Brooklyn · Block 1328 · Lot 16 · 11225

150 Lefferts Avenue

6 floors · 53 apartments · 48,834 sq ft · built 1939 · class D1 · owner of record: 150 Lefferts Avenuecompany Llc

345open violations
$43,179ECB/OATH penalties owed
123HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueRegistration expired 2026-09-01
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 9 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 66 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 66 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 66 days
Annual
Annual boiler inspection (2 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-12-18 (Accepted). Agency page

Dec 31, 2026
in 66 days
2 of 2 without an accepted 2026 report yet
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 82 days
Annual
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 48,834 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 187 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 187 days
Annual filing

Open violations

ECB / OATH (27) · $43,179 owed
IssuedViolationHearingBalance
Jun 25, 2026Construction CLASS - 2
AT TIME OF INSPECTION OBSERVED: SIDEWALK SHED INSTALLED AT EXPO# 1 MISSING PROJECT INFORMATION PANEL CONTRARY TO BC 3301.9.2. CREATING UNSAFE CONDITIONS FOR PUBLIC AND OCCUPIED ADJOINING PROPERTIES, SAFETY MONI
#39555866N
Sep 2, 2026
DEFAULT
$1,280
Jun 25, 2026Unknown CLASS - 2
AT TIME OF INSPECTION OBSERVED: SIDEWALK SHED IN PLACE AT EXPO# 1 ON EXISTING 6 STORY MULTIPLE DWELLING OCCUPIED BUILDING. UPON REVIEWING DEPARTMENT OF RECORDS, IT APPEARS NO SIDEWALK SHED PERMIT HAS YET BEEN I
#39555865L
Sep 2, 2026
DEFAULT
$1,280
Apr 20, 2026Unknown CLASS - 2
AT HE TIME OF MY INSPECTION OF A 6 STORY BUILDING, I OBSERVED SIDEWALK SHED IN PLACE AT EXPOSURE #1, UPON REVIEW OF THE DEPARTMENT RECORD IT REVEAL THAT THERE IS NO VALID SIDEWALK SHED PERMIT. FAILURE TO OBTAIN
#39553217Y
Jun 24, 2026
DEFAULT
$6,250
Mar 16, 2026Construction CLASS - 2
AT HE TIME OF MY INSPECTION OF A 6 STORY BUILDING, I OBSERVED SIDEWALK SHED IN PLACE AT EXPOSURE #1 WITH MISSING BOLT COVERS IN VARIOUS PLACES AND DEBRIS SAFETY NETTING LOOSED ALL THE WAY AROUND SIDEWALK SHED,
#39551803H
Jan 4, 2027
PENDING
$2,400
Mar 16, 2026Unknown CLASS - 2
AT HE TIME OF MY INSPECTION OF A 6 STORY BUILDING, I OBSERVED SIDEWALK SHED IN PLACE AT EXPOSURE #1, UPON REVIEW OF THE DEPARTMENT RECORD IT REVEAL THAT SIDEWALK SHED PERMIT NOT YET ISSUED. FAILURE TO OBTAIN SI
#39551802X
Jan 4, 2027
PENDING
$1,250
Oct 16, 2025Unknown CLASS - 2
AT THE TIME OF INSPECTION, A SIDEWALK SHED WAS OBSERVED TO BE INSTALLED AT THE PREMISES. UPON REVIEWING DEPARTMENT RECORDS, IT WAS DETERMINED THAT THERE IS NO VALID PERMIT ON FILE FOR THE INSTALLED SIDEWALK SHE
#39546041Y
Jul 23, 2026
IN VIOLATION
$1,250
Aug 28, 2025Elevators CLASS - 1
ONLY ELEVATOR IN A MULTIPLE DWELLING OUT OF SERVICE. THIS CONDITION AFFECTS NUMEROUS TENANTS, INCLUDING THOSE WITH SPECIAL NEEDS, THEREBY CREATING A CONDITION DANGEROUS TO HUMAN LIFE.
