2 floors · 2 apartments · 1,600 sq ft · built 1915 · class B3 · owner of record: Lakeview Loan Servicing, Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Check HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 288 days | Required only if the owner doesn't live there |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Oct 13, 2026 | Construction CLASS - 1 OBSERVED VERTICAL AND HORIZONT CARKS ON THE BUILDING AT ROOF LEVEL AND ON THE SIDE OF THE BUILDING NEXT TO EXPOSURE 2 SIDE., REPAIR AND/REPLACE #39207613Y | Dec 22, 2026 PENDING | $2,500 |
| Oct 28, 2021 | Construction CLASS - 2 OCCUPANCY CONTRARY TO THAT ALLOWED BY C/O OR BLDGS DEPT RECORDS.ILLEGAL RMS 2STY DISCONT ILLEGAL USAGE #35481655Z | May 17, 2022 DEFAULT | $6,250 |
| Mar 23, 2021 | Construction CLASS - 2 FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION #35329568Y ISSUED ON 05-01-18 AND TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28-201.1 AND 1RCNY 102-01. COMPLY WITH COMMISSIONE #35528453X | Jun 15, 2021 DEFAULT | $3,125 |
| Dec 18, 2020 | Construction CLASS - 2 FAILURE TO COMPLY W/ THE COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION#35329568Y ISSUED ON 5/1/18 & TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28-201.1 & 1RCNY102-01.OCCUPANCY CONTRARY TO THAT ALLOWE #35525363Z | Mar 9, 2021 DEFAULT | $3,125 |
| Oct 2, 2020 | Construction CLASS - 2 FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#35329568Y ISSUED ON 05/01/18 & TO FILE A CERT OF CORRECTION PURSUANT TO 28-201.1 & 1RCNY 102-01. FOR OCCUPANCY CONTRARY TO THAT ALLOWED BY THE C OF #35521220N | Dec 22, 2020 DEFAULT | $3,125 |
| Feb 27, 2020 | Construction CLASS - 2 FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#35329568Y ISSUED ON 05/01/18 & TO FILE A CERT OF CORRECTION PURSUANT TO 28-201.1 & 1RCNY 102-01. REMEDY: COMPLY W/COMM'S ORDER &/OR FILE A CERT OF C #35517411Y | Feb 23, 2021 DEFAULT | $3,125 |
| Nov 1, 2019 | Construction CLASS - 2 FAILURE TO COMPLY WITH THE COMMSSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION#35329568Y ISSUED ON 5/1/18 AND TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28-201.1 AND 1RCNY 102-01.DOB RECORDS INDICATE RESIDEN #35511687H | Jan 14, 2020 DEFAULT | $3,125 |
| Jul 13, 2019 | Construction CLASS - 2 FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION #35329568Y ISSUED ON 5/01/18 & TO FILE A CERT.OF CORRECTION PURSUANT TO 28-201.1 & 1RCNY 102-01.D.O.B'S RECORDS INDICATE RESIDENCE #35401127M | Sep 17, 2019 DEFAULT | $3,125 |
| May 9, 2019 | Construction CLASS - 2 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. USE OF PROHIBITED DOOR &/OR HARDWARE PER BC1008.1.8;27-371(J)AT TIME OF INSPECTION OBSERVED 1ST FL BEDROOMS & 2ND FL BEDROOMS DOORS W/LOCKING DEVICES INSTALLED #35421661K | Aug 6, 2019 DEFAULT | $3,125 |
| May 2, 2019 | Construction CLASS - 2 OCCUPANCY CONTRARY TO THAT ALLOWED BY THE CERTIFICATE OR BUILDING DEPARTMENT RECORDS.1ST& 2ND STORY OCCUPIED AND ARRANGE AS A S.R.O WITH PARTITIONS ERECTED THROUGHOUT.WITH A KITCHEN AND BATHROOM FACILITIES INST #35243171Z | Nov 19, 2019 DEFAULT | $6,250 |
| Apr 27, 2019 | Construction CLASS - 2 FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION #35329568Y ISSUED ON 05/01/2018 AND TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28-201.1 AND 1RCNY 102-01.OCCUPANCY CONTRARY TO #35398306N | Jul 2, 2019 DEFAULT | $5,000 |
| Apr 25, 2019 | Construction CLASS - 2 OCCUPANCY CONTRARY TO THAT ALLOWED BY THE CERTIFICATE OF OCCUPANCY OF BUILDING DEPARTMENT RECORDED 2ND FLOOR OCCUPANCY AND ARRAINGED AS A SRO WITH PARTITIONS ERECTED THROUGOUT KITCHEN AND BATHROOM FACILITIES IN #35243329J | Dec 17, 2019 DEFAULT | $6,250 |
| Apr 25, 2019 | Construction CLASS - 2 OCCUPANCY CONTRARY TO THAT ALLOWED BY THE CERTIFICATE OF OCCUPANCY OR BUILDING DEPARTMENT RECORDS.1ST FL OCCUPIED AND ARRAINGED AS AN SRO WITH PARTITIONS ERECTED THROUGHOUT KITCHEN AND BATHROOM FACILITIES INSTA #35243328H | Dec 17, 2019 DEFAULT | $6,250 |
