Manhattan · Block 2009 · Lot 12 · 10030

151 West 140 Street

7 floors · 55 apartments · 70,509 sq ft · built 1903 · class D1 · owner of record: Maxwell Development L

237open violations
$77,812ECB/OATH penalties owed
35HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueRegistration expired 2025-09-01
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 58 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 58 days
Annual
Annual boiler inspection (2 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2021-09-10 (Accepted). Agency page

Dec 31, 2026
in 58 days
2 of 2 without an accepted 2026 report yet
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 74 days
Annual
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 70,509 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 179 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 179 days
Annual filing
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 10 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 789 days
Next cycle year 2028
Energy audit and retro-commissioning (2029) Likely applies
Local Law 87 · Calendar year 2029
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 2009). Agency page

Dec 31, 2029
in 1154 days
Next due 2029
Facade inspection report (Cycle 10A) Applies
Local Law 11 / FISP · Feb 21, 2025 to Feb 21, 2027
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 4, 5, 6 or 9 are in sub-cycle 10A. DOB facade records for this building show $2,442,300 in late-filing or failure-to-file penalties. Agency page

On fileCycle 10 filing on record: SAFE (2025-08-11)

Open violations

ECB / OATH (25) · $77,812 owed
IssuedViolationHearingBalance
Aug 21, 2025Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING WALLS OR APPURTENANCES. AT TIME OF INSPECTION, I OBSERVED DAMAGED MASONRY WALL 1 VERTICAL CRACKS OF PARAPET LEVEL AND MULTIPLE VERTICAL CRACKS FROM 3RD FLOOR LEVEL TO 6 FLOOR LEVEL
#35718455R
Oct 30, 2025
IN VIOLATION
$1,250
Mar 21, 2025Unknown CLASS - 2
EXPIRED SIDEWALK SHED PERMIT. AS NOTED: AT TIME OF INSPECTION, SIDEWALK SHED PERMIT WAS EXPIRED AND NO NEW PERMIT WAS PULLED. REMEDY: RENEW PERMIT.
#35689271M
Jul 9, 2026
IN VIOLATION
$0
Oct 1, 2024Unknown CLASS - 2
EXPIRED SIDEWALK SHED PERMIT. AS NOTED, AT THE TIME OF INSPECTION, SIDEWALK SHED PERMIT WAS EXPIRED. REMEDY: RENEW PERMIT.
#35686246R
Jan 16, 2025
IN VIOLATION
$3,125
Jun 27, 2024Unknown CLASS - 2
TEMPORARY CONSTRUCTION EQUIPMENT INSTALLATION ON SITE HAS EXPIRED PERMIT. AT TIME OF INSPECTION OBSERVED SHED IN PLACE AND NO VALID PERMIT ON BIS OR DOB NOW. REMEDY: RENEW PERMIT.
#35685364N
Sep 5, 2024
DEFAULT
$10,000
Apr 22, 2024Construction CLASS - 1
UNLAWFUL ACTS. FAILURE TO COMPLY COMMISSIONER'S ORDER. NOTE: RESPONDENT FAILURE TO COMPLY PRIOR SUMMON #35679609L DATED(01/10/24) AND DOB VIO #01102024SR1002RF DATED(01/10/34). AT TIME OF INSPECTION, I OBSERVED
#35681926H
Jun 27, 2024
DEFAULT
$12,500
Jan 10, 2024Unknown CLASS - 2
TEMPORARY CONSTRUCTION EQUIPMENT INSTALLATION ON SITE HAS EXPIRED PERMIT.REMEDY:RENEW PERMIT.
#35679608J
Mar 21, 2024
DEFAULT
$6,250
Jan 10, 2024Construction CLASS - 1
FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAYS.AS NOTED:AT TIME OF INSPECTION OBSERVED ON FIRE ESCAPES ON EXP #1 SOUTH ELEVATION & EXP #3 NORTH ELEVATION CONDITIONS ARE HAZARDOUS WHEN ESCAPE FIRE VIA FIRE ESC
#35679607H
Mar 21, 2024
DEFAULT
$6,250
Jan 10, 2024Construction CLASS - 1
UNLAWFUL ACTS.FAILURE TO COMPLY WITH COMMISSIONER'S ORDER.AS NOTED:AT TIME OF INSPECTION RESPONDENT FAILED TO COMPLY WITH COMMISSIONER'S ORDER. AS PER PREVIOUS VIOLATION #35674568L(ECB) AND DOB #09192023SR1002R
#35679609L
Mar 21, 2024
DEFAULT
$6,250
Sep 19, 2023Construction CLASS - 1
FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGE WAY AS NOTED: AT TIME OF INSPECTION I OBSERVED ON EXPOSURE #3 OBJECTS ON FIRE ESCAPE CREATING A HAZARDOUS OBSTRUCTION WHEN EGRESSING THE FIRE ESCAPE. REMEDY: REMOVE