#39158631J
Nov 12, 2025
IN VIOLATION
$1,250
Jul 30, 2025Elevators CLASS - 1
RESTORE SERVICE TO DEVICE. DEVICE FAILED REINSPECTION. MAKE ALL NECESSARY REPAIRS AND CONTACT THIS DEPARTMENT IN ORDER TO SCHEDULE A REINSPECTION.
#39155400Z
Oct 8, 2025
IN VIOLATION
$1,250
Jul 21, 2025Elevators CLASS - 1
: FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. A PREVIOUSLY ISSUED CEASE USE ORDER REMAINS IN EFFECT. UPON INSPECTION, THE DEVICE IS FOUND TO BE OUT OF SERVICE. REMEDY: REPAIR THE CEASE USE ITEMS, RES
#39154269H
Oct 1, 2025
IN VIOLATION
$3,125
Apr 29, 2025Elevators CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. A PREVIOUSLY ISSUED CEASE USE ORDER REMAINS IN EFFECT. UPON INSPECTION, THE DEVICE IS FOUND TO BE OUT OF SERVICE. REMEDY: REPAIR THE CEASE USE ITEMS, RESTO
#39146469M
Jul 9, 2025
IN VIOLATION
$6,250
Apr 9, 2025Elevators CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. A PREVIOUSLY ISSUED CEASE USE ORDER REMAINS IN EFFECT. UPON INSPECTION, THE DEVICE IS FOUND TO BE OUT OF SERVICE. REMEDY: REPAIR THE CEASE USE ITEMS, RESTO
#39144390K
Jun 18, 2025
IN VIOLATION
$1,250
Mar 18, 2025Elevators CLASS - 1
CEASE USE ITEMS: NO RECORD OF CATEGORY 5 TEST BEING PERFORMED AND ACCEPTED BY THIS DEPARTMENT. REMEDY: FILE AND PERFORM A FULL AND COMPLETE CATEGORY 5 TEST IN THE PRESENCE OF AN INSPECTOR FROM THIS DEPARTMENT.
#39141976Y
May 28, 2025
IN VIOLATION
$1,250
Nov 14, 2024Elevators CLASS - 1
NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC. THIS IS A CONTROLLER FEATURE WHICH ENSURES PASSENGER SAFETY. REMEDY; FILE APPLICATION, INSTALL DLM A
#39130219N
Jan 22, 2025
DEFAULT
$3,125
May 20, 2024Unknown CLASS - 2
ATOI OBSERVED SIDAWALK SHED BUILT ON EXP 1 OF THE 6 STORY BUILDING. AS PER DOB FILE NO PERMIT WAS ISSUED, OBTAIN A PERMIT
#39114843R
Jun 5, 2025
IN VIOLATION
$3,125
Jan 12, 2024Unknown CLASS - 2
AT THE TIME OF MY INSPECTION OF A 6 STORY BUILDING, I OBSERVED SIDEWALK SHED IN PLACE AT EXPOSURE #1 UPON REVIEW OF THE DEPARTMENT RECORDS IT REVEAL THAT THERE WERE NO WORK PERMIT APPLIED FOR OR ISSUED, THIS CR
#39524814J
Apr 17, 2024
IN VIOLATION
$1,250
Jan 12, 2024Unknown CLASS - 2
AT THE TIME OF MY INSPECTION OF A 6 STORY BUILDING, I OBSERVED SIDEWALK SHED IN PLACE AT EXPOSURE #1 EXTENDED APPROXIMATELY 6 FEET OVER ADJOINING PROPERTY AT 146 LEFFERTS AVENUE AND THERE WERE NO ACCESS AGREEME
#39524772K
Apr 17, 2024
IN VIOLATION
$2,500
Nov 29, 2023Elevators CLASS - 1
CLASS 1 ITEM: NO DOOR LOCK MONITORING INSTALLED ON THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 OF THE 2014 NYC BUILDING CODE. THIS IS A FEATURE WHICH ENSURES PASSENGER SAFETY. FILE APPLICATION; INSTAL
#39100316H
Jun 23, 2025
IN VIOLATION
$3,125
Oct 31, 2023Construction CLASS - 1
AT TIME OF INSPECTION OBSERVED FACADE AT EXP#1 2 AND 4 IN STATE OF DISREPAIR. AT EXP#1 AND 2 FACADE HAVE CRACKS. EXP# 1,2 AND 4 BRICKS DAMAGED ERODED MORTAR JOINTS. LINTELS CORRODED AT MULTIPLE LOCATIONS AND SP