| Feb 22, 2019 | Construction CLASS - 2 FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#35329568Y ISSUED ON 05-01-18 & TO FILE A C OF C PURSUANT TO 28-201.1 & 1RCNY 102-01. OCCUPANCY CONTRARY TO THAT ALLOWED BY THE CERT OF OCCUPANCY OR #35394400L | Apr 30, 2019 DEFAULT | $3,125 |
| Nov 7, 2018 | Construction CLASS - 2 FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#35329568Y ISSUED ON 05-10-18 & TO FILE A C OF C PURSUANT TO 28-201.1 & 1RCNY 102-01. REMEDY: COMPLY W/COMM'S ORDER &/OR FILE A C OF C. #35395993K | Jan 15, 2019 DEFAULT | $3,125 |
| Sep 17, 2018 | Construction CLASS - 2 FAILURE TO COMPLY W/THE COMM'S ORDER CONTAINED IN SUMMONS/VIO#35329568Y ISSUED ON 05-01-18 & TO FILE A C OF C PURSUANT TO 28-201.1 & 1RCNY 102-01. OCCUPANCY CONTRARY TO THAT ALLOWED BY THE C OF O OR DOB RECORDS #35387739P | Nov 13, 2018 DEFAULT | $3,125 |
| Jul 3, 2018 | Construction CLASS - 2 FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION #35329568Y ISSUED 05/01/18 AND TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28-201.1 AND 1RCNY 102-01. OCCUPANCY CONTRARY TO THA #35340008N | Aug 21, 2018 DEFAULT | $3,125 |
| Jun 22, 2018 | Construction CLASS - 2 OCCUPANCY CONTRARY TO THAT ALLOWED BY THE CERTIFICATE OF OCCUPANCY OR BUILDING DEPARTMENT RECORDS.1ST AND 2ND STORY USE CHANGED FROM STORAGEAND ORDINARY USE TO AND APARTMENT PARTITIONS ERECTED WITH KITCHEN AND #35242777Z | Feb 5, 2019 DEFAULT | $6,250 |
| May 1, 2018 | Construction CLASS - 1 OCCUPANCY CONTRARY TO THAT ALLOWED BY THE C OF O OR BUILDING DEPARTMENT RECORDS. NOTED: DOB'S RECORDS INDICATES RESIDENCE AS 2 FAMILY, ONE FAMILY AT 1ST FLOOR AND ONE FAMILY AT 2ND FLOOR AND CELLAR FOR BOILER A #35329568Y | Jun 19, 2018 WRITTEN OFF | $0 |
| Nov 15, 2017 | Construction CLASS - 1 RESIDENCE ALTERED FOR OCCUPANCY AS A DWELLING 1 OR 2 FAMILIES TO 4 OR MORE FAMILIES. NOTED: DOB'S RECORDS INDICATES RESIDENCE AS 2 FAMILY,1 FAMILY PER(1ST & 2ND FL),CELLAR(BOILER & STORAGE)RESIDENCE. NEW ALTERE #35301926K | Jan 2, 2018 DEFAULT | $57,000 |
| Nov 15, 2017 | Construction CLASS - 2 WORK W/O A PERMIT. NOTED: AT 2ND FL LEVEL FULL HEIGHT PARTITION WALLS & DOOR W/KEY LOCKING DEVICE ERECTED,CREATED A ROOM W/O LIGHT & VENTILATION. REMEDY: OBTAIN PERMIT. #35301927M | Jan 2, 2018 WRITTEN OFF | $0 |
| Nov 14, 2017 | Construction CLASS - 2 OCCUPANCY CONTRARY TO THAT ALLOWED BY THE C OF O OR DOB RECORDS. 1ST & 2ND STORY IS CONVERTED INTO SINGLE ROOM OCCUPANCY & ARRANGED AS A SRO PARTITIONS ERECTED W/ KITCHEN & BATHROOM FACILITIES INSTALLED. #35241738L | Aug 21, 2018 DEFAULT | $6,000 |
| Issued | Violation | Status |
|---|---|---|
| Jul 25, 2018 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00517 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Jul 25, 2018 | AEUHAZ FTC-AEU-HAZ | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Jun 27, 2025 | I | §27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID R | — |
| Aug 24, 2026 | B | Apt 2 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ FT AT WEST WALL IN THE KITCHEN LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST ORIGINAL VIOLATION 18803660 ISSUED 21-APR-26 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE 27-2017. | Sep 28, 2026 |
| Apr 22, 2026 | C | Apt 2 · § 27-2031 ADMIN. CODE: PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | Apr 22, 2026 |
| Apr 22, 2026 | C | Apt 2 · § 27-2024 ADMIN. CODE: PROVIDE ADEQUATE SUPPLY OF COLD WATER FOR THE FIXTURES AT WASH BASIN IN THE BATHROOM LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | Apr 28, 2026 |
| Apr 22, 2026 | C | Apt 2 · § 27-2024 ADMIN. CODE: PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES AT WASH BASIN IN THE BATHROOM LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | Apr 28, 2026 |
| Apr 22, 2026 | B | Apt 2 · § 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR THE CEILING IN THE PRIVATE HALLWAY LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | May 27, 2026 |