#35674568L
May 23, 2024
IN VIOLATION
$1,250
Aug 22, 2023Elevators CLASS - 2
2X10 32L11 39X10 2 OUTSIDE COMMUNICATION(PHONE)INOPERATIVE MUST REPAIR IMMEDIATELY /32-CAR GUIDE ROLLERS DEFECTIVE MAKING NOISE MUST REPLACE./39-TOP OF CAR LIGHT INOPERATIVE MUST REPAIR.
#38274866X
Mar 21, 2024
IN VIOLATION
$625
May 1, 2022Construction CLASS - 2
TEMPORARY CONSTRUCTION EQUIPMENT ONSITE-EXPIRED PERMIT.THIS VIOLATION IS FOR A EXPIRED SCAFFOLD PERMIT AT THIS SITE.REM:RENEW PERMIT.
#39501096M
Sep 22, 2022
DEFAULT
$6,250
Oct 8, 2021Local Law CLASS - 2
FAILURE TO FILE ACCEPTABLE AMENDED CYCLE 7A & 8A REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL FACADES REPORT REQUIRED BY 28-302.5 FOR CONTROL#806898. REMEDY: FILE ACCEPTABLE REPORT.
#37022242K
Mar 3, 2022
DEFAULT
$6,250
Aug 22, 2021Construction CLASS - 2
EXPIRED PERMIT:PERMIT #140950193-01-AL ISSUED 09/17/20 EXPIRED 07/15/21 FOR FACADE WORK AND PIPE SCAFFOLDING.REMEDY:RENEW PERMIT.
#35581501Y
Nov 4, 2021
IN VIOLATION
$0
Aug 21, 2021Construction CLASS - 2
3314.4.8,3314.8 MAINTENANCE OF SCAFFOLD ALL COMPETENTS AND ATTACHEMENTTO THE SCAFFOLD FAILURE TO COMLY WITH CODES.NOTE 17 STORY RESIDENTIAL BUILDING WITH SWS AND PIPE SCAFFOLD ON TOP COMBINE HEIGHT OF 70FT INAD
#35583163J
Nov 4, 2021
DEFAULT
$6,250
Aug 21, 2021Construction CLASS - 2
TEMPORARY CONSTRUCTION EQUIPMENT ONSITE-EXPIRED PERMIT.NOTE OBSERVED SIDEWALK SHED WITH SUPPORTED SCAFFOLD ON TOP COMBINED HEIGHT OF 60FT REVIEW OF PERMIT FOR SCAFFOLD#M00097486 EXPIRED 3/5/2021 CONTRACTOR FAIL
#35583162H
Nov 4, 2021
DEFAULT
$6,250
Feb 6, 2020Elevators CLASS - 1
NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC. THIS IS A CONTROLLER FEATURE WHICH ENSURES PASSENGER SAFETY. REMEDY; FILE APPLICATION, INSTALL DLM A
#39016989K
Oct 22, 2020
IN VIOLATION
$1,250
Apr 18, 2019Elevators CLASS - 2
31L10 LEVELING UNIT DEFECTIE, ELEVATOR COMES TO A HARD AND SUDDEN STOP AT ALL FLOORS GOING BOTHUP AND DOWN, REPAIR.
#38269330L
Dec 12, 2019
IN VIOLATION
$0
Feb 12, 2019Boilers CLASS - 2
B254,21C,24B,50,50A. 21C-OIL RETURN LINES SHALL NTO HAVE SHUT OFF VALVES W/O PROTECTION. 24B-REMOTE CONTROL SWITCH MISSING AT 2ND DOOR; 50-BOILER RELIEF VALVE DISCHARGE NOT SUPPORTED; 50A-PLUG OPEN END VALVES
#32096369H
Apr 11, 2019
DEFAULT
$1,562
Jan 5, 2019Elevators CLASS - 1
97X17 ONLY ELEVATOR IN BUILDING IS OUT OF SERVICE. UPON INSPECTION THIS DEVICE WAS FOUND TO BE OUT OF SERVICE CRETING A HAZARDOUS CONDI TION AS PER 1RCNY 11-2. RMDY: RESTORE TO SERVICE IMMEDIATELY AND NOTIF
#38267454Y
Feb 28, 2019
IN VIOLATION
$1,250
Dec 24, 2018Elevators CLASS - 1
2X10,5A10,57BB7,59BB7,100I10. 2X10-OUTSIDE COMM INOPERATIVE REPAIR; 5A10-CAR DOOR RESTRICTOR ALTERED REPAIR; 57BB7-FIRE EXTINGUISHER; BB-PROVIDE 59BB7-MACHINE BRAKE TAG; BB-PROVIDE 100I10-INSIDE CAB WALL FORMI
#38266848M
May 30, 2019
IN VIOLATION
$0
Aug 1, 2018Local Law CLASS - 2
FAILURE TO FILE A ACCEPTABLE AMENDED CYCLE 8A REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL FACADE REPORT REQUIRED BY 28-302.5 FOR CONTROL # 806898. AGG 1: PRIOR NOV 37001469M UNDER 28-
#37012123Z
Jan 24, 2019
IN VIOLATION
$1,250
Nov 7, 2016Local Law CLASS - 2
FAILURE TO FILE ACCEPTABLE AMENDED REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL LOCAL LAW 11/98 REPORT. REMEDY: FILE ACCEPTABLE AMENDED REPORT.
#37001469M
Feb 23, 2017
IN VIOLATION
$0
Jan 14, 2016Construction CLASS - 2
FAILURE TO MAINTAIN EXTERIOR BLDG ROOF-PARAPET VERTICLE CRACKS,CRACKING SOUTH ELEV.EXP#1-OBJECTS ON FIRE-ESCAPES FLOWER POTS (LANDING 1,3) CRACKED WINDOW SILLS:3FL 4FL (COVER ENTRY) 3FL CRACKED MASONRY BAN WEST
#35133947J
Mar 3, 2016
IN VIOLATION
$0
Sep 15, 2015Local Law CLASS - 2