#39098341J
Jan 10, 2024
IN VIOLATION
$1,969
Jun 16, 2023Elevators CLASS - 1
CLASS 1::: FILE AND OBTAIN PERMIT TO INSTALL DLM ON THIS DEVICE. THIS IS A SAFETY SYSTEM REQUIRED TO BE ON ALL ELEVATORS. EMAIL EIR@BUILDINGS.NYC.GOV FOR A REINSPECTION TO BE DONE ON THIS DEVICE. CLASS 2::: REP
#39088672P
Aug 23, 2023
IN VIOLATION
$0
Mar 2, 2022Construction CLASS - 1
AT EXP.#2 AND 4 FIRE ESCAPE LADDER LANDING AREA EXCESSIVE DEBRIS AND HOUSEHOLD ITEMS. CLEAR EXIT PASSAGEWAY TO STREET PARTIALLY OBSTRUCTED BY DEBRIS. FIRE ESCAPE AT EXP. 1 AND 3 FIRE ESCAPE CLEAR PASSAGEWAY OBS
#39057270K
Jul 6, 2022
DEFAULT
$0
Feb 24, 2020Boilers CLASS - 2
SOOT AROUND BOILER,MISSING GUARD ON SUPPLY PUMP,SEAL BASE OF CHIMNEY
#39018124K
Jul 1, 2020
STIPULATION/IN-VIO
$0
Oct 28, 2019Boilers CLASS - 2
THERE IS STORAGE AT THE OIL TANK-THERE IS STORAGE AT THE GAS METERS; CORRECT VIOLATIONS AND SUBMIT THE CERTIFICATE OF CORRECTION
#39011859J
Oct 2, 2020
DEFAULT
$0
Jan 2, 2019Boilers CLASS - 2
GAS PIOLIT REGULATOR IS MISSING VENT LIMITER-REAR FLAME SIGHT GLASS IS MISSING-OIL PUMP BELT GUARD IS MISSING-BURNER IS SMOKING ON START-OIL TANK INTEGRITY AFFIDAVIT REQUIRED-BOILER ROOM FRESH AIR INLET IS NOT
#39001048R
Jun 3, 2019
IN VIOLATION
$0
Nov 9, 2013Construction CLASS - 2
WORK W/O A PERMIT. WORK NOTED: ATP 4F APT 4F ERECTED FULL HEIGHT PARTITION (6 INCHES BELOW CEILING) REMEDY: IMMEDIATELY MAKE SAFE REMOVE PARITION.
#35029198L
Dec 30, 2013
DEFAULT
$0
Apr 23, 2012Boilers CLASS - 2
B254,15,32A,34A,50A,B,C,D,E. 50A- MISSING PULLY GUARD @ TRANSFER PUMP,50B- IMPROPER SEAL @ BOILER CHAMBER DOOR, 50C- UNDER CARRIAGE OF BOILER DISINTEGRATING, 50D- WATER LINE LEAK, 50E-CIRCULATING PUMP DEFECTIVE
#32071941Z
Jun 11, 2012
IN VIOLATION
$0
Mar 27, 2006Quality of Life Hazardous
OCCUPANCY CONTRARY TO THAT ALLOWED BY BUILDING DEPARTMENT RECORDS: FROM; ORDINARY AND ACCESSORY USE IN CELLAR. TO: ORDINARY AND ACCESSARY USE AND TWO BEDROOMS, BATHROOM WITH SHOWER AND SPACE FOR KITCHEN WITH
#34511911R
Jan 29, 2007
IN VIOLATION
$0
Mar 27, 2006Quality of Life Hazardous
WORK W/O A PERMIT. WORK NOTED:CREATED TWO BEDROOMS IN CELLAR W/O WINDOWS, SPACE FOR KITCHEN WITH GAS STOVE, BATHROOM WITH SHOWER. REMEDY:RESTORE PREMISES TO PRIOR LEGAL CONDITION IMMEDIATELY
#34511912Z
Jan 29, 2007
WRITTEN OFF
$0
DOB (39)
IssuedViolationStatus
Nov 14, 2025LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
#09364
DOB VIOLATION - ACTIVE
Feb 7, 2024FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00082
DOB VIOLATION - ACTIVE
Oct 4, 2023FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#01563
DOB VIOLATION - ACTIVE
Jun 20, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION
#38952
DOB VIOLATION - ACTIVE
Jun 20, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION
#18835
DOB VIOLATION - ACTIVE
Mar 3, 2020ELEVATOR

