLASSROOMS,225,B246 AND SMOKE DOORS AT #35733079H | May 29, 2026 POP/IN-VIO | $0 |
| May 11, 2026 | Construction CLASS - 2 REISSUE ON ECB#35721068Y FAILURE TO MAINTAIN BUILDING WALLS OR APPURTENANCES.NOTED:SPALLING AND MISSING CHUNKS OF CONCRETE AND AREAS SEPARATING AT SEVERAL AREAS AT FRONT MAINTENANCE OF WALKWAY ON FENCE CONCRETE #35733075K | May 29, 2026 POP/IN-VIO | $0 |
| May 11, 2026 | Construction CLASS - 2 REISSUE ON ECB#35721067M FAILURE TO MANTAIN BUILDING IN CODE-COMPLIANTMANNER.NOTED:MISSING HANDRAIL ON STAIRCASE BETWEEN 1ST FLOOR TO CELLARLEVEL AT STAIR A OBSERVED UPON INSPECTION.REM:REPAIR AND/OR REPLACE. #35733076M | May 29, 2026 POP/IN-VIO | $0 |
| May 11, 2026 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER,USE OF PROHIBITED DOOR AND/OR HARDWARE PER BC 1008.1.8;27-371(J).NOTED:THE INSTALLATION OF ILLEGAL DOOR KICK STOPS ON CLASSROOMS AND OR SMOKE DOORS AT SEVER #35733080P | May 29, 2026 POP/IN-VIO | $0 |
| May 11, 2026 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NOTED:STORAGE INBASEMENT ELECTRICAL SWITCH GEAR ROOM WITH NUMEROUS ITEMS CONTAINING FILE CABINETS,CLEANING EQUIPMENT AND PIECES OF STEEL AND SCAFFOLDING EQU #35733077Y | May 29, 2026 POP/IN-VIO | $0 |
| Jul 25, 2025 | Construction CLASS - 2 REISSUE#35685035M DATE OF ISSUE:09.23.2025 FAILURE TO MAINTAIN BUILDING WALL(S)OR APPURTENANCES AT THE TIME OF INSPECTION OBSERVED AND NOTEDMAIN ENTRANCE WALKWAY FENCE FOOTING CONCRETE WALLS ARE IN DISREPAIR CR #35721068Y | Sep 5, 2025 POP/IN-VIO | $0 |
| Jul 25, 2025 | Construction CLASS - 2 REISSUE#35685036Y DATE OF ISSUE:09.23.2024 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.AT THE TIME OF INSPECTION OBSERVED AND NOTED AT STAIR A BETWEEN 1ST AND CELLAR FLOORS HANDRAIL MISSING.REM:REPAIR #35721067M | Sep 5, 2025 POP/IN-VIO | $0 |
| Sep 23, 2024 | Construction CLASS - 2 REISSUE#35676103K OBSERVED MAIN ENTRANCE WALKWAY FENCE FOOTING CONCRETE WALLS ARE IN DISREPAIR CRACKS AND MISSING CONCRETE.REM:MAINTAIN EXTERIOR BUILDING WALL. #35685035M | Nov 29, 2024 POP/IN-VIO | $0 |
| Sep 23, 2024 | Construction CLASS - 2 REISSUE#35676102Z OBSERVED AT STAIR A BETWEEN 1ST AND CELLAR FLOORS HANDRAIL MISSING.REM:REPAIR AND/OR REPLACE. #35685036Y | Nov 29, 2024 POP/IN-VIO | $0 |
| May 23, 2023 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NOTE:OBSERVED ATSTAIRCASE A BETWEEN 1ST FLOOR & CELLAR LEVEL,HANDRAIL ON THE RIGHT HAND SIDE WHEN HEADING TOWARDS CELLAR IS NOT PROVIDED.REM:REPAIR AND/OR R #35676102Z | Sep 1, 2023 POP/IN-VIO | $0 |
| May 23, 2023 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING WALL(S)OR APPURTENANCES.NOTE:OBSERVED AT EXP.1,PRIVATE WALKWAY TO & FROM THE SCHOOL MAIN ENTRANCE HAS IRON FENCE APPROX.4FT(H) AND THE CONCRETE SUPPORTING THE FENCE IS IN DISREPAIR #35676103K | Sep 1, 2023 POP/IN-VIO | $0 |
| Jul 8, 2022 | Construction CLASS - 2 REISSUE#35586601Y FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER:OBSERVED:AT 5TH FL;90% OF THE DOORS DO NOT CLOSE PROPERLY,AT 4TH FL,RM 420 DOOR AT 1ST FL ROOM#136,138,120 DOORS DO NOT CLOSE PROPERLY WHE #35665204X | Sep 30, 2022 POP/IN-VIO | $0 |
| Issued | Violation | Status |
|---|---|---|
| Oct 1, 2019 | RETAINING WALL FAILED TO FILE CYCLE 1 TECHNICAL REPORT BY 12/31/2018 PER RCNY 103-09 #00497 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Oct 31, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle C (premises is in Community District 9) | Active |
| Oct 31, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle C (premises is in Community District 9) | Active |
| Apr 23, 2025 | Retaining Walls | Active |
| Oct 1, 2019 | Retaining Walls FTF-RW-INITL | Active |
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 18, 2026, 11:39 PM ET. BBL 2038640012.