FAIL TO FILE AN ACCEPTABLE TECH REPORT IN COMPLIANCE W/CODE PROVISIONS:NOV #36019085M PERIODIC INSPECTION OF EXTERIOR WALLS & APPURTENANCES AS REQ.REM:FILE REQUIRED REPORT TO DOB.
#36027949K
Mar 31, 2016
WRITTEN OFF
$0
Sep 1, 2015Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING WALLS AND APPURTENANCES. NOTED AT EXP1- I-SPALLED DECORATIVE STONE BETWEEN FLRS 2 AND 3 AT MIDST SECTION; II- SPALLED AND CRACKED SILL AT 3/F; III-CRACK WAS FOUND AT ANCHORAGE AT
#35133485Y
Oct 22, 2015
DEFAULT
$0
DOB (46)
IssuedViolationStatus
Nov 14, 2025LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
#04360
DOB VIOLATION - ACTIVE
Nov 14, 2025LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
#04361
DOB VIOLATION - ACTIVE
Mar 21, 2025CONSTRUCTION
FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER.NOTE AT EXP2,3 ,4 OBSERVED MULTIPLE AREAS IF STEP CRACKS AT VARIOUS LEVELS(PARAPET,WI NDOWS)OBSERVED MULTIPLE AREAS OF SPALLING DETERIORATED JOINTS AT VARIO US LEVELS.CRACKS DOWN EXP1 CHIMNEY.REMEDY:REPAIR AND/OR REPLACE
#SR11001DO
DOB VIOLATION - ACTIVE
Dec 1, 2024FAILURE TO POST ENERGY GRADE/SCORE
FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3
#2400485
DOB VIOLATION - ACTIVE
Oct 1, 2024CONSTRUCTION
FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER.AS NOTED AT TI ME OF INSPECTION,I OBSERVED ON EXP1 SOUTH ELEV CRACKS IN STUCCO AT PAR APET WALL.EXP2 WEST ELEV,EXP3 & 4 CRACKS IN SPANDRELS ON MULTIPLE FLOO RS.EXP3 NORTH ELEV,ERODING BRICKS AND MORTAR JOINT AT SEVERAL FLOORS.R OOF CRACKS IN PA
#SR1001RF
DOB VIOLATION - ACTIVE
Sep 23, 2024LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL LOW PRESSURE INSPECTION
#04271
DOB VIOLATION - ACTIVE
Sep 23, 2024LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL LOW PRESSURE INSPECTION
#04270
DOB VIOLATION - ACTIVE
Jun 27, 2024CONSTRUCTION
FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER.AT TIME OF INS PECTION OBSERVED AT EXP1 PARAPET LEVEL,STUCCO CRACK ALONG THE WHOLE PA RAPET INTERIOR,EXTERIOR.AT EXP1 OBSERVED CRACKED WINDOW SILL.AT EXP2 O BSERVED STEP CRACKS.OBSERVED CRACKED STUCCO AT PARAPET.EXP3 OBSERVED S TEP CRACK MISSIN
#SR11001DO
DOB VIOLATION - ACTIVE
Jun 23, 2024FAILURE TO SUBMIT EER
FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 - MULTIPLE YEARS (2023)
#00528
DOB VIOLATION - ACTIVE
Jan 10, 2024CONSTRUCTION
EMERGENCY WORK ORDER DUE TO HAZ.COND.OBJECTS ON FIRE ESCAPE EXP#1&2 CRACKS&SPALLING STUCCO&BRICK EXP#1,2,3&4&ROOF STEP CRACKS IN SPANDRELS BRICKWORK ON EXP#2&4.CRACKS IN PARAPET STUCCO ON ROOF,LOOSE OBJECTS SITTING ON ROOF.AC INADEQ.SUPPORTED ON EXP#2.REMEDY:IMMED REPAIR&/OR REPLACE DAMAGED FACADE R
#SR1002RF
DOB VIOLATION - ACTIVE
Jan 10, 2024CONSTRUCTION
FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.EXPO#1 DAMAGE SPALLING&BROKEN OFF STUCCO ON CHIMNEY,CRACKS ON PARAPET STUCCO@MULTIPL LOC.OBJECTS ON FIREESCAPE.BRICKS SITTING ON4FL WIND.SILL CAN FALL&HURT EXP#2 W.ELEV.AC INADEQ.SUPPORTED IN WIND.STEPCRACKS&SPANDRELS@SEVERAL FL.EXP#3ERODING BRIC
#SR1001RF
DOB VIOLATION - ACTIVE
Jan 3, 2024FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00028
DOB VIOLATION - ACTIVE
Sep 19, 2023CONSTRUCTION
FAIL.TO MAINT.EXTERIOR BLDG WALLS&APPURT.AS NOTED:ON EXPO#1,2,3&ROOF DEFECT.COND.WERE OBSER.EXPO#1CRACKS IN STUCCO@PARAPET CRACKED SPALLING STUCCO ON CHIMNEY.EXP2,3 STEPCRACKS IN SPANDRELS@MULTI.FL.AC INADEQATE SUPPORTED.ON EXP#2 EXP#3 OBJECTS ON FIREESCAPES,ROOF&CRACKS IN STUCCO @PARAPET,LOOSE MATE
#SR1001RF
DOB VIOLATION - ACTIVE
Sep 19, 2023CONSTRUCTION
FAILURE TO MAINTAIN EXTERIOR BUILDING WALLS AND APPURTENANCES.ON EXP#1 ,2&3 AND ROOF DEFECTIVE CONDITIONS WERE OBSERVED.ON EXPOSURE#1 CRACKS IN STUCCO@ PARAPET,CRACKS AND SPALLING STUCCO ON CHIMNEY.EXP#2&3:STEP CRACKS IN SPANDRELS@MULTIPLE FLS.AC INADEQUATE SUPPORTED.EXP#2 REMEDY: MAINT.EXTERIOR BLD
#SR1002RF
DOB VIOLATION - ACTIVE
Jun 27, 2023CONSTRUCTION