#9028/674109
DOB VIOLATION - ACTIVE
Feb 2, 2020FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#00540
DOB VIOLATION - ACTIVE
Nov 2, 2019FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#00699
DOB VIOLATION - ACTIVE
Aug 2, 2019FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#01056
DOB VIOLATION - ACTIVE
May 2, 2019FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#01978
DOB VIOLATION - ACTIVE
Feb 16, 2019ELEVATOR

#9028/645978
DOB VIOLATION - ACTIVE
Feb 27, 2018ELEVATOR

#9028/622724
DOB VIOLATION - ACTIVE
Jan 26, 2018(OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION
VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2016 CAT 1 INSP/TST
#13019
DOB VIOLATION - ACTIVE
Feb 12, 2017ELEVATOR

#9028/597698
DOB VIOLATION - ACTIVE
Dec 1, 2016ELEVATOR ANNUAL INSPECTION / TEST
VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2015 INSPECTION/TEST
#05271
DOB VIOLATION - ACTIVE
Jun 1, 2016ELEVATOR

#EVCAT580486
DOB VIOLATION - ACTIVE
Mar 16, 2016ELEVATOR

#9028/571419
DOB VIOLATION - ACTIVE
Aug 18, 2015ELEVATOR

#9027/552674
DOB VIOLATION - ACTIVE
Jun 10, 2015ELEVATOR ANNUAL INSPECTION / TEST
VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2014 INSPECTION/TEST
#05387
DOB VIOLATION - ACTIVE
Oct 31, 2014ELEVATOR ANNUAL INSPECTION / TEST
VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2013 INSPECTION/TEST
#06196
DOB VIOLATION - ACTIVE
Sep 2, 2014ELEVATOR

#9027/522583
DOB VIOLATION - ACTIVE
Mar 31, 2014ELEVATOR ANNUAL INSPECTION / TEST
VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2012 INSPECTION/TEST
#09208
DOB VIOLATION - ACTIVE
Jul 8, 2013ELEVATOR

#9027/472071
DOB VIOLATION - ACTIVE
Oct 1, 2012ELEVATOR ANNUAL INSPECTION / TEST
VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2011 INSPECTION/TEST
#02573
DOB VIOLATION - ACTIVE
May 22, 2012ELEVATOR

#9027/427091
DOB VIOLATION - ACTIVE
Dec 13, 2011ELEVATOR ANNUAL INSPECTION / TEST
VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2010 INSPECTION/TEST
#02792
DOB VIOLATION - ACTIVE
Apr 26, 2011ELEVATOR

