5 floors · 149,000 sq ft · built 1939 · class G1 · owner of record: Ppc Commercial, Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 9 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 62 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 62 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 149,000 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 183 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 183 days | Annual filing |
| Energy audit and retro-commissioning (2033) Likely applies Local Law 87 · Calendar year 2033 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 3943). Agency page | Dec 31, 2033 in 2619 days | Next due 2033 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Jun 18, 2024 | Construction CLASS - 2 EXP1 SCAFFOLD WITH DEBRIS CHUTE NOT CONFORMING TO PE DRAWINGS PROVIDED WHICH INDICATES 2 INCH PIPE BRACE AGAINST CHUTE,GC FAILED PROVIDE MANUFACTURE SPECS FOR CHUTE UPON REQUEST CREATING HAZARD OF EQUIPMENT FAI #39529784K | Aug 30, 2024 DEFAULT | $0 |
| Mar 23, 2024 | Unknown CLASS - 2 FAILURE TO PROVIDE SAFE STORAGE AREA ON CONSTRUCTION SITE NEAR PEDESTRIAN WALKWAYS. AT TIME OF INSPECTION OBSERVED CONSTRUCTION MATERIALS WITHOUT PROPER SOLID FENCE OR BARRIER. ALSO OBSERVED A DEBRIS CHUTE SUSP #35588236Y | Jul 5, 2024 ADMIT/IN-VIO | $0 |
| Mar 23, 2024 | Unknown CLASS - 2 AT TIME OF INSPECTION OBSERVED SUPPORTED SCAFFOLD INSTALLED AT ALL EXPOSURES. SUPPORTED SCAFFOLDS NOT MAINTAINED IN CODE COMPLYING MANNER. SAFETY NETTING IS DETACHED FROM FROM FRAMES FROM TOP ALL THE WAY TO BAS #35588235M | Jul 5, 2024 ADMIT/IN-VIO | $0 |
| Oct 17, 2023 | Elevators CLASS - 1 CEASE USE NOT LIFTED . RECURRING CONDITION #39097273M | Dec 29, 2023 ADMIT/IN-VIO | $0 |
| Oct 11, 2023 | Construction CLASS - 1 FAILURE TO COMPLY WITH COMMISSIONER'S ORDER IN DOB VIOLATION VIO23-01330,DATED 5/8/23.RESPONDENT WAS REQUIRED TO SUBMIT AN ENGINEER'S REPORT CONCERNING STRUCTURALLY DEFICIENT CONDITIONS.AS OF 10/11/23 AN ENGINE #37025588L | Aug 2, 2024 IN VIOLATION | $2,500 |
| Jun 16, 2023 | Elevators CLASS - 2 RESPONDING TO 311 ELEVATOR COMPLAINT UPON INSPECTION OF DEVICE, DEVICE WAS FOUND OUT -OF- SERVICE WITH EXPIRED WORK PERMIT , CLASS 2 VIOLATION WAS ISSUED FOR FAILED TO OBTAIN CERTIFICATE OF COMPLETION FOR FOR P #39088907K | Sep 1, 2023 DEFAULT | $0 |
| May 8, 2023 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER: OBSERVED AT PARKING GARAGE SOUTH STAIRWELL BETWEEN 2ND- 3RD FLOOR LEVELS, HANDRAIL DISCONNECTED FROM POST AT LAST STEP BEFORE LANDING., REPAIR AND/OR REPLA #39085758M | Jul 21, 2023 DEFAULT | $3,125 |
| May 8, 2023 | Construction CLASS - 1 OBSERVED AT PARKING GARAGE. SEVERAL CRACKS IN CMU WALLS AT BOTH NORTH & SOUTH STAIRWELLS, MULTIPLE CRACKED CONCRETE BEAMS. AT 5TH FLOOR LEVEL, MISSING CONCRETE AT CEILING SLAB EXPOSING REBAR &WIRE MESH. AT ROOF #39085757K | Jul 21, 2023 DEFAULT | $6,250 |
| Nov 4, 2022 | Construction CLASS - 2 AT THE TIME OF INSPECTION OBSERVED INACTIVE 5 STORY ALTERATION WORK SITE. CLASS 1 VIOLATION #39505662X WAS ISSUED ON 08.26.2022 AND CERTIFICATE OF CORRECTION WAS NOT FILED ON DOB SYSTEM. G.C FAILED TO COMPLY W #39508822J | Apr 24, 2023 IN VIOLATION | $0 |
| Nov 4, 2022 | Construction CLASS - 2 AT THE TIME OF INSPECTION OBSERVED INACTIVE 5 STORY ALTERATION WORK SITE. CLASS 1 VIOLATION #39505660M WAS ISSUED ON 08.26.2022 AND CERTIFICATE OF CORRECTION WAS NOT FILED ON DOB SYSTEM. G.C FAILED TO COMPLY W #39508821H | Apr 24, 2023 IN VIOLATION | $0 |
