Manhattan · Block 350 · Lot 37 · 10002

154 Stanton Street

2 floors · 1 apartments · 3,600 sq ft · built 1920 · class K4 · owner of record: Y&K 155 Llc

26open violations
$26,180ECB/OATH penalties owed
1HPD class C (immediately hazardous)
68dto Annual boiler inspection (1 boiler)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 68 days
Keep the report on file (not filed with DOB)
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2024-10-04 (Accepted). Agency page

Dec 31, 2026
in 68 days
1 of 1 without an accepted 2026 report yet
Annual property registration Check
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 312 days
Required only if the owner doesn't live there
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 3 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 799 days
Next cycle year 2028

Open violations

ECB / OATH (8) · $26,180 owed
IssuedViolationHearingBalance
Aug 6, 2026Construction CLASS - 2
GENERAL CONTRACTOR FAILED TO FILE CERTIFICATE OF CORRECTION WITH THE DOB. NO CORRECTIVE MEASURES ON RECORD FOR VIOLATION# 039555236Z, ISSUED ON 6.08.2026. ..
#39557610Z
Oct 15, 2026
DEFAULT
$1,280
Jun 8, 2026Unknown CLASS - 2
AT THE TIME OF MY INSPECTION OBSERVED CS WASN'T PRESENT BUT COMPETENT WAS BUT THE SITE CONDITIONS 3301.13.7 CS FAILED TO ADDRESS, OPEN LEDGES WITHOUT INSTALLING GUARDRAIL SYSTEM,NO EGRESS/INGRESS ACCESS,ACTIVE
#39555234P
Nov 5, 2026
PENDING
$5,000
Jun 8, 2026Construction CLASS - 1
AT THE TIME OF MY INSPECTION OBSERVED ACTIVE SITE FAILED TO ADDRESS HOUSEKEEPING DUTIES WITH OVERLOADED DEBRIS OBSTRUCTING PATHWAYS FOR ACTIVE WORKERS, EMT RESPONDENTS, & INSPECTORS. BC 3303.4 & 27-1018 SITE MU
#39555235R
Dec 3, 2026
$2,500
Jun 8, 2026Construction CLASS - 1
AT THE TIME OF INSPECTION OBSERVED SITE WITHOUT DEMO NOTIFICATION UNDER PERMIT # M00978747 BC 3306.3& 27-195 .SITE FAILED TO ADDRESS NOR PROVIDE DEMOLITION NOTIFICATION FOR ACTIVELY COMMENCING ONGOING DEMO OPER
#39555236Z
Dec 3, 2026
PENDING
$2,500
Jun 8, 2026Unknown CLASS - 1
AT THE TIME OF MY INSPECTION OBSERVED SITE WITHOUT ANY GUARDRAIL SYSTEM INSTALLED THROUGHOUT ACTIVE SITE DURING DEMO/CONSTRUCTION OPERATIONS. SITE UNDER PERMIT # M00978747-I1 FAILED TO ADDRESS IMMEDIATE NEED FO
#39555233N
Dec 3, 2026
$5,000
Jun 8, 2026Unknown CLASS - 1
AT THE TIME OF MY INSPECTION OBSERVED SITE WITHOUT ANY IMMEDIATE INGRESS/EGRESS ACCESS FOR ACTIVE WORKERS, EMT RESPONDENTS, & INSPECTORS 3303.9 SITE MUST PROVIDE THESE SAFETY FACTORS ON ALL ACTIVE DEMO/CONSTRUC
#39555232L
Dec 3, 2026
$5,000
May 12, 2026Construction CLASS - 2
AT TIME OF INSPECTION, OBSERVED SIDEWALK SHED LIGHTING NOT ILLUMINATED AT EXPOSURES 1 AND 2 OF INACTIVE 4-STORY BUILDING LOCATED AT 154 STANTON STREET AND 162-164 SUFFOLK STREET, CONTRARY TO BC 3307.6.4.7. COND
#39554011N
Feb 4, 2027
$2,400
Jul 22, 2025Construction CLASS - 1
ATOI NO ACTIVE CONSTRUCTION IS IN PROGRESS. FENCE ERECTED IN THE PROPERTY IS CONTRARY TO THE APPROVED PLANS SUBMITTED TO THE DEPARTMENT. CONSTRUCTION ROLLING GATE IS IN A WRONG LOCATION., CONFORM WORK TO APPROV
#39154567X
Dec 7, 2026
$2,500
DOB (3)
IssuedViolationStatus
Nov 14, 2025LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
#01929
DOB VIOLATION - ACTIVE
Sep 23, 2024LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL LOW PRESSURE INSPECTION
#01981
DOB VIOLATION - ACTIVE
Feb 24, 2017LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2015 INSPECTION REPORT
#00855
DOB VIOLATION - ACTIVE
DOB NOW Safety (4)
IssuedViolationStatus
Jul 30, 2026AEUHAZ FTC-AEU-HAZ
Active
Nov 14, 2025Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
Active
Sep 23, 2024Boiler LBLVIO
Violation Issued-Failure To File 2023 External Low Pressure Inspection Report
Active
Feb 24, 2017Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2015 INSPECTION REPORT
Active
HPD (16) · C 1 · B 13 · A 2