#9028/372397
DOB VIOLATION - ACTIVE
Mar 13, 2009ELEVATOR

#9011/292041
DOB VIOLATION - ACTIVE
Sep 30, 2008ELEVATOR

#9011/279150
DOB VIOLATION - ACTIVE
Feb 15, 2008ELEVATOR

#9011/239246
DOB VIOLATION - ACTIVE
Nov 19, 2004LOCAL LAW 10/81 - ELEVATOR

#02224
DOB VIOLATION - ACTIVE
Mar 21, 2003LOCAL LAW 10/81 - ELEVATOR

#02004
DOB VIOLATION - ACTIVE
Mar 8, 2001LOCAL LAW 10/81 - ELEVATOR

#02164
DOB VIOLATION - ACTIVE
Jan 13, 1997LOCAL LAW 10/81 - ELEVATOR

#02700
DOB VIOLATION - ACTIVE
Jan 13, 1997LOCAL LAW 10/81 - ELEVATOR

#02682
DOB VIOLATION - ACTIVE
Aug 29, 1995LOCAL LAW 62/91 - BOILERS

#37184
DOB VIOLATION - ACTIVE
May 31, 1994LOCAL LAW 10/81 - ELEVATOR

#02124
DOB VIOLATION - ACTIVE
Aug 16, 1993LOCAL LAW 62/91 - BOILERS

#37195
DOB VIOLATION - ACTIVE
Mar 3, 1992ELEVATOR

#1456D02
DOB VIOLATION - ACTIVE
DOB NOW Safety (28)
IssuedViolationStatus
Nov 14, 2025Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
Active
Aug 29, 2025Elevators FTF-VT-PER-CO
Violation Issued-Failure To File 2024 Periodic Inspection Report
Active
Aug 29, 2025Elevators FTF-VT-CAT1-CO
Violation Issued-Failure To File 2024 Cat1 Test Report
Active
Feb 7, 2024AEUHAZ FTC-AEU-HAZ
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2020 Cat1 Test Affirmation of Correction
Active
Oct 4, 2023AEUHAZ FTC-AEU-HAZ
Active
Aug 25, 2023Elevators FTF-VT-PER-CO
Violation Issued-Failure To File 2022 Periodic Inspection Report
Active
Aug 11, 2023Elevators FTF-VT-CAT1-CO
Violation Issued-Failure To File 2022 Cat1 Test Report
Active
Jun 20, 2023Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION
Active
Jun 20, 2023Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION
Active
Feb 2, 2020Benchmarking - LL84 FTF-EN-BENCH
Active
Nov 2, 2019Benchmarking - LL84 FTF-EN-BENCH
Active
Aug 2, 2019Benchmarking - LL84 FTF-EN-BENCH
Active
May 20, 2019Elevators EVCAT5
Active
May 2, 2019Benchmarking - LL84 FTF-EN-BENCH
Active
Jan 26, 2018Elevators ACC1
Active
Dec 1, 2016Elevators EVCAT1
Active
Jun 1, 2016Elevators E
Active
Jun 10, 2015Elevators EVCAT1
Active
Oct 31, 2014Elevators EVCAT1
Active
Mar 31, 2014Elevators EVCAT1
Active
Oct 1, 2012Elevators EVCAT1
Active
Dec 13, 2011Elevators EVCAT1
Active
Nov 19, 2004Elevators LL1081
Active
Mar 21, 2003Elevators LL1081
Active
Mar 8, 2001Elevators LL1081
Active
Jan 13, 1997Elevators LL1081
Active
May 31, 1994Elevators LL1081
Active
HPD (259) · C 123 · B 104 · A 31
IssuedClassViolationCorrect by
Oct 23, 2026B§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AND NORTH WALL AT PUBLIC HALL, 6th STORY—
Oct 23, 2026BApt 6B · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 6B, 6th STORY, 1st APARTMENT FROM WEST AT NORTH—
Jan 31, 2025I§27-2153 ADM CODE THE PREMISES HAS BEEN SELECTED TO PARTICIPATE IN THE ALTERNATIVE ENFORCEMENT PROGRAM WHICH MAY RESULT IN BUILDING-WIDE INSPECTIONS, FEES, AND EXTENSIVE REPAIR WORK TO CORRECT VIOLATIONS AND UNDERLYING CONDITIONS. CHARGES FOR REPAIR WORK DONE PURSUANT TO THIS ORDER, IF NOT PAID, WIL—
Oct 23, 2026BApt 6B · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 6B, 6th STORY, 1st APARTMENT FROM WEST AT NORTH—
Oct 23, 2026BApt 6B · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT FLOOR IN THE BATHROOM LOCATED AT APT 6B, 6th STORY, 1st APARTMENT FROM WEST AT NORTH—
Oct 23, 2026CApt 6B · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING AND NORTH WALL IN THE 3rd ROOM FROM EAST LOCATED AT APT 6B, 6th STORY, 1st APARTMENT FROM WEST AT NORTH—
Oct 23, 2026BApt 6B · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND NORTH WALL IN THE 3rd ROOM FROM EAST LOCATED AT APT 6B, 6th STORY, 1st APARTMENT FROM WEST AT NORTH—
Oct 23, 2026BApt 6B · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE KITCHEN LOCATED AT APT 6B, 6th STORY, 1st APARTMENT FROM WEST AT NORTH—
Oct 23, 2026BApt 6B · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING IN THE KITCHEN LOCATED AT APT 6B, 6th STORY, 1st APARTMENT FROM WEST AT NORTH—
Oct 23, 2026A§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AND NORTH WALL AT PUBLIC HALL, 6th STORY—
