| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 44 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 44 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 60 days | Annual |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 288 days | Registered through 2027-09-01 |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 10 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 775 days | Next cycle year 2028 |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-08-03 (Accepted). Agency page | On file | 2026 reports accepted |
None open.
None open.
None open.
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Feb 10, 2026 | B | Apt 1B · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SHUT OFF VALVE AT RADIATOR IN THE 1st ROOM FROM EAST LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH | Mar 17, 2026 |
| Jul 26, 2023 | B | Apt 4B · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PORCELAIN FINISH AT BATHTUB IN THE BATHROOM LOCATED AT APT 4B, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH | Aug 30, 2023 |
| Dec 2, 2015 | A | Apt 1B · § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION CONSISTING OF ACOUSTIC TILE DROP CEILING & FRAME INSTALLED IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 1B, 1st STORY, 1st APARTMENT F | Mar 6, 2016 |
| Dec 2, 2015 | A | Apt 1B · § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION CONSISTING OF ACOUSTIC TILE DROP CEILING & FRAME INSTALLED IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 1B, 1st STORY, 1st APARTMENT F | Mar 6, 2016 |
| Dec 2, 2015 | A | Apt 1B · § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION CONSISTING OF ACOUSTIC TILE DROP CEILING & FRAME INSTALLED IN THE KITCHEN LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH | Mar 6, 2016 |
| Dec 2, 2015 | B | Apt 1B · § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH | Jan 6, 2016 |
| Jul 29, 2015 | A | Apt 1B · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING AND WALLS IN THE ENTIRE APARTMENT LOCATED AT APT 1B, 1st STORY, 1st APARTMENT FROM NORTH AT EAST | Nov 1, 2015 |
| Aug 21, 2007 | B | Apt 2E · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES AT 2ND STY EAST APT 2E BATHROOM. , SECTION '' '' | Sep 25, 2007 |
| Aug 21, 2007 | B | Apt 2E · § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE 2ND STY EAST APT 2E WASH BASIN BATHROOM. , SECTION '' '' | Sep 25, 2007 |
| Aug 21, 2007 | B | Apt 2E · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRICAL CLG LIGHT FIXTURE AT FOYER IN 2ND STY EAST APT 2E. LOCATED AT APT 2E | Sep 25, 2007 |
| Aug 21, 2007 | A | Apt 2E · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE MARBLE SADDLE AT 2ND STY EAST APT 2E BATHROOM. , SECTION '' '' | Nov 24, 2007 |