6 floors · 40 apartments · 26,892 sq ft · built 1903 · class C7 · owner of record: 202-206 Thompson St. Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 70 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 70 days | Annual |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-08-22 (Accepted). Agency page | Dec 31, 2026 in 70 days | 1 of 1 without an accepted 2026 report yet |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 86 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 26,892 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 191 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 191 days | Annual filing |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 314 days | Registered through 2027-09-01 |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 2 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1166 days | Next cycle year 2029 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| May 5, 2026 | Construction CLASS - 2 AT 4:20AM OBSERVED 6 STORY BUILDING WITH SIDEWALK SHED INSTALLED AT EXP# 1 4 THAT WAS INADEQUATELY ILLUMINATED (NOTE NO BULBS LIT) AS STIPULATED IN BC3307.6.4.8 CREATES HAZARDOUS CONDITIONS FOR PEDESTRIANS OF S #39553788H | Nov 5, 2026 | $2,400 |
| Apr 23, 2026 | Construction CLASS - 2 PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATIONS.AT TIME OF INSPECTION,I OBSERVED SIDEWALK SHEDS IN PLACE AT EXPOSURE#1 AND EXPOSURE#4,MISSING CAPS FROM THE BOLTS.THIS CREATES SHARP EDGES.CAUSING HAZARDO #39553343P | Jul 2, 2026 IN VIOLATION | $2,400 |
| Mar 11, 2026 | Unknown CLASS - 1 NOTE: AT TIME OF INSPECTION, I OBSERVED A SUPPORTED PIPE SCAFFOLD IN PLACE, AT EXPOSURES#1-4 THE DEBRIS NETTING WAS NOT SECURELY ATTACHED TO THE SCAFFOLD AT MULTIPLE LOCATIONS AS REQUIRED BY CODE (3314.8.2). TH #39551509R | Jan 21, 2027 PENDING | $5,000 |
| Dec 16, 2024 | Construction CLASS - 2 AT TIME OF INSPECTION I OBSERVED SIDEWALK SHED IN PLACE AT EXPOSURE # 1 AND 2 WITHOUT OPERABLE LIGHTING BULBS UNDERSIDE OF SIDEWALK SHED AS REQUIRED BY THE CODE, THIS CREATE UNSAFE CONDITION FOR PEDESTRIANBY P #39535191X | Feb 20, 2025 IN VIOLATION | $2,400 |
| Mar 3, 2021 | Construction CLASS - 1 WORK WITHOUT A PERMIT. WORK NOTED AT 1ST FLOOR EXPOSURE 1 ON THOMPSON STREET, INSTALLED ELECTRICAL WIRING TO SUPPLY 4 HEATING UNITS AND LIGHTING FOR OUTDOOR DINING STRUCTURE. REMEDY: OBTAIN PERMIT #35499039K | May 20, 2021 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| May 26, 2021 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00151 | DOB VIOLATION - ACTIVE |
| Apr 29, 2021 | FAILURE TO POST ENERGY GRADE/SCORE FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3 #2000231 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Jul 30, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Sep 18, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle B (premises is in Community District 2) | Active |
| May 26, 2021 | AEUHAZ FTC-AEU-HAZ | Active |
| Apr 29, 2021 | Energy Grade - LL33 FTP-EN-EGRDEA | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Dec 16, 2021 | C | Apt 13 · § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 13, 6th STORY, 1st APARTMENT FROM NORTH AT EAST | Dec 16, 2021 |
| Dec 16, 2021 | C | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM GRATE DOORS LOCKED AT FRONT YARD | Dec 22, 2021 |
| Dec 16, 2021 | C | § 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM MISSING | Dec 22, 2021 |
| Dec 16, 2021 | A | § 27-2053 ADM CODE POST SIGN ON WALL OF ENTRANCE STORY BEARING NAME, ADDRESS INCLUDING APARTMENT NUMBER IF ANY, AND TELEPHONE NUMBER OF SUPERINTENDENT, JANITOR OR HOUSEKEEPER. | Mar 21, 2022 |
| Dec 9, 2021 | C | Apt 12 · § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE , IN THE ENTRANCE LOCATED AT APT 12, 5th STORY, 1st APARTMENT FROM WEST AT NORTH | Jan 4, 2022 |
| Dec 9, 2021 | C | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BOILER ROOM | Dec 15, 2021 |
| Dec 9, 2021 | B | Apt 12 · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 12, 5th STORY, 1st APARTMENT FROM WEST AT NORTH | Jan 13, 2022 |
| Mar 22, 2010 | B | § 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSEHOLD ITEMS AT INTERMEIDATE LANDING ,6TH PUBLIC HALL STAIRS | May 26, 2010 |
| Mar 22, 2010 | B | Apt 23 · § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE ... IN THE ENTRANCE LOCATED AT APT 23, 6th STORY, 1st APARTMENT FROM NORTH AT EAST | May 26, 2010 |
| Mar 22, 2010 | B | Apt 23 · § 27-2026 ADM CODE REPAIR THE FLUSHING APPARATUS AND MAINTAIN SAME SO AS TO FLUSH EFFECTIVELY THE WATER CLOSET DEFECTIVE FLUSHOMETER AT WATER CLOSET. IN THE BATHROOM LOCATED AT APT 23, 6th STORY, 1st APARTMENT FROM NORTH AT EAST | May 26, 2010 |
| Mar 22, 2010 | B | § 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSEHOLD ITEMS AT BULKHEAD LANDING | May 26, 2010 |
| Mar 22, 2010 | B | Apt 23 · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC WALL TILES AT NORTH WALL IN THE BATHROOM LOCATED AT APT 23, 6th STORY, 1st APARTMENT FROM NORTH AT EAST | May 26, 2010 |
| Mar 22, 2010 | B | Apt 23 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT NORTH WAL IN THE BATHROOM LOCATED AT APT 23, 6th STORY, 1st APARTMENT FROM NORTH AT EAST | May 26, 2010 |
| Mar 22, 2010 | B | Apt 23 · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES IN THE KITCHEN LOCATED AT APT 23, 6th STORY, 1st APARTMENT FROM NORTH AT EAST | May 26, 2010 |
| Mar 22, 2010 | B | Apt 23 · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 23, 6th STORY, 1st APARTMENT FROM NORTH AT EAST | Apr 26, 2010 |
| Mar 22, 2010 | B | Apt 23 · § 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 23, 6th STORY, 1st APARTMENT FROM NORTH AT EAST | Apr 26, 2010 |
| Aug 18, 2008 | A | § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION WOOD ENCLOSURE CREATED FOR RESTURANT APPROX 6 20 OBSTRUTING EGRESS FROM FIRE ESCAPE AT SOUTH ER1. | Nov 21, 2008 |
| Aug 13, 2007 | B | § 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF HOUSEHOLD ITEMS AT FLOOR.. AT PUBLIC HALL, 1st STORY | Sep 17, 2007 |
| Date | Source | What | Now |
|---|---|---|---|
| Jul 30, 2026 | DOB Safety | AEUHAZ: | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 22, 2026, 5:53 PM ET. BBL 1005370037.