Sep 18, 2026CApt 4H · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 4H, 4th STORY, 1st APARTMENT FROM SOUTH AT WESTSep 24, 2026
Sep 18, 2026CApt 4H · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 4H, 4th STORY, 1st APARTMENT FROM SOUTH AT WESTSep 24, 2026
Sep 18, 2026CApt 4H · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND SOUTH WALL IN THE 3rd ROOM FROM EAST AT SOUTH LOCATED AT APT 4H, 4th STORY, 1st APARTMENT FROM SOUTH AT WESTSep 24, 2026
Aug 27, 2026CApt 2F · § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF FLICKERING LIGHT FIXTURE AT NORTH WALL IN THE BATHROOM LOCATED AT APT 2F, 2nd STORY, 3rd APARTMENT FROM NORTH AT EASTSep 2, 2026
Aug 27, 2026CApt 2F · § 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES AT NORTH WALL IN THE BATHROOM LOCATED AT APT 2F, 2nd STORY, 3rd APARTMENT FROM NORTH AT EASTSep 2, 2026
Aug 27, 2026AApt 2F · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING IN THE BATHROOM LOCATED AT APT 2F, 2nd STORY, 3rd APARTMENT FROM NORTH AT EASTNov 30, 2026
Aug 27, 2026CApt 2F · § 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION SPEEDY VALE AT BASE KITCHEN CABINET IN THE KITCHEN LOCATED AT APT 2F, 2nd STORY, 3rd APARTMENT FROM NORTH AT EASTSep 2, 2026
Aug 27, 2026BApt 2F · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 2F, 2nd STORY, 3rd APARTMENT FROM NORTH AT EASTOct 1, 2026
Aug 21, 2026B§ 27-2005 HMC: REFIT COMPACTOR ROOM DOOR AT PUBLIC HALL, 1st STORYSep 25, 2026
Aug 21, 2026C§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE COMPACTOR ROOM DOOR AT PUBLIC HALL, 1st STORYSep 4, 2026
Aug 20, 2026BApt 1F · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE KITCHEN LOCATED AT APT 1F, 1st STORY, 3rd APARTMENT FROM NORTH AT EASTSep 24, 2026
Aug 20, 2026CApt 1F · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE KITCHEN LOCATED AT APT 1F, 1st STORY, 3rd APARTMENT FROM NORTH AT EASTAug 26, 2026
Aug 20, 2026CApt 1F · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 1F, 1st STORY, 3rd APARTMENT FROM NORTH AT EASTSep 15, 2026
Aug 12, 2026BApt 5A · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE BUZZER/INTERCOM FROM BUILDING FRONT ENTRANCE TO IN THE ENTIRE APARTMENT LOCATED AT APT 5A, 5th STORY, 3rd APARTMENT FROM SOUTH AT WESTSep 16, 2026
Aug 12, 2026C§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT BULKHEAD DOOR TO ROOFAug 26, 2026
Aug 12, 2026B§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE COPING STONE AT WEST PARAPET WALL AT ROOFSep 16, 2026
Jul 31, 2026CApt 6A · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE WINDOW BALANCE LOWER SASH AT WEST WALL IN THE 4th ROOM FROM EAST AT SOUTH LOCATED AT APT 6A, 6th STORY, 3rd APARTMENT FROM SOUTH AT WESTAug 6, 2026
Jul 31, 2026CApt 6A · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE WINDOW BALANCE UPPER SASH FIRE ESCAPE WINDOW AT NORTH WALL IN THE 2nd ROOM FROM EAST LOCATED AT APT 6A, 6th STORY, 3rd APARTMENT FROM SOUTH AT WESTAug 6, 2026
Jul 31, 2026CApt 6A · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE WINDOW BALANCE LOWER SASH AT WEST WALL IN THE 4th ROOM FROM EAST AT NORTH LOCATED AT APT 6A, 6th STORY, 3rd APARTMENT FROM SOUTH AT WESTAug 6, 2026
Feb 9, 2026BApt 6B · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 6B, 6th STORY, 1st APARTMENT FROM WEST AT NORTHMar 16, 2026
Feb 9, 2026AApt 6B · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL TILES AT FLOOR IN THE KITCHEN LOCATED AT APT 6B, 6th STORY, 1st APARTMENT FROM WEST AT NORTHMay 15, 2026
Dec 29, 2025CApt 6H · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 6H, 6th STORY, 1st APARTMENT FROM SOUTH AT WESTJan 24, 2026
Dec 29, 2025CApt 6H · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING AND ALL WALLS MORETHAN 30 SQ. FEET IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 6H, 6th STORY, 1st APARTMENT FROM SOUTH AT WESTJan 24, 2026
Nov 28, 2025BApt 5H · § 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM WINDOW TO FIRE ESCAPE OR PROVIDE APPROVED TYPE GATE IN THE 3rd ROOM FROM NORTH LOCATED AT APT 5H, 5th STORY, 1st APARTMENT FROM SOUTH AT WESTJan 2, 2026
Nov 28, 2025B§ 27-2005 HMC: REFIT DOOR AT COMPACTOR CLOSET, 1st STORYJan 2, 2026