| Sep 20, 2022 | Construction CLASS - 2 IN RESPONDS TO COMPLAINT AND AT THE TIME OF INSPECTION OF A EXISTING OCCUPIED 5 STORY BUILDING CURRENTLY UNDER ALTERATION, I OBSERVED INSTALLED SWS IN PLACES ON PEDESTRIAN WALKWAYS WITH NO ILLUMINATION AS PER S #39506518X | Nov 4, 2022 IN VIOLATION | $0 |
| Aug 26, 2022 | Construction CLASS - 1 NOTE: AT THE TIME OF PARAPET COLLAPSED INCIDENT FOLLOW UP INSPECTION OBSERVED CONCERT SLAB, BEAM DEMOLITION WORK IN PROGRESS USING EXCAVATOR ON ROOF LEVEL ON A 5STY GARAGE BUILDING HAVE NO PERMIT/PLAN FOR MECH #39505641R | Mar 10, 2023 IN VIOLATION | $0 |
| Aug 3, 2022 | Elevators CLASS - 1 97X17: 97-X-17 CLASS 1 RESTORE TO SERVICE REPAIR ELEVATOR & RESTORE TOSERVICE IMMEDIATELY CALL NYC DEPARTMENT OF BUILDINGS ELEVATOR DIVISION& EMAIL ELEVATORIR@BUILDINGS.NYC.GOV #38274485M | Nov 4, 2022 ADMIT/IN-VIO | $0 |
| Apr 9, 2022 | Elevators CLASS - 1 RECURRING, CLASS 1, RTS. UPON INSPECTION OF THE DEVICE IS FOUND TO BE OUT-OF-SERVICE,AS PER 1RCNY 11-02. REMEDY; RESTORE TO SERVICE IMMEDIATELY AND. NOTIFY NYCDOB THE DEVICE HAS BEEN RETURNED TO SERVICE. E-MAIL #39060238H | Jul 29, 2022 ADMIT/IN-VIO | $0 |
| Apr 5, 2022 | Construction CLASS - 2 PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATION.NOTE AT TIME OFINSPECTION I OBSERVED SIDEWALK SHED IN PLACE WITH LIGHTS NOT IN OPERATING CONDITION AT EXPOSURE#3.REM:COMPLY WITH CODE-PROVIDE LIGHTING DUSK #35646032P | Jul 1, 2022 DEFAULT | $5,000 |
| Feb 2, 2022 | Elevators CLASS - 1 UPON INSPECTION DEVICE WAS FOUND OUT OF SERVICE. THIS IS THE ONLY ELEVATOR IN THE BUILDING. RESTORE TO SERVICE IMMEDIATELY . YOU CAN CONTACT NYCDOB AT EIR@BUILDINGS.NYC.GOV FOR A COMPLETE INSPECTION. #39055452M | Jul 22, 2022 ADMIT/IN-VIO | $0 |
| Dec 6, 2021 | Elevators CLASS - 1 RESTORE TO SERVICE #39052321Z | Jan 21, 2022 IN VIOLATION | $0 |
| Sep 1, 2021 | Elevators CLASS - 1 CLASS 1 VIOLATION ISSUED, RTS UPON INSPECTION DEVICE IS STILL UNDER CEASE USE ORDER, COMPLY WITH CEASE USE ORDER AND NOTIFY NYCDOB FOR RESTORE TO SERVICE REINSPECTION #39046969K | May 6, 2022 ADMIT/IN-VIO | $0 |
| May 28, 2021 | Elevators CLASS - 1 RESTORE DEVICE TO SERVICE SO THAT INSPECTION CAN BE MADE BY THIS DEPARTMENT. #39042009P | Sep 3, 2021 ADMIT/IN-VIO | $0 |
| Jan 15, 2021 | Elevators CLASS - 1 RESTORE DEVICE TO SERVICE. PERFORM CAT 5 TEST. PROVIDE SERVICE STICKER ON MAIN LINE. PROVIDE GOVERNOR OVERSPEED SWITCH. NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS PER 3.10.12 OF APPENDIX K3 OF THE #39034981P | Apr 16, 2021 ADMIT/IN-VIO | $0 |
| Dec 2, 2020 | Elevators CLASS - 1 97-X-17= CLASS 1 RTS REPAIR ELEVATOR & RESTORE TO SERVICE CALL NYC DEPT OF BUILDING ELEVATOR DIVISION FOR REINSPECION #38273670J | Mar 19, 2021 IN VIOLATION | $0 |
| Oct 20, 2020 | Elevators CLASS - 1 RESTORE DEVICE TO SERVICE. PERFORM CAT 5 TEST. PROVIDE SERVICE STICKER ON MAIN LINE. PROVIDE GOVERNOR OVERSPEED SWITCH. NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS PER 3.10.12 OF APPENDIX K3 OF THE #39030650M | Dec 4, 2020 IN VIOLATION | $0 |
| Aug 6, 2020 | Elevators CLASS - 1 CLASS 1 NO DOOR LOCK MONITORING IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC. REMEDY; FILE APPLICATION, INSTALL DLM AND PERFORM AND FILE TEST WITH NYCDOB. EXP 1 YEAR TAG, EXP 5 YEA #39026512M | Oct 2, 2020 DEFAULT | $0 |
