2 floors · 25,725 sq ft · built 1953 · class RB · owner of record: 1527 Southern Fee Owner Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 60 days | Keep the report on file (not filed with DOB) |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2023-10-17 (Accepted). Agency page | Dec 31, 2026 in 60 days | 1 of 1 without an accepted 2026 report yet |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 25,725 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 181 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 181 days | Annual filing |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 3 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 791 days | Next cycle year 2028 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Mar 18, 2026 | Construction CLASS - 1 OBSERVED, PAINTED SPRINKLER CAPS ON THE SECOND FLOOR. LAUNDRY ROOM ON SECOND FLOOR EXHAUST VENT NOT INSTALLED PROPERLY. MISSING TRAP WRAPS IN THE BATHROOMS ON FIRST AND SECOND FLOOR, ALSO RESTRICTED SPRINKLER H #39180882P | Nov 6, 2026 ADMIT/IN-VIO | $0 |
| Mar 18, 2026 | Construction CLASS - 1 OBSERVED REQUIRED 5 YEAR HYDROSTATIC PRESSURE TEST OF THE STANDPIPE SYSTEM WAS NOT AVAILABLE DURING TIME OF INSPECTION WHICH IS CONTRARY TO FIRE CODE 901.6 AND NFPA 25 ALSO WATER DOESN'T SHUT OFF ON THE SINK ON #39180881N | Nov 6, 2026 ADMIT/IN-VIO | $0 |
| Nov 14, 2025 | Boilers CLASS - 2 AT TIME OF INSPECTION I FOUND TWO OUT OF THREE A.O.SMITH BTH500-300 HOT WATER HEATERS NOT OPERATIONAL, MAINTAIN BOILER; CORRECT ALL VIOLATING CONDITION/ SUBMIT CERTIFICATE OF CORRECTION #39166978Z | Jan 30, 2026 ADMIT/IN-VIO | $0 |
None open.
| Issued | Violation | Status |
|---|---|---|
| Sep 25, 2026 | Benchmarking - LL84 DQ-EN-BENCH FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 | Active |
| Aug 5, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Aug 5, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Sep 25, 2026 | DOB Safety | Benchmarking - LL84: FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 | Open |
| Aug 5, 2026 | DOB Safety | AEUHAZ: | Open |
| Aug 5, 2026 | DOB Safety | AEUHAZ: | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 1, 2026, 6:24 AM ET. BBL 2029777501.