FAILURE TO MAINTAIN BUILDING & EXTERIOR FACADE&APPURTENANCES OBSERVED SPALLED STUCCO ON CHIMNEY,FLOWER POTS&A/C ON FIRE ESCAPE LANDING@EXP#1 SO.ELEV.BRICK ON WIND.SILL&DAMAGED MORTAR.JOINTS/CRACKED BRICK EXPO#2 W.ELE.OPEN MORTAR JOINTS&CRACKED STUCCO EXP#3 NO.ELE.CRACKED&DETER./ OPEN MORTAR JOINTS E
#SR11001CC
DOB VIOLATION - ACTIVE
Apr 25, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2022 EXTERNAL LOW PRESSURE INSPECTION
#03259
DOB VIOLATION - ACTIVE
Apr 25, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2022 EXTERNAL LOW PRESSURE INSPECTION
#03260
DOB VIOLATION - ACTIVE
Apr 22, 2023FAILURE TO SUBMIT EER
FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 - MULTIPLE YEARS (2022)
#00617
DOB VIOLATION - ACTIVE
Feb 15, 2023CONSTRUCTION
FAILURE TO MAINT.BLDG EXTERIOR WALLS FACADE& APPURT.SPALLED STUCCO ON CHIMNEY&FLOWER POTS&OBJECTS ON FIREESCAPES EXP#1&3 SO.&NO.ELEV.SPALLED BRICK ON LANDEN SILL&NUMEROUS STEP CRACKS OBSERVED ON EXP#2 W.ELEV SPALLED STUCCO OPEN MORTAR JOINTS.CRACKED STUCCO&DAMAGED MORTAR JOINTS EXP#4E.ELEV.REMEDY:MA
#SR11001CC
DOB VIOLATION - ACTIVE
Dec 12, 2022CONSTRUCTION
FTM BLDG IN CODE COMPLIANT MANNER. OBSERVED AT EXP1 BROKEN/MISSING PANES AT MULTIPLE LOCATIONS, OBJECTS ON THE FIRE ESCAPES AT MULTIPLE LOCATIONS AND LOOSE PANEL ON THE WINDOW SILL OF THE 4FL. REMEDY: PROVIDE SAFETY MEASURES, REPAIR AND REPLACE
#SR1005AP
DOB VIOLATION - ACTIVE
Dec 1, 2022FAILURE TO POST ENERGY GRADE/SCORE
FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3
#2200485
DOB VIOLATION - ACTIVE
Oct 26, 2022HAZARDOUS CONDITION (FACADE)
CYCLE 9A UNSAFE REPORT FILED
#910516
DOB VIOLATION - ACTIVE
Aug 21, 2022FAILURE TO SUBMIT EER
FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 - MULTIPLE YEARS (2021)
#00282
DOB VIOLATION - ACTIVE
Jun 2, 2022CONSTRUCTION
FTM BUILDING EXTERIOR WALLS FACADE AND APPURTENANCES. OBSERVED EXP1 SOUTH ELEVATION FLOWER POTS AT 4FL FIRE ESCAPE LANDING, CRACKS ON 2FL WINDOW SILL. A/C SUPPORT INADEQUATE AND DAMAGED JOINTS. REMEDY: COMPLY WITH CODE
#LL1004NS
DOB VIOLATION - ACTIVE
Feb 22, 2022NO REPORT AND / OR LATE FILING (FACADE)
FAILED TO FILE FISP CYCLE 9A TECHNICAL REPORT BY 02/21/2022
#00691
DOB VIOLATION - ACTIVE
Dec 1, 2021FAILURE TO POST ENERGY GRADE/SCORE
FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3
#2101085
DOB VIOLATION - ACTIVE
Jun 20, 2021FAILURE TO SUBMIT EER
FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 - MULTIPLE YEARS (2020)
#00362
DOB VIOLATION - ACTIVE
Jun 17, 2021CONSTRUCTION
FTM EXTERIOR FACADE AND APPURTENANCES. EXP 2 WEST ELEVATION CRACK IN MASORNY AT FOURTH FLOOR, DAMAGED MORTAR JOINTS AND SPALLED BRICKS EXPOSURE 3, NORTH ELEVATION. OBSERVED LOOS MORTAR JOINTS SPALLED/ DAMAGED BRICKS AT THIRD AND FOURTH FLOORS. REMEDY: MAINTAIN EXTERIOR BUILDING AND APPURTENANCES
#LLFA02KA
DOB VIOLATION - ACTIVE
Apr 29, 2021FAILURE TO POST ENERGY GRADE/SCORE
FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3
#2001369
DOB VIOLATION - ACTIVE
Feb 2, 2021FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#00162
DOB VIOLATION - ACTIVE
Nov 2, 2020FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#00212
DOB VIOLATION - ACTIVE
Sep 2, 2020FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#01170
DOB VIOLATION - ACTIVE
Aug 2, 2020FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#00425
DOB VIOLATION - ACTIVE
Jun 29, 2020FAILURE TO SUBMIT EER
FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 IN 2019
#10219
DOB VIOLATION - ACTIVE
May 2, 2020FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#00425
DOB VIOLATION - ACTIVE
Apr 3, 2019FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00107
DOB VIOLATION - ACTIVE
Mar 6, 2019FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00112
DOB VIOLATION - ACTIVE
Aug 8, 2016FACADE SAFETY PROGRAM