| Apr 22, 2026 | B | Apt 2 · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | May 27, 2026 |
| Apr 22, 2026 | B | Apt 2 · § 27-2005 ADMIN. CODE: REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER THE CEILING IN THE PRIVATE HALLWAY LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | May 27, 2026 |
| Apr 22, 2026 | A | Apt 2 · § 27-2013 ADMIN. CODE: PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE NORTH WALL IN THE BATHROOM LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | Jul 26, 2026 |
| Mar 30, 2026 | B | Apt 2 · § 27-2005 ADMIN. CODE: REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING IN THE 1st ROOM FROM NORTH LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | May 4, 2026 |
| Mar 30, 2026 | B | Apt 2 · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | May 4, 2026 |
| Mar 30, 2026 | B | Apt 2 · § 27-2026 ADMIN. CODE: REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT SINK IN THE KITCHEN LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | May 4, 2026 |
| Mar 30, 2026 | B | Apt 2 · § 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE RUBBER GASKET AT REFRIGERATOR IN THE KITCHEN LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | May 4, 2026 |
| Mar 30, 2026 | B | Apt 2 · § 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR AT ALL WALLS AND CEILING IN THE KITCHEN LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | May 4, 2026 |
| Mar 30, 2026 | B | Apt 2 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GREATER THAN 10 SQUARE FEET AT CEILING IN THE 4th ROOM FROM NORTH LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | May 4, 2026 |
| Mar 30, 2026 | B | § 27-2010, 2011, 2012 ADMIN. CODE: REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE SOUTH YARD YARD, 1st STORY | May 4, 2026 |
| Mar 30, 2026 | B | Apt 2 · § 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR AT ALL WALLS AND CEILING IN THE BATHROOM LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | May 4, 2026 |
| Mar 30, 2026 | B | Apt 2 · § 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC WALL TILES AT WEST WALL AT SHOWER IN THE BATHROOM LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | May 4, 2026 |
| Mar 30, 2026 | B | Apt 2 · § 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR AT ALL WALLS AND CEILING IN THE PRIVATE HALLWAY LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | May 4, 2026 |
| Mar 30, 2026 | C | Apt 2 · § 27-2005 ADMIN. CODE: REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING IN THE PRIVATE HALLWAY LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Apr 5, 2026 |
| Mar 30, 2026 | B | Apt 2 · § 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR AT ALL WALLS AND CEILING IN THE 1st ROOM FROM NORTH LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | May 4, 2026 |
| Mar 24, 2026 | B | Apt 2NDFLO · § 27-2005 ADMIN. CODE: REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING IN THE PRIVATE HALLWAY LOCATED AT APT 2NDFLO, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH | Apr 28, 2026 |
| Mar 24, 2026 | B | Apt 2NDFLO · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GREATER THAN 10 SQUARE FEET AT CEILING IN THE 3rd ROOM FROM NORTH LOCATED AT APT 2NDFLO, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH | Apr 28, 2026 |
| Mar 24, 2026 | B | Apt 2 · § 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC WALL TILES AT WEST WALL AT SHOWER IN THE BATHROOM LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH | Apr 28, 2026 |
| Mar 24, 2026 | B | Apt 2NDFLO · § 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE AT ALL WALLS AND CEILING IN THE KITCHEN LOCATED AT APT 2NDFLO, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH | Apr 28, 2026 |
