7 floors · 41,582 sq ft · built 2017 · class H3 · owner of record: 154 Bruckner Blvd Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 66 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 41,582 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 187 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 187 days | Annual filing |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 797 days | Next cycle year 2028 |
| Facade inspection report (Cycle 10A) Applies Local Law 11 / FISP · Feb 21, 2025 to Feb 21, 2027 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 4, 5, 6 or 9 are in sub-cycle 10A. Agency page | On file | Cycle 10 filing on record: SAFE (2026-04-15) |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Aug 19, 2026 | Elevators CLASS - 1 CLASS 1 RTS: 1. UPON FIREFIGHTER'S SERVICE PHASE I INSPECTION, DEVICE FAILED TO RETURN TO NORMAL MODE, INDICATING IMPROPER CONTROL RESPONSE. AS PER ASME A17.1 2.27 AND 8.6. REMEDY: RESTORE PROPER PHASE I FUNCTI #39201113K | Oct 30, 2026 PENDING | $1,250 |
| Aug 11, 2025 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: NO FIRE STOPPING PER BC 712.3 (2014 CODE); 27-345; BC 711.2.4 (2022 CODE. OBSERVED OPENINGS ADJACENT TO DOORS THROUGHOUT BASEMENT. IMPROPER FIRE STOPPING, #39156644J | Sep 3, 2026 IN VIOLATION | $625 |
| Aug 11, 2025 | Construction CLASS - 1 UNSAFE STORAGE OF COMBUSTIBLE MATERIAL AND EQUIPMENT. OBSERVED WASHING MACHINE STORED IN ELEVATOR ROOM. LOCATED BASEMENT LEVEL. POTENTIAL FIRE HAZARD., MAINTAIN STORAGE IN COMPLIANCE WITH FIRE CODE #39156643H | Sep 3, 2026 IN VIOLATION | $2,500 |
| Oct 23, 2024 | Elevators CLASS - 1 RESPONDING, TO A 311 ELEVATOR COMPLAINT, UPON INSPECTION, THE CAR IS FOUND OUT-OF-SERVICE, BY THE WAY OF CEASE USE NOT LIFTED, CLASS 1 VIOLATION ISSUED FOR, CEASE USE RECURRING CONDITION ON CEASE USE, REMEDY; R #39128321R | Feb 16, 2027 DEFAULT | $3,125 |
| Aug 13, 2024 | Elevators CLASS - 1 MAIN BRAKE DEFECTIVE. NEED TO CORRECT. SCHEDULE FOR A REINSPECTION TO PERFORM A LOAD TEST WITH 125% IN THE PRESENCE OF A D.O.B. INSPECTOR. CLASS 2 ITEMS: BRAKE MAINTENANCE TAG EXPIRED. PROVIDE AN UPDATED MAINTE #39121690K | Feb 16, 2027 DEFAULT | $3,125 |
None open.
None open.
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Aug 19, 2026 | ECB | Elevators: CLASS 2: 1. EMERGENCY PHONE INOPERATIVE AND FAILING TO PROVIDE REQUIRED TWO-WAY COMMUNICATION. AS PER ASME A17.1 2.27. REMEDY: REPAIR EMERGENCY PHONE AND VERIFY RELIABLE COMMUNICATION. 2. EMERGENCY LIGHT TEST S | Closed |
| Aug 19, 2026 | ECB | Elevators: CLASS 1 RTS: 1. UPON FIREFIGHTER'S SERVICE PHASE I INSPECTION, DEVICE FAILED TO RETURN TO NORMAL MODE, INDICATING IMPROPER CONTROL RESPONSE. AS PER ASME A17.1 2.27 AND 8.6. REMEDY: RESTORE PROPER PHASE I FUNCTI | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 26, 2026, 9:28 PM ET. BBL 2025460011.