18open violations
$27,500ECB/OATH penalties owed
0HPD class C (immediately hazardous)
47dto Annual boiler inspection (1 boiler)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 47 days
Keep the report on file (not filed with DOB)
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2024-09-27 (Accepted). Agency page

Dec 31, 2026
in 47 days
1 of 1 without an accepted 2026 report yet
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 3 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 778 days
Next cycle year 2028

Open violations

ECB / OATH (4) · $27,500 owed
IssuedViolationHearingBalance
Dec 6, 2019Construction CLASS - 1
I OBSERVED IN CELLAR OF FLORIST SHOP NEWLY INSTALLED GAS PIPING, FITTINGS AND WATER HEATER AND NO PERMITS ON FILE, OBTAIN PERMIT
#39013977J
Jun 4, 2021
DEFAULT
$12,500
Dec 6, 2019Plumbing CLASS - 2
I OBSERVED IN CELLAR OF FLORIST SHOP PVC PIPING INSTALLED FOR SANITARY LINE WHICH IS PROHIBITED AND NOT CODE COMPLAINT, REMOVE NON-COMPLYING MATERIAL OR EQUIPMENT
#39013975X
Feb 8, 2021
IN VIOLATION
$1,250
Dec 6, 2019Construction CLASS - 1
FUTURE GAS CONNECTION; I OBSERVED IN CELLAR OF DELI GAS METER FOR FLORIST AND FUTURE GAS CONNECTION ON MAIN GAS LINE WHICH IS PROHIBITED AND NOT CODE COMPLAINT, REPAIR AND/REPLACE
#39013976H
Jun 4, 2021
IN VIOLATION
$1,250
Dec 6, 2019Plumbing CLASS - 1
I OBSERVED IN CELLAR FLORIST SHOP NEWLY INSTALLED WATER HEATER AN GAS PIPING WITH FITTINGS AND NO PERMITS ON FILE; THEREFORE NO PROPER TESTING WAS PERFORMED ON GAS LINE AS PER DOB, PERFORM TEST
#39013978L
Dec 10, 2021
DEFAULT
$12,500
DOB (8)
IssuedViolationStatus
Mar 4, 2020FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00361
DOB VIOLATION - ACTIVE
Mar 4, 2020FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00363
DOB VIOLATION - ACTIVE
Mar 4, 2020FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00362
DOB VIOLATION - ACTIVE
Apr 6, 2018LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2016 INSPECTION REPORT
#13656
DOB VIOLATION - ACTIVE
Feb 24, 2017LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2015 INSPECTION REPORT
#11083
DOB VIOLATION - ACTIVE
Feb 20, 1996CONSTRUCTION

#03AM02
VIOLATION WORK WITHOUT PERMIT - ACTIVE
Feb 20, 1996CONSTRUCTION

#03AM01
DOB VIOLATION - ACTIVE
Aug 16, 1993LOCAL LAW 62/91 - BOILERS

#26927
DOB VIOLATION - ACTIVE
DOB NOW Safety (6)
IssuedViolationStatus
Jan 8, 2026Gas Piping - LL152 FTF-PL-PER
Cycle 2, Sub-cycle A (premises is in Community District 3)
Active
Mar 4, 2020AEUHAZ FTC-AEU-HAZ
Active
Mar 4, 2020AEUHAZ FTC-AEU-HAZ
Active
Mar 4, 2020AEUHAZ FTC-AEU-HAZ
Active
Apr 6, 2018Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2016 INSPECTION REPORT
Active
Feb 24, 2017Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2015 INSPECTION REPORT
Active
HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)