3 floors · 40,734 sq ft · built 1966 · class H4 · owner of record: Royal York Equitiescorp
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 43 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 40,734 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 164 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 164 days | Annual filing |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 13 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1139 days | Next cycle year 2029 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Sep 21, 2026 | Construction CLASS - 1 ATOI OBSERVED A BROKEN/DISCONNECTED FLUE PIPE FOR THE LAUNDRY DRIER EXHAUST. CONTRARY TO MC 504.4 - EXHAUST INSTALLATION: DRYER EXHAUST DUCTS ARE REQUIRED TO TERMINATE ON THE EXTERIOR OF THE BUILDING., REPAIR A #39204866Z | Dec 1, 2026 PENDING | $2,500 |
| Sep 21, 2026 | Construction CLASS - 1 AT THE TIME TIME OF INSPECTION OBSERVED UNAPPROVED MATERIAL USED FOR CLOTHS DRIER EXHAUST. CONTRARY TO MC 504.6 - EXHAUST DUCT CONSTRUCTION: DRYER EXHAUST DUCTS SHALL BE CONSTRUCTED OF APPROVED MATERIALS AND IN #39204867K | Dec 1, 2026 PENDING | $2,500 |
| Sep 21, 2026 | Construction CLASS - 1 ATOI OBSERVED PVC BEING USED FOR DRAINAGE THROUGH OUT THE BASEMENT AND DISCHARGING FROM THE SUMP PUMP. CONTRARY TO . PLUMBING CODE 702.1 - ABOVE-GROUND SANITARY DRAINAGE AND VENT PIPE: DRAINAGE AND VENT PIPING #39204865R | Dec 1, 2026 PENDING | $2,500 |
| Feb 17, 2026 | Construction CLASS - 2 FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS FOR SUMMONS 39128988P., FILE A CERTIFICATE OF CORRECTION #39177404N | Oct 13, 2026 IN VIOLATION | $1,250 |
| Feb 17, 2026 | Unknown CLASS - 1 UNAPPROVED/UNSAFE/UNSUITABLE ELECTRICAL EQUIPMENT, APPARATUS, MATERIALS, DEVICES, APPLIANCES OR WIRING IN USE FOR SUMMONS 39128987N. OBSERVED THE USE OF FLEXIBLE CORDS AS PERMANENT WIRING AT PARKING LOT, GAS ME #39177403L | Oct 13, 2026 DEFAULT | $4,030 |
| Feb 17, 2026 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: NO FIRE STOPPING PER BC 712.3 (2014 CODE); 27-345; BC 711.2.4 (2022 CODE) FOR SUMMONS 39128982Y. OBSERVED NO FIRE-STOPPING AT ALL HOLE PENETRATIONS THROUGH #39177400X | Oct 13, 2026 DEFAULT | $6,280 |
| Feb 17, 2026 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: USE OF PROHIBITED DOOR AND/OR HARDWARE PER BC 1008.1.8 (2014 CODE); 27-371; BC 1008.1.9 (2014 CODE); BC 1010.1.8 (2022 CODE); BC 1010.1.9 (2022 CODE) FOR S #39177401H | Oct 13, 2026 DEFAULT | $6,280 |
| Feb 17, 2026 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER FOR SUMMONS 39128994L. OBSERVED RESIDENTIAL GAS FLEX ON COMMERCIAL LAUNDRY EQUIPMENT (6 DRYERS)., REPAIR AND/REPLACE #39177402J | Oct 13, 2026 DEFAULT | $6,280 |
