6 floors · 30,020 sq ft · built 2000 · class O5 · owner of record: 155 Water St Associates
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 63 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 30,020 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 184 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 184 days | Annual filing |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 2 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1159 days | Next cycle year 2029 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Aug 25, 2004 | Construction Non-Hazardous WORK WITHOUT A PERMIT. WORK NOTED: CHIMNEY BEING DEMOLITED WORKER REMOVING BRICK FROM CHIMNEY AT ROOF LEVEL NO PERMIT POSTED AT TIME OF INSPREMEDY: STOP ALL WORK!! OBTAIN PERMIT OR RESTORE TO PRIOR LEGAL CONDIT #34450457J | Feb 28, 2005 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| Sep 26, 2022 | CONSTRUCTION FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. BLDG HAS A DEFECTIVE MASONRY FACADE. AS NOW IN PROVIOUS VIOLATION ISSUED ON 5/12/22 WHICH INCLUDE DAMAGED PARAPET WALLS, DAMAGED MASONRY ON CHIMNEY, DAMAGED WINDOW SILLS THROUGHOUT. REMEDY: COMPLY WITH CODE #LL0203JC | DOB VIOLATION - ACTIVE |
| Dec 10, 2021 | CONSTRUCTION EMERGENCY WORK ORDER DUE TO UNSTABLE CHIMNEY LOCATED AT EXP 1 NORTHEAST CORNER. REMEDY: IMMED PROVIDE SAFETY MEASURES FROM UNSTABLE CHIMNEY AND DEFECTIVE BRICKWORK AT ALL EXPOSURES UNDER NYS LIC PROF ENG'R DIRECTION. ALSO RETAIN ENG'R TO PROVIDE A PLAN FOR REPAIRS TO BE MADE TO THE FACADE AND CHIMNE #LLFA01LJN | DOB VIOLATION - ACTIVE |
| Dec 10, 2021 | CONSTRUCTION EMERGENCY WORK ORDER DUE TO UNSTABLE CHIMNEY LOCATED AT EXP 1, NORTH EAST CORNER. REMEDY: IMMED PROVIDE SAFETY MEASURES FROM UNSTABLE CHIMNEY AND DEFECTIVE BRICKWORK AT ALL EXPOSURES UNDER NYS LIC PROF ENGINEER'S DIRECTION. ALSO RETAIN ENGINEER TO PROVIDE A PLAN FOR REPAIRS TO BE MADE TO THE FACADES #LLFA01LJ | DOB VIOLATION - ACTIVE |
| Dec 1, 2021 | FAILURE TO POST ENERGY GRADE/SCORE FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3 #2102057 | DOB VIOLATION - ACTIVE |
| Apr 23, 2019 | CONSTRUCTION FTM BUILDING EXTERIOR WALLS/FACADES AND APPURTANCES.EXP#1 WEST ELEV: STEP CRACK AT GROUND LEVE. EXP#3,EAST ELEVATION:WOOD WINDOW SILL CRACKED,HANGING FLASHING OVER SILL.EXP#4 SOUTH ELEVATION:SPALLING WINDOW SILLS ERODED MORTAR JOINTS.ROOF:SPALLED AND MISSING COPING REMEDY:MAINTAIN BLDG EXTERIOR WALL #LL0208PR | DOB VIOLATION - ACTIVE |
| Apr 23, 2019 | CONSTRUCTION FTM BUILDING EXTERIOR WALLS/FACADES AND APPURTENANCES. EXP#1 WEST ELEVATION:STEP CRACK AT GROUND LEVEL.EXP#3 EAST ELEVATION:WOOD WINDOW SILL CRACKED,HANGING FLASHING OVER SILL.EXP#4 SOUTH ELEVATION:SPALLING WINDOW SILLS ERODED MORTAR JOINTS. ROOF: SPALLED AND MISSING COPING REMEDY:MAINTAIN BLDG EXTE #LL0207PR | DOB VIOLATION - ACTIVE |
| May 1, 2001 | CONSTRUCTION #02EC05 | DOB VIOLATION - ACTIVE |
| May 1, 2001 | CONSTRUCTION WORK WITHOUT A PERMIT. WORK NOTED: IN CELLAR A SHOWER & TOILET WAS INSTALLED ON A LOFT TYPE STRUCTURE & DEPT OF BLDGS RECORDS INDICATES NO PERMITS WERE ISSUED REMEDY: OBTAIN PERMIT, OR RESTORE TO PRIOR LEGAL CONDITION #02EC02 | VIOLATION WORK WITHOUT PERMIT - ACTIVE |
| Jan 13, 1997 | LOCAL LAW 10/81 - ELEVATOR #02390 | DOB VIOLATION - ACTIVE |
| Aug 16, 1993 | LOCAL LAW 62/91 - BOILERS #18947 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Dec 1, 2021 | Energy Grade - LL33 FTP-EN-EGRDEA | Active |
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)