#HAZ86161
DOB VIOLATION - ACTIVE
Aug 8, 2016FACADE SAFETY PROGRAM

#HAZ76160
DOB VIOLATION - ACTIVE
Mar 3, 2015LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2013 INSPECTION REPORT
#03898
DOB VIOLATION - ACTIVE
Mar 3, 2015LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2013 INSPECTION REPORT
#03897
DOB VIOLATION - ACTIVE
Jun 6, 2014FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#00398
DOB VIOLATION - ACTIVE
May 15, 2014LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT
#02478
DOB VIOLATION - ACTIVE
May 15, 2014LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT
#02477
DOB VIOLATION - ACTIVE
Jan 31, 2013NO REPORT AND / OR LATE FILING (FACADE)
FAILED TO FILE FISP CYCLE 7A TECHNICAL REPORT BY 02/21/2012
#00956
DOB VIOLATION - ACTIVE
Jan 13, 1997LOCAL LAW 10/81 - ELEVATOR

#01700
DOB VIOLATION - ACTIVE
DOB NOW Safety (46)
IssuedViolationStatus
Oct 29, 2026Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2025 Periodic Inspection Affirmation of Correction
Active
Sep 25, 2026Benchmarking - LL84 FTF-EN-BENCH
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
Active
Jun 22, 2026Benchmarking - LL84 FTF-EN-BENCH
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
Active
Mar 6, 2026Benchmarking - LL84 FTF-EN-BENCH
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
Active
Jan 26, 2026Facades FTC-FC-UNSAFE
unsafe report filed
Active
Jan 8, 2026Gas Piping - LL152 FTF-PL-PER
Cycle 2, Sub-cycle A (premises is in Community District 10)
Active
Dec 3, 2025Benchmarking - LL84 FTF-EN-BENCH
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
Active
Nov 14, 2025Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
Active
Nov 14, 2025Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
Active
Oct 10, 2025Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction
Active
Sep 26, 2025Benchmarking - LL84 FTF-EN-BENCH
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
Active
Dec 1, 2024Energy Grade - LL33 FTP-EN-EGRDEA
Active
Oct 11, 2024Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2023 Periodic Inspection Affirmation of Correction
Active
Oct 11, 2024Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2023 Cat1 Test Affirmation of Correction
Active
Sep 23, 2024Boiler LBLVIO
Violation Issued-Failure To File 2023 External Low Pressure Inspection Report
Active
Sep 23, 2024Boiler LBLVIO
Violation Issued-Failure To File 2023 External Low Pressure Inspection Report
Active
Jun 23, 2024Retro-Commissioning - LL87 FTF-EN-EARCX
Active
Jan 3, 2024AEUHAZ FTC-AEU-HAZ
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2018 Cat1 Test Affirmation of Correction
Active
Aug 25, 2023Elevators FTF-VT-PER-CO
Violation Issued-Failure To File 2022 Periodic Inspection Report
Active
Apr 25, 2023Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2022 INSPECTION REPORT
Active
Apr 25, 2023Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2022 INSPECTION REPORT
Active
Apr 22, 2023Retro-Commissioning - LL87 FTF-EN-EARCX
Active
Dec 1, 2022Energy Grade - LL33 FTP-EN-EGRDEA
Active
Oct 26, 2022Facades FISPHAZ
CYCLE 9A UNSAFE REPORT FILED
Active
Aug 21, 2022Retro-Commissioning - LL87 FTF-EN-EARCX
Active
Feb 22, 2022Facades FISPNRF
FAILED TO FILE FISP CYCLE 9A TECHNICAL REPORT BY 02/21/2022
Active
Dec 1, 2021Energy Grade - LL33 FTP-EN-EGRDEA
Active
Jun 20, 2021Retro-Commissioning - LL87 FTF-EN-EARCX
Active
Apr 29, 2021Energy Grade - LL33 FTP-EN-EGRDEA
Active
Feb 2, 2021Benchmarking - LL84 FTF-EN-BENCH
Active
Nov 2, 2020Benchmarking - LL84 FTF-EN-BENCH
Active
Sep 2, 2020AEUHAZ FTC-AEU-HAZ
Active
Aug 2, 2020Benchmarking - LL84 FTF-EN-BENCH
Active
Jun 29, 2020Retro-Commissioning - LL87 FTF-EN-EARCX
Active
May 2, 2020Benchmarking - LL84 FTF-EN-BENCH
Active
Apr 3, 2019AEUHAZ FTC-AEU-HAZ
Active
Mar 6, 2019AEUHAZ FTC-AEU-HAZ
Active
Aug 8, 2016Facades FISP
CYCLE 8A UNSAFE REPORT FILED
Active
Aug 8, 2016Facades FISP
CYCLE 7A UNSAFE REPORT FILED
Active