| Feb 17, 2026 | Construction CLASS - 2 FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS FOR SUMMONS 39128985J., FILE A CERTIFICATE OF CORRECTION #39177399H | Oct 13, 2026 IN VIOLATION | $1,250 |
| Nov 10, 2025 | Construction CLASS - 2 OBSERVED IN BASEMENT FERNCO COUPLINGS AND PVC WASTE LINES. IN BOILER ROOM INSTALLED SPRINKLER HEAD BACKWARDS AND USING UNIONS ON GAS LINES. IN LAUNDRY ROOM USING BUSHING AND LACK SUPPORT ON GAS LINE. ON FIRST F #39166529N | Jan 7, 2027 DEFAULT | $6,250 |
| Nov 10, 2025 | Construction CLASS - 1 FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY. OBSERVED SECURITY DESK AND CHAIR OBSTRUCTING PASSAGEWAY. LOCATE IN MAIN LOBBY AREA. POTENTIAL FIRE HAZARD., REMOVE OBSTRUCTION #39166781P | Jan 7, 2027 DEFAULT | $6,250 |
| Nov 10, 2025 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. OBSERVED EXCESSIVE STORAGE IN BOILER ROOM. (BICYCLE, RADIO, TOOL BOX, BOXES) POTENTIAL FIRE HAZARD., REPAIR AND/REPLACE #39166782R | Jan 7, 2027 DEFAULT | $12,500 |
| Oct 30, 2024 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: NO FIRE STOPPING PER BC 712.3 (2014 CODE); 27-345; BC 711.2.4 (2022 CODE. OBSERVED HOLE PENETRAIONS THROUGHOUT BUILDING. INCASE OF EMERGENCY THIS CREATES F #39128982Y | Jan 7, 2025 DEFAULT | $12,500 |
| Oct 30, 2024 | Construction CLASS - 2 EXIT DOOR NOT SELF-CLOSING. OBSERVED NON SELF CLOSING AT UTILITY AND MECHINAL ROOMS THROUGHOUT BUILDING. IN CASE OF EMERGENCY THIS CAN CAUSE A FIRE OR HAZARDOUS SMOKE CONDITION, REPAIR/REPLACE DOOR #39128984H | Jan 7, 2025 DEFAULT | $3,125 |
| Oct 30, 2024 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: USE OF PROHIBITED DOOR AND/OR HARDWARE PER BC 1008.1 (2014 CODE); 27-371; BC 1008.1.9 (2014 CODE); BC 1010.1.8 (2022 CODE); BC 1010.1.9 (2022 CODE). OBSERV #39128983X | Jan 7, 2025 DEFAULT | $6,250 |
| Oct 30, 2024 | Construction CLASS - 2 OBSERVED IN EXCESSIVE COMBUSTIBLE STORAGE IN THE BOILER ROOM AND ALSO IN THE GAS METER ROOM LOCATED ON THE FIRST FLOOR. AS PER E 3 OF THE FUEL GAS CODE, GAS METER ROOMS, WHEN PROVIDED, SHALL AT ALL TIMES BE KEP #39128995N | Jan 7, 2025 DEFAULT | $3,125 |
| Oct 30, 2024 | Construction CLASS - 2 OBSERVED NO VENTILATION IN THE GAS METER ROOM. AS PER E 4 OF THE FUEL AS CODE GAS METER ROOMS SHALL BE PROPERLY VENTED., REPAIR AND/OR REPLACE #39128992H | Jan 7, 2025 DEFAULT | $3,125 |
| Oct 30, 2024 | Construction CLASS - 2 OBSERVED NEWLY INSTALLED 4 INCH AND 2 INCH PVC PIPING IN GAS METER ROOM LOCATED ON THE FIRST FLOOR. NO PERMITS ON FILE AT THE DOB FOR THIS APPLICATION., OBTAIN ALL PERMITS #39128993J | Mar 31, 2026 IN VIOLATION | $1,250 |
| Oct 30, 2024 | Unknown CLASS - 1 I OBSERVED IN THE GAS METER ROOM, THE LAUNDRY ROOM, THE BOILER ROOM AND THE EXTERIOR PARKING LOT, THE USE OF FLEXIBLE CORDS AS PERMANENT WIRING. EC 400.8 PROHIBITS THIS. ALSO NOTED THE FAILURE TO SUPPORT BOXES #39128987N | Jan 7, 2025 DEFAULT | $8,000 |
