Queens · Block 4548 · Lot 58 · 11357

154-50 12 Avenue

2 floors · 2 apartments · 1,394 sq ft · built 1920 · class B3 · owner of record: Frances Casabianca

7open violations
$26,250ECB/OATH penalties owed
0HPD class C (immediately hazardous)
303dto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Check
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 303 days
Required only if the owner doesn't live there

Open violations

ECB / OATH (5) · $26,250 owed
IssuedViolationHearingBalance
Oct 23, 2026Construction CLASS - 1
OBSERVED IN THE BACK OF THE BUILDING AT 2ND FLOOR, UNPERMITTED UNPLANNED AN UNDOCUMENTED VERTICAL AND HORIZONTAL EXTENSION APPROXIMATELY 16' X 21'. NO PERMIT FOR THIS EXTENSION AT THE TIME OF INSPECTION. JOB IS
#39209213Y
Dec 29, 2026
PENDING
$2,500
Oct 23, 2026Construction CLASS - 1
ATOI OBSERVED ACTIVE CONSTRUCTION OF A VERTICAL AND HORIZONTAL EXTENSION WITH NO SAFETY MEASURES IN PLACE, MISSING GUARDRAILS, NO CONSTRUCTION FENCE BC 3307.7, NO OVERHEAD PROTECTION WHICH RESULTED IN VACATING
#39209214X
Dec 29, 2026
PENDING
$10,000
Oct 23, 2026Construction CLASS - 1
ATOI OBSERVED ACTIVE CONSTRUCTION OF A VERTICAL AND HORIZONTAL EXTENSION WITH NO SAFETY MEASURES IN PLACE, MISSING GUARDRAILS, NO CONSTRUCTION FENCE BC 3307.7, NO OVERHEAD PROTECTION WHICH RESULTED IN VACATING
#39209245Z
Dec 29, 2026
PENDING
$10,000
Oct 23, 2026Unknown CLASS - 1
OBSERVED, ON THE 2ND FLOOR NEW ELECTRICAL WORK DONE. INSTALLED SWITCHES, OUTLETS, CIRCUIT BREAKERS AND ELECTRICAL FIXTURES THROUGHOUT THE SECOND FLOOR. NO ELECTRICAL PERMIT FOR THIS WORK AT THE TIME OF INSPECTI
#39209215H
Dec 29, 2026
PENDING
$2,500
Oct 23, 2026Construction CLASS - 2
OBSERVED ON THE 2ND FLOOR IN THE NEW BATHROOM, NEW PLUMBING WORK WAS DONE. INSTALLED NEW PLUMBING PIPING FOR HOT AND COLD-WATER LINES AND PVC PIPING FOR DRAINAGE. NO PLUMBING PERMIT FOR THIS WORK AT THE TIME OF
#39209216J
Dec 29, 2026
PENDING
$1,250
DOB (2)
IssuedViolationStatus
Oct 26, 2026IMMEDIATE EMERGENCY
REMEDY:INSTALL APPX 110 TOTAL LINEAR FT OF CONSTRUCTION FENCE
#20672
DOB VIOLATION - ACTIVE
Oct 23, 2026CONSTRUCTION
OBSERVED IN THE BACK OF THE BUILDING AT 2ND FLOOR, UNPERMITTED UNPLANNED AN UNDOCUMENTED VERTICAL AND HORIZONTAL EXTENSION APPROXIMATELY 16' X 21'. NO PERMIT FOR THIS EXTENSION AT THE TIME OF INSPECTION.
#26-02447
DOB VIOLATION - ACTIVE
DOB NOW Safety (0)

None open.

HPD (0)

None open.

Issued in the last 120 days

DateSourceWhatNow
Oct 26, 2026DOBIMMEDIATE EMERGENCY: REMEDY:INSTALL APPX 110 TOTAL LINEAR FT OF CONSTRUCTION FENCEOpen
Oct 23, 2026DOBCONSTRUCTION: OBSERVED IN THE BACK OF THE BUILDING AT 2ND FLOOR, UNPERMITTED UNPLANNED AN UNDOCUMENTED VERTICAL AND HORIZONTAL EXTENSION APPROXIMATELY 16' X 21'. NO PERMIT FOR THIS EXTENSION AT THE TIME OF INSPECTION.Open
Oct 23, 2026ECBConstruction: OBSERVED IN THE BACK OF THE BUILDING AT 2ND FLOOR, UNPERMITTED UNPLANNED AN UNDOCUMENTED VERTICAL AND HORIZONTAL EXTENSION APPROXIMATELY 16' X 21'. NO PERMIT FOR THIS EXTENSION AT THE TIME OF INSPECTION. JOB ISOpen
Oct 23, 2026ECBConstruction: ATOI OBSERVED ACTIVE CONSTRUCTION OF A VERTICAL AND HORIZONTAL EXTENSION WITH NO SAFETY MEASURES IN PLACE, MISSING GUARDRAILS, NO CONSTRUCTION FENCE BC 3307.7, NO OVERHEAD PROTECTION WHICH RESULTED IN VACATINGOpen
Oct 23, 2026ECBConstruction: ATOI OBSERVED ACTIVE CONSTRUCTION OF A VERTICAL AND HORIZONTAL EXTENSION WITH NO SAFETY MEASURES IN PLACE, MISSING GUARDRAILS, NO CONSTRUCTION FENCE BC 3307.7, NO OVERHEAD PROTECTION WHICH RESULTED IN VACATINGOpen
Oct 23, 2026ECBUnknown: OBSERVED, ON THE 2ND FLOOR NEW ELECTRICAL WORK DONE. INSTALLED SWITCHES, OUTLETS, CIRCUIT BREAKERS AND ELECTRICAL FIXTURES THROUGHOUT THE SECOND FLOOR. NO ELECTRICAL PERMIT FOR THIS WORK AT THE TIME OF INSPECTIOpen
Oct 23, 2026ECBConstruction: OBSERVED ON THE 2ND FLOOR IN THE NEW BATHROOM, NEW PLUMBING WORK WAS DONE. INSTALLED NEW PLUMBING PIPING FOR HOT AND COLD-WATER LINES AND PVC PIPING FOR DRAINAGE. NO PLUMBING PERMIT FOR THIS WORK AT THE TIME OFOpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 2, 2026, 8:21 PM ET. BBL 4045480058.