Mar 3, 2015Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2013 INSPECTION REPORT
Active
Mar 3, 2015Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2013 INSPECTION REPORT
Active
Jun 6, 2014Benchmarking - LL84 FTF-EN-BENCH
Active
May 15, 2014Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT
Active
May 15, 2014Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT
Active
Jan 31, 2013Facades FISPNRF
FAILED TO FILE FISP CYCLE 7A TECHNICAL REPORT BY 02/21/2012
Active
HPD (124) · C 35 · B 69 · A 17
IssuedClassViolationCorrect by
Nov 17, 2025I§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID R—
Mar 11, 2025I§ 27-2142 ADM CODE APTS HAVE BEEN VACATED BY THIS DEPARTMENT AND CANNOT BE REOCCUPIED UNTIL SO ORDERED AFTER PROOF OF COMPLIANCE FOR APTS . 5A, VACATE NUMBER 259344 ON THE 3/11/2025. IN THE ENTIRE APARTMENT LOCATED AT APT, 5th STORY, 2nd APARTMENT FROM WEST AT NORTH—
Jan 31, 2025I§27-2153 ADM CODE THE PREMISES HAS BEEN SELECTED TO PARTICIPATE IN THE ALTERNATIVE ENFORCEMENT PROGRAM WHICH MAY RESULT IN BUILDING-WIDE INSPECTIONS, FEES, AND EXTENSIVE REPAIR WORK TO CORRECT VIOLATIONS AND UNDERLYING CONDITIONS. CHARGES FOR REPAIR WORK DONE PURSUANT TO THIS ORDER, IF NOT PAID, WIL—
Oct 26, 2026CApt 3B · § 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES AT CEILING IN THE 3rd ROOM FROM NORTH LOCATED AT APT 3B, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTHNov 1, 2026
Apr 29, 2026A(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.Aug 2, 2026
Apr 20, 2026CApt 4C · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING AND EAST WALL IN THE 4th ROOM FROM NORTH LOCATED AT APT 4C, 4th STORY, 2nd APARTMENT FROM EAST AT SOUTHApr 26, 2026
Apr 20, 2026CApt 4C · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND EAST WALL IN THE 4th ROOM FROM NORTH LOCATED AT APT 4C, 4th STORY, 2nd APARTMENT FROM EAST AT SOUTHApr 26, 2026
Mar 26, 2026BApt 7C · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT SOUTH WALL IN THE KITCHEN LOCATED AT APT 7C, 7th STORY, 2nd APARTMENT FROM EAST AT SOUTHApr 30, 2026
Mar 26, 2026BApt 7C · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER CEILING IN THE KITCHEN LOCATED AT APT 7C, 7th STORY, 2nd APARTMENT FROM EAST AT SOUTHApr 30, 2026
Mar 26, 2026CApt 7C · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE INOPERABLE HINGES AT DOOR IN THE ENTRANCE LOCATED AT APT 7C, 7th STORY, 2nd APARTMENT FROM EAST AT SOUTHApr 9, 2026
Mar 26, 2026AApt 7C · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES IN THE KITCHEN LOCATED AT APT 7C, 7th STORY, 2nd APARTMENT FROM EAST AT SOUTHJun 29, 2026
Mar 26, 2026BApt 7C · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT NORTH WALL IN THE KITCHEN LOCATED AT APT 7C, 7th STORY, 2nd APARTMENT FROM EAST AT SOUTHApr 30, 2026
Mar 26, 2026BApt 7C · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT EAST WALL IN THE KITCHEN LOCATED AT APT 7C, 7th STORY, 2nd APARTMENT FROM EAST AT SOUTHApr 30, 2026
Jan 30, 2026C§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT HOPPER DOOR AT PUBLIC HALL, 7th STORYFeb 13, 2026
Dec 10, 2025CApt 7C · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) CEILING IN THE 4th ROOM FROM NORTH LOCATED AT APT 7C, 7th STORY, 2nd APARTMENT FROM EAST AT SOUTHJan 3, 2026
Dec 10, 2025CApt 7C · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) CEILING IN THE KITCHEN LOCATED AT APT 7C, 7th STORY, 2nd APARTMENT FROM EAST AT SOUTHJan 3, 2026
Dec 2, 2025BApt 7C · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE KITCHEN LOCATED AT APT 7C, 7th STORY, 2nd APARTMENT FROM EAST AT SOUTHJan 6, 2026
Dec 2, 2025BApt 7C · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT THE CEILING IN THE KITCHEN LOCATED AT APT 7C, 7th STORY, 2nd APARTMENT FROM EAST AT SOUTHJan 6, 2026
Dec 2, 2025BApt 7C · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT THE CEILNG IN THE 4th ROOM FROM NORTH LOCATED AT APT 7C, 7th STORY, 2nd APARTMENT FROM EAST AT SOUTHJan 6, 2026