| Mar 24, 2026 | B | Apt 2 · § 27-2026 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE CONNECTION AT WASTE LINE AT WASH BASIN IN THE BATHROOM LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH | Apr 28, 2026 |
| Mar 24, 2026 | B | Apt 2 · § 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR AT ALL WALLS AND CEILING IN THE BATHROOM LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH | Apr 28, 2026 |
| Mar 24, 2026 | B | Apt 2NDFLO · § 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR AT ALL WALLS AND CEILING IN THE PRIVATE HALLWAY LOCATED AT APT 2NDFLO, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH | Apr 28, 2026 |
| Mar 24, 2026 | B | Apt 2NDFLO · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2NDFLO, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH | Apr 28, 2026 |
| Mar 24, 2026 | B | Apt 2NDFLO · § 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD DOOR FRAME IN THE 3rd ROOM FROM NORTH LOCATED AT APT 2NDFLO, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH | Apr 28, 2026 |
| Mar 24, 2026 | B | Apt 2NDFLO · § 27-2026 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE CONNECTION AT WASTE LINE AT WASH BASIN IN THE BATHROOM LOCATED AT APT 2NDFLO, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH | Apr 28, 2026 |
| Mar 24, 2026 | B | Apt 2NDFLO · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE WOOD DOOR LEADING TO KITCHEN IN THE PRIVATE HALLWAY LOCATED AT APT 2NDFLO, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH | Apr 28, 2026 |
| Mar 24, 2026 | B | Apt 2NDFLO · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 2NDFLO, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH | Apr 28, 2026 |
| Mar 24, 2026 | B | Apt 2NDFLO · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE WOOD DOOR AT ENTRANCE IN THE 2nd ROOM FROM NORTH LOCATED AT APT 2NDFLO, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH | Apr 28, 2026 |
| Mar 24, 2026 | B | Apt 2NDFLO · § 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR AT ALL WALLS AND CEILING IN THE 3rd ROOM FROM NORTH LOCATED AT APT 2NDFLO, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH | Apr 28, 2026 |
| Mar 24, 2026 | B | Apt 2NDFLO · § 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 3rd ROOM FROM NORTH LOCATED AT APT 2NDFLO, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH | Apr 28, 2026 |
| Mar 24, 2026 | B | Apt 2 · § 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE PRIVATE HALLWAY LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH | Apr 28, 2026 |
| Mar 24, 2026 | B | Apt 2 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH | Apr 28, 2026 |
| Mar 24, 2026 | B | Apt 2 · § 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD DOOR FRAME IN THE 3rd ROOM FROM NORTH LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH | Apr 28, 2026 |
| Mar 24, 2026 | B | Apt 2 · § 27-2005 ADMIN. CODE: PROPERLY SECURE THE LOOSE HAND RAIL IN THE PRIVATE HALLWAY LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH | Apr 28, 2026 |
| Mar 24, 2026 | B | § 27-2010, 2011, 2012 ADMIN. CODE: REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE AT SOUTH YARD YARD | Apr 28, 2026 |
| Mar 24, 2026 | B | Apt 2NDFLO · § 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES AT WEST WALL IN THE PRIVATE HALLWAY LOCATED AT APT 2NDFLO, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH | Apr 28, 2026 |
| Mar 2, 2026 | B | Apt 2NDFLO · § 27-2005 ADMIN. CODE: REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER THE CEILING IN THE BATHROOM LOCATED AT APT 2NDFLO, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH | Apr 6, 2026 |
| Mar 2, 2026 | B | Apt 2NDFLO · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT THE NORTH WALL IN THE BATHROOM LOCATED AT APT 2NDFLO, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH | Apr 6, 2026 |
| Mar 2, 2026 | B | Apt 2NDFLO · § 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR AT THE CEILING IN THE PRIVATE HALLWAY LOCATED AT APT 2NDFLO, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH | Apr 6, 2026 |