IssuedClassViolationCorrect by
Feb 10, 2020BApt UNIT2 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT UNIT2, 2nd STORY, 1st APARTMENT FROM WEST AT NORTHMar 16, 2020
Feb 10, 2020CApt UNIT2 · § 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTER BALANCES AT LOWER SASH 2ND WINDOW FROM EAST IN THE 5th ROOM FROM NORTH AT WEST LOCATED AT APT UNIT2, 2nd STORY, 1st APARTMENT FROM WEST AT NORTHFeb 18, 2020
Feb 10, 2020AApt UNIT2 · § 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR EAST WALL IN THE 5th ROOM FROM NORTH AT EAST LOCATED AT APT UNIT2, 2nd STORY, 1st APARTMENT FROM WEST AT NORTHMay 15, 2020
Feb 10, 2020BApt UNIT2 · § 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES AT ELECTRICAL OUTLET AT EAST WALL IN THE 5th ROOM FROM NORTH AT EAST LOCATED AT APT UNIT2, 2nd STORY, 1st APARTMENT FROM WEST AT NORTHMar 16, 2020
Feb 10, 2020BApt UNIT2 · § 27-2005 ADMIN. CODE: PROPERLY SECURE THE LOOSE ELECTRICAL OUTLET AT EAST WALL IN THE 5th ROOM FROM NORTH AT EAST LOCATED AT APT UNIT2, 2nd STORY, 1st APARTMENT FROM WEST AT NORTHMar 16, 2020
Feb 10, 2020BApt UNIT2 · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN CLOSET AT EAST IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT UNIT2, 2nd STORY, 1st APARTMENT FROM WEST AT NORTHMar 16, 2020
Feb 10, 2020BApt UNIT2 · § 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR THE CEILING IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT UNIT2, 2nd STORY, 1st APARTMENT FROM WEST AT NORTHMar 16, 2020
Feb 10, 2020BApt UNIT2 · § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELECTRICAL WIRES AT EAST WALL IN CLOSET IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT UNIT2, 2nd STORY, 1st APARTMENT FROM WEST AT NORTHMar 16, 2020
Feb 10, 2020BApt UNIT2 · § 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTER BALANCES AT LOWER SASH AT WINDOW IN THE BATHROOM LOCATED AT APT UNIT2, 2nd STORY, 1st APARTMENT FROM WEST AT NORTHMar 16, 2020
Feb 10, 2020BApt UNIT2 · § 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTER BALANCES AT LOWER SASH AT WINDOW AT WEST WALL IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT UNIT2, 2nd STORY, 1st APARTMENT FROM WEST AT NORTHMar 16, 2020
Feb 10, 2020AApt UNIT2 · § 27-2005 ADMIN. CODE: REFIT UPPER AND LOWER SASH AT WINDOW AT WEST WALL IN THE 4th ROOM FROM NORTH AT WEST LOCATED AT APT UNIT2, 2nd STORY, 1st APARTMENT FROM WEST AT NORTHMay 15, 2020
Feb 10, 2020BApt UNIT2 · § 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE CEILING LIGHT FIXTURE IN THE 4th ROOM FROM NORTH AT WEST LOCATED AT APT UNIT2, 2nd STORY, 1st APARTMENT FROM WEST AT NORTHMar 16, 2020
Feb 10, 2020BApt UNIT2 · § 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTER BALANCES AT LOWER SASH AT 1ST WINDOW FROM EAST IN THE 5th ROOM FROM NORTH AT CENTER LOCATED AT APT UNIT2, 2nd STORY, 1st APARTMENT FROM WEST AT NORTHMar 16, 2020
Feb 10, 2020BApt UNIT2 · § 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRICAL OUTLET AT CENTER OF FLOOR IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT UNIT2, 2nd STORY, 1st APARTMENT FROM WEST AT NORTHMar 16, 2020
Feb 10, 2020BApt UNIT2 · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT UNIT2, 2nd STORY, 1st APARTMENT FROM WEST AT NORTHMar 16, 2020
Feb 10, 2020BApt UNIT2 · § 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE CEILING LIGHT FIXTURE IN THE BATHROOM LOCATED AT APT UNIT2, 2nd STORY, 1st APARTMENT FROM WEST AT NORTHMar 16, 2020

Issued in the last 120 days

DateSourceWhatNow
Aug 6, 2026ECBConstruction: GENERAL CONTRACTOR FAILED TO FILE CERTIFICATE OF CORRECTION WITH THE DOB. NO CORRECTIVE MEASURES ON RECORD FOR VIOLATION# 039555236Z, ISSUED ON 6.08.2026. ..Open
Jul 30, 2026DOB SafetyAEUHAZ: Open

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 24, 2026, 9:55 AM ET. BBL 1003500037.