| Mar 25, 2020 | Elevators CLASS - 1 RESTORE TO SERVICE NO ACCESS TO MOTOR ROOM #39020424P | Jan 15, 2021 IN VIOLATION | $0 |
| Feb 29, 2020 | Elevators CLASS - 1 CEASE USE, 2) ITEM, NO GOVERNOR ELECTRIC SAFETY SWITCH, / FIVE YEAR TEST TAG EXP, REMEDY; PROVIDE AND INSTALL AND (TAC) IN THE PRESENCE OF A DOB ELEVATOR INSPECTOR, 2) PERFORM & FILE TEST. CLASS 1, NO DOOR LOCK #39018619M | Aug 28, 2020 DEFAULT | $0 |
| Jan 16, 2019 | Elevators CLASS - 1 16T15,98BB5,99BB5,68U7,59X5 #38266434M | Jul 26, 2019 DEFAULT | $0 |
| Jul 23, 2018 | Elevators CLASS - 2 28H11,16N10,71X10,12X10. (16N)ELEV BY PASS 3RD FLOOR - 5TH FLOOR DOOR DOES NOT OPEN. (28H)HANGER ROLLERS WORN. #38261936J | Sep 7, 2018 DEFAULT | $0 |
| Jan 17, 2018 | Elevators CLASS - 1 CU05A10,05J01; 68B07,98BB05,59M07,69M07,41I10,57BB11,02X10,71X10,03D06. 05A-ZONE LOCK ARM MISSING/RENDERED INOPERATIVE. THIS ENSURES SAFETY OF PASSENGERS. 05J-ADJUST GAP RETURN SIDE CA DOOR; EMAIL:EIR@BUILDIN #38259322M | Mar 30, 2018 IN VIOLATION | $0 |
| Feb 27, 2017 | Elevators CLASS - 2 32H11,34O02,16L10,40P07. 16-HOISTWAY DOORS NOT OPENING PROPERLY ON THE 5TH FLOOR AND 4TH FLOOR. #38253476H | Apr 21, 2017 DEFAULT | $0 |
| Issued | Violation | Status |
|---|---|---|
| Aug 21, 2024 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00082 | DOB VIOLATION - ACTIVE |
| Oct 31, 2023 | CONSTRUCTION CRCKS & SPALLS OBSRVED IN CONC BEAMS, COLS, & SLABS. PART DEMO OF ROOF SLAB & BEAMS, PARTIALLY REMOVED ROOF PARAPET, CRCKS ON BRCK ROOF TOWER REMEDY: COMPLY W CODE & MANDATE2COMPLTE WRK UNDER PERMIT.WRK2COMMNCE BY 11/13/ 23. PRVIDE COMP UPDATE.S/S CERT ONCE WRK IS COMPLETE #CE20901YU | DOB VIOLATION - ACTIVE |
| Oct 4, 2023 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #01280 | DOB VIOLATION - ACTIVE |
| Jun 30, 2023 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00120 | DOB VIOLATION - ACTIVE |
| Jun 30, 2023 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00121 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Oct 10, 2025 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2024 Periodic Inspection Affirmation of Correction | Active |
| Aug 29, 2025 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2024 Cat1 Test Report | Active |
| Oct 11, 2024 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2023 Periodic Inspection Affirmation of Correction | Active |
| Aug 21, 2024 | AEUHAZ FTC-AEU-HAZ | Active |
| Oct 4, 2023 | AEUHAZ FTC-AEU-HAZ | Active |
| Aug 25, 2023 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2022 Periodic Inspection Report | Active |
| Aug 11, 2023 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2020 Cat1 Test Report | Active |
| Aug 11, 2023 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2019 Cat1 Test Report | Active |
| Aug 11, 2023 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2018 Cat1 Test Report | Active |
| Aug 11, 2023 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2021 Cat1 Test Report | Active |
| Aug 11, 2023 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Report | Active |
| Jun 30, 2023 | AEUHAZ FTC-AEU-HAZ | Active |
| Jun 30, 2023 | AEUHAZ FTC-AEU-HAZ | Active |
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 30, 2026, 5:03 AM ET. BBL 2039430001.