Nov 28, 2025CApt 5H · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 5H, 5th STORY, 1st APARTMENT FROM SOUTH AT WESTDec 24, 2025
Nov 28, 2025CApt 5H · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 5H, 5th STORY, 1st APARTMENT FROM SOUTH AT WESTDec 24, 2025
Nov 28, 2025BApt 5H · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR ALL WALLS AND CEILING IN THE BATHROOM LOCATED AT APT 5H, 5th STORY, 1st APARTMENT FROM SOUTH AT WESTJan 2, 2026
Nov 28, 2025BApt 5H · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT EAST WALL IN THE PRIVATE HALLWAY LOCATED AT APT 5H, 5th STORY, 1st APARTMENT FROM SOUTH AT WESTJan 2, 2026
Sep 17, 2025C§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT CELLARSep 23, 2025
Sep 17, 2025CApt 6B · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 6B, 6th STORY, 1st APARTMENT FROM WEST AT NORTHSep 17, 2025
Sep 4, 2025AApt 6B · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES IN THE KITCHEN , THE BATHROOM , THE 3rd ROOM FROM EAST LOCATED AT APT 6B, 6th STORY, 1st APARTMENT FROM WEST AT NORTHDec 8, 2025
Sep 4, 2025BApt 6B · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER THE CEILING IN THE BATHROOM LOCATED AT APT 6B, 6th STORY, 1st APARTMENT FROM WEST AT NORTHOct 9, 2025
Sep 4, 2025BApt 6B · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT THE NORTH WALL IN THE 3rd ROOM FROM EAST LOCATED AT APT 6B, 6th STORY, 1st APARTMENT FROM WEST AT NORTHOct 9, 2025
Sep 4, 2025BApt 6B · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK OVER THE CEILING IN THE 3rd ROOM FROM EAST LOCATED AT APT 6B, 6th STORY, 1st APARTMENT FROM WEST AT NORTHOct 9, 2025
Sep 4, 2025CApt 6B · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 6B, 6th STORY, 1st APARTMENT FROM WEST AT NORTHSep 30, 2025
Sep 4, 2025C§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM NO ACCESS TO BOILER ROOM, ELEVATOR IS OUT OF SERVICE AT BOILER ROOM, 1st STORYSep 10, 2025
Sep 4, 2025CApt 6B · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD-PAINT THAT IS XRF TESTED INCONCLUSIVE FOR LEAD CONTENT AT 0.5MG/CM2 AND IS PRESUMED LEAD PAINT AS SET FORTH IN (28 RCNY §11-07(b)) AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE-USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(b)(2) 1stSep 28, 2025
Sep 4, 2025CApt 6B · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 6B, 6th STORY, 1st APARTMENT FROM WEST AT NORTHSep 4, 2025
Sep 4, 2025BApt 6B · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 6B, 6th STORY, 1st APARTMENT FROM WEST AT NORTHOct 9, 2025
Sep 4, 2025BApt 6B · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 6B, 6th STORY, 1st APARTMENT FROM WEST AT NORTHOct 9, 2025
Sep 4, 2025CApt 6B · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st DOOR FROM EAST AT SOUTH WALL IN THE FOYER LOCATED AT APT 6B, 6th STORY, 1st APARTMSep 28, 2025
Sep 4, 2025CApt 6B · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 6B, 6th STORY, 1st APARTMENT FROM WEST AT NORTHSep 30, 2025
Aug 14, 2025CApt 5H · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 5H, 5th STORY, 1st APARTMENT FROM NORTH AT EASTAug 20, 2025
Aug 13, 2025BApt 6B · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD SUB-FLOOR IN THE KITCHEN LOCATED AT APT 6B, 6th STORY, 1st APARTMENT FROM WEST AT NORTHSep 17, 2025
Aug 13, 2025BApt 6B · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD LINTEL (OFFSET 2) IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 6B, 6th STORY, 1st APARTMENT FROM WEST AT NORTHSep 17, 2025
Aug 13, 2025BApt 6B · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 6B, 6th STORY, 1st APARTMENT FROM WEST AT NORTHSep 17, 2025
Aug 13, 2025BApt 6B · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 6B, 6th STORY, 1st APARTMENT FROM WEST AT NORTHSep 17, 2025
Aug 13, 2025BApt 6B · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND NORTH WALL IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 6B, 6th STORY, 1st APARTMENT FROM WEST AT NORTHSep 17, 2025
Aug 13, 2025BApt 6B · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 6B, 6th STORY, 1st APARTMENT FROM WEST AT NORTHSep 17, 2025

Showing 60 of 259. Full