| Oct 30, 2024 | Unknown CLASS - 1 I OBSERVED THE GROUND CONDUCTOR AND CLAMP NOT SECURELY ATTACHED TO THE WATER MAIN TO PROVIDE GROUND PROTECTION FOR THE MAIN ELECTRICAL SERVICE. PHOTOS TAKEN., PROPERLY INSTALL GROUND ELECTRODE CONDUCTOR; PROPER #39128988P | Jan 7, 2025 DEFAULT | $24,000 |
| Oct 30, 2024 | Unknown CLASS - 2 I OBSERVED ON THE ROOF, THE 2ND FLOOR PANTRY,AND STAFF BATHROOM, THE EXTERIOR FRONT AND BACK THE USE OF CONVENIENCE OUTLETS NOT OF THE GFCI TYPE NOR PROTECTED AS REQUIRED FOR OUTSIDE OUTLETS AND WITHIN 6 FT OF #39128986L | Jan 7, 2025 DEFAULT | $10,000 |
| Oct 30, 2024 | Construction CLASS - 1 OBSERVED RESIDENTIAL GAS FLEX ON COMMERCIAL LAUNDRY EQUIPMENT ( 3 DRYERS). AS PER CHAPTER 411 OF THE FUEL GAS CODE COMMERCIAL APPLIANCES SHALL BE INSTALLED WITH RIGID PIPING., REPAIR AND/REPLACE #39128994L | Jan 7, 2025 DEFAULT | $6,250 |
| Oct 30, 2024 | Construction CLASS - 1 FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY. OBSERVED AC UNIT INSTALL INTO A ROOM BY PASSAGEWAY AT STAIRCASE, LOCATED ON 3 FLOOR. IN CASE AN EMERGENCY TRIPPING HAZARD WILL OCCUR., REMOVE OBSTRUCTION #39128985J | Jan 7, 2025 DEFAULT | $6,250 |
| Issued | Violation | Status |
|---|---|---|
| Dec 1, 2024 | FAILURE TO POST ENERGY GRADE/SCORE FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3 #2401828 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Dec 1, 2024 | Energy Grade - LL33 FTP-EN-EGRDEA | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Jul 18, 2025 | C | § 27-2056.7 ADM CODE: CORRECT FAILURE TO PROVIDE TO THE DEPARTMENT WITHIN 45 DAYS OF DEMAND ALL RECORDS REQUIRED TO BE MAINTAINED BY OWNER PURSUANT TO LOCAL LAW 1 OF 2004 RELATED TO LEAD-BASED PAINT NOTICES, INSPECTIONS AND REMEDIATION/ABATEMENT ACTIVITIES. | Jul 22, 2025 |
| Date | Source | What | Now |
|---|---|---|---|
| Sep 21, 2026 | ECB | Construction: ATOI OBSERVED A BROKEN/DISCONNECTED FLUE PIPE FOR THE LAUNDRY DRIER EXHAUST. CONTRARY TO MC 504.4 - EXHAUST INSTALLATION: DRYER EXHAUST DUCTS ARE REQUIRED TO TERMINATE ON THE EXTERIOR OF THE BUILDING., REPAIR A | Open |
| Sep 21, 2026 | ECB | Construction: AT THE TIME TIME OF INSPECTION OBSERVED UNAPPROVED MATERIAL USED FOR CLOTHS DRIER EXHAUST. CONTRARY TO MC 504.6 - EXHAUST DUCT CONSTRUCTION: DRYER EXHAUST DUCTS SHALL BE CONSTRUCTED OF APPROVED MATERIALS AND IN | Open |
| Sep 21, 2026 | ECB | Construction: ATOI OBSERVED PVC BEING USED FOR DRAINAGE THROUGH OUT THE BASEMENT AND DISCHARGING FROM THE SUMP PUMP. CONTRARY TO . PLUMBING CODE 702.1 - ABOVE-GROUND SANITARY DRAINAGE AND VENT PIPE: DRAINAGE AND VENT PIPING | Open |