Dec 2, 2025CApt 7C · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE COLD RADIATOR IN THE 1st ROOM FROM NORTH LOCATED AT APT 7C, 7th STORY, 2nd APARTMENT FROM EAST AT SOUTHDec 8, 2025
Dec 2, 2025CApt 7C · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE APARTMENT DOOR HINGES IN THE ENTRANCE LOCATED AT APT 7C, 7th STORY, 2nd APARTMENT FROM EAST AT SOUTHDec 16, 2025
Dec 2, 2025BApt 7C · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE 4th ROOM FROM NORTH LOCATED AT APT 7C, 7th STORY, 2nd APARTMENT FROM EAST AT SOUTHJan 6, 2026
Dec 1, 2025CApt 6G · § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING MORTISE LOCK ON DOOR IN THE ENTRANCE LOCATED AT APT 6G, 6th STORY, 3rd APARTMENT FROM WEST AT NORTHDec 7, 2025
Dec 1, 2025C§ 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES AT CEILING AT EAST SECTION AT PUBLIC HALLDec 7, 2025
Dec 1, 2025CApt 6G · § 27-2026 ADM CODE REPLACE THE BROKEN OR DEFECTIVE BATHTUB IN THE BATHROOM LOCATED AT APT 6G, 6th STORY, 3rd APARTMENT FROM WEST AT NORTHDec 7, 2025
Dec 1, 2025CApt 6G · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 6G, 6th STORY, 3rd APARTMENT FROM WEST AT NORTHDec 27, 2025
Nov 18, 2025CApt 7C · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 7C, 7th STORY, 2nd APARTMENT FROM EAST AT SOUTHDec 14, 2025
Nov 18, 2025CApt 7C · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE INOPERABLE HINGES IN THE ENTIRE APARTMENT LOCATED AT APT 7C, 7th STORY, 2nd APARTMENT FROM EAST AT SOUTHDec 2, 2025
Nov 18, 2025BApt 7C · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER THE CEILING IN THE KITCHEN LOCATED AT APT 7C, 7th STORY, 2nd APARTMENT FROM EAST AT SOUTHDec 23, 2025
Aug 13, 2025B§ 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. ADJUST THE DROPLADDER SO THAT IT WILL SLIDE EASILY IN THE GUIDE RODS AT REAR YARDSep 17, 2025
Aug 13, 2025C§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF DROP LADDER TOO CLOSE TO FENCE AT FRONT YARD AT FIRE ESCAPEAug 19, 2025
Aug 13, 2025B§ 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. ADJUST THE DROPLADDER SO THAT IT WILL SLIDE EASILY IN THE GUIDE RODS AT FRONT YARD AT FIRE ESCAPESep 17, 2025
Jul 14, 2025BApt 7E · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT SOUTH WALL IN THE 5th ROOM FROM NORTH LOCATED AT APT 7E, 7th STORY, 4th APARTMENT FROM EAST AT SOUTHAug 18, 2025
Jul 14, 2025CApt 7E · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LOCKSET MECHANISM IN THE ENTRANCE LOCATED AT APT 7E, 7th STORY, 4th APARTMENT FROM EAST AT SOUTHJul 20, 2025
Jul 9, 2025CApt 5H · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LOCKSET IN THE ENTRANCE LOCATED AT APT 5H, 5th STORY, 1st APARTMENT FROM WEST AT NORTHJul 15, 2025
Jun 17, 2025AApt 2B · § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING DOOR KNOB AT CLOSET DOORS IN THE PRIVATE HALLWAY LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTHSep 20, 2025
Jun 17, 2025AApt 2B · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE CLOSET DOOR HINGES IN THE PRIVATE HALLWAY LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTHSep 20, 2025
Jun 17, 2025AApt 2B · § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING CLOSET DOOR IN THE 4th ROOM FROM NORTH LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTHSep 20, 2025
Jun 17, 2025AApt 2B · § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING DOOR KNOB AT CLOSET IN THE 6th ROOM FROM NORTH AT EAST LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTHSep 20, 2025
Jun 17, 2025CApt 2B · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTHJul 13, 2025
Jun 17, 2025BApt 2B · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR NORTH WALL AT SINK BASE CABINET IN THE KITCHEN LOCATED AT APT 2B, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTHJul 22, 2025
Jun 3, 2025CApt 6B · § 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN WASTEPIPE AT WASH BASIN IN THE 2nd BATHROOM LOCATED AT APT 6B, 6th STORY, 1st APARTMENT FROM EAST AT SOUTHJun 9, 2025