| Mar 2, 2026 | B | Apt 2NDFLO · § 27-2005 ADMIN. CODE: REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER THE CEILING IN THE PRIVATE HALLWAY LOCATED AT APT 2NDFLO, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH | Apr 6, 2026 |
| Mar 2, 2026 | B | Apt 2NDFLO · § 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC WALL TILES APPROXIMATE 8SQ FEET AT THE WEST WALL IN THE BATHROOM LOCATED AT APT 2NDFLO, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH | Apr 6, 2026 |
| Mar 2, 2026 | B | Apt 2NDFLO · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE WASH BASIN CABINET IN THE BATHROOM LOCATED AT APT 2NDFLO, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH | Apr 6, 2026 |
| Mar 2, 2026 | B | Apt 2NDFLO · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE ENTRANCE DOOR AT EAST IN THE 2nd ROOM FROM NORTH LOCATED AT APT 2NDFLO, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH | Apr 6, 2026 |
| Mar 2, 2026 | B | Apt 2NDFLO · § 27-2026 ADMIN. CODE: REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT THE WASH BASIN AND BATHTUB IN THE BATHROOM LOCATED AT APT 2NDFLO, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH | Apr 6, 2026 |
| Mar 2, 2026 | B | Apt 2NDFLO · § 27-2005 ADMIN. CODE: PROPERLY SECURE THE LOOSE WOODEN BANISTER IN THE PRIVATE HALLWAY LOCATED AT APT 2NDFLO, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH | Apr 6, 2026 |
| Mar 2, 2026 | B | Apt 2NDFLO · § 27-2026 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE CONNECTION WASTE LINE UNDER THE WASH BASIN CABINET IN THE BATHROOM LOCATED AT APT 2NDFLO, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH | Apr 6, 2026 |
| Mar 2, 2026 | B | Apt 2NDFLO · § 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 4th ROOM FROM NORTH AT WEST LOCATED AT APT 2NDFLO, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH | Apr 6, 2026 |
| Feb 25, 2026 | B | Apt 2NDFLO · § 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES WEST WALL IN THE BATHROOM LOCATED AT APT 2NDFLO, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH | Apr 1, 2026 |
| Feb 25, 2026 | C | Apt 2NDFLO · § 27-2005 ADMIN. CODE: REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING IN THE 1st ROOM FROM NORTH LOCATED AT APT 2NDFLO UPPER LEVEL, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH | Mar 3, 2026 |
| Feb 25, 2026 | C | Apt 2 · § 27-2031 ADMIN. CODE: PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE 2nd ROOM FROM NORTH LOCATED AT APT 2 UPPER LEVEL, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH | Feb 25, 2026 |
| Feb 25, 2026 | B | § 27-2005 ADMIN. CODE: REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING AT PUBLIC HALL, 2nd STORY | Apr 1, 2026 |
| Feb 25, 2026 | B | § 27-2005 ADMIN. CODE: PROPERLY SECURE THE LOOSE HANDRAIL AT PUBLIC HALL STAIRS AT PUBLIC HALL, 2nd STORY | Apr 1, 2026 |
| Feb 25, 2026 | B | § 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR AT CEILING AT PUBLIC HALL, 2nd STORY | Apr 1, 2026 |
| Feb 25, 2026 | C | Apt 2NDFLO · § 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR AT CEILING IN THE 1st ROOM FROM NORTH LOCATED AT APT 2NDFLO UPPER LEVEL, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTH | Mar 3, 2026 |
Showing 60 of 236. Full list on the agency site.
| Date | Source | What | Now |
|---|---|---|---|
| Oct 13, 2026 | ECB | Construction: OBSERVED VERTICAL AND HORIZONT CARKS ON THE BUILDING AT ROOF LEVEL AND ON THE SIDE OF THE BUILDING NEXT TO EXPOSURE 2 SIDE., REPAIR AND/REPLACE | Open |
| Aug 24, 2026 | HPD B | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ FT AT WEST WALL IN THE KITCHEN LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST ORIGINAL VIOLATION 18803660 ISSUED 21-APR-26 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE 27-2017. | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 17, 2026, 4:16 PM ET. BBL 4101210068.