Jun 3, 2025CApt 6B · § 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN WASTEPIPE AT WATERCLOSET IN THE 1st BATHROOM LOCATED AT APT 6B, 6th STORY, 1st APARTMENT FROM EAST AT SOUTHJun 9, 2025
Jun 3, 2025BApt 6B · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE ENRTY DOOR IN THE 4th ROOM FROM NORTH LOCATED AT APT 6B, 6th STORY, 1st APARTMENT FROM EAST AT SOUTHJul 8, 2025
Jun 2, 2025CApt 7E · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQUARE FEET AT CEILING IN THE BATHROOM LOCATED AT APT 7E, 7th STORY, 5th APARTMENT FROM EAST AT SOUTH ORIGINAL VIOLATION 17373431 ISSUED 24-OCT-24 HAS BEEN UPGRADED TO CLASS C PER ADMINISTRATIVE CODE §2Jun 28, 2025
May 23, 2025C§ 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) THROUGHOUT THE PUBLIC AREAS IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12.Jun 18, 2025
Apr 10, 2025C§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT HOPPER DOOR AT PUBLIC HALL, 4th STORYApr 24, 2025
Mar 13, 2025B§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES AT PUBLIC HALL, 1st STORY, SECTION ''EAST''Apr 17, 2025
Mar 6, 2025CApt 5A · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF FIRE DAMAGE IN THE ENTIRE APARTMENT LOCATED AT APT 5A, 5th STORY, 2nd APARTMENT FROM WEST AT NORTHMar 12, 2025
Mar 5, 2025BApt 3A · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE FOYER LOCATED AT APT 3A, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTHApr 9, 2025
Mar 5, 2025BApt 3A · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEVICE DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 3A, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTHApr 9, 2025
Mar 5, 2025BApt 3A · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE BATHROOM LOCATED AT APT 3A, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTHApr 9, 2025
Mar 5, 2025BApt 3A · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 1st ROOM FROM EAST LOCATED AT APT 3A, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTHApr 9, 2025
Mar 5, 2025BApt 3A · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE SOUTH WALL IN THE 1st ROOM FROM EAST LOCATED AT APT 3A, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTHApr 9, 2025
Mar 5, 2025BApt 3A · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE PRIVATE HALLWAY LOCATED AT APT 3A, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTHApr 9, 2025
Mar 5, 2025BApt 3A · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEVICE DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 3A, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTHApr 9, 2025
Mar 5, 2025BApt 3A · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE FOYER LOCATED AT APT 3A, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTHApr 9, 2025
Feb 28, 2025BApt 3A · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR. IN THE 1st ROOM FROM EAST LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION AT EASTApr 4, 2025
Feb 28, 2025BApt 3A · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT THE CEILING AND SOUTH WALL IN THE 1st ROOM FROM EAST LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION AT EASTApr 4, 2025
Feb 28, 2025BApt 2A · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 3rd ROOM FROM EAST LOCATED AT APT 2A, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION AT EASTApr 4, 2025

Showing 60 of 124. Full list on the agency site.

Issued in the last 120 days

DateSourceWhatNow
Oct 29, 2026DOB SafetyElevators: Violation Issued-Failure To File 2025 Periodic Inspection Affirmation of CorrectionOpen
Oct 26, 2026HPD C§ 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES AT CEILING IN THE 3rd ROOM FROM NORTH LOCATED AT APT 3B, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTHOpen
Sep 25, 2026DOB SafetyBenchmarking - LL84: FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4Open

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 3, 2026, 9:35 AM ET. BBL 1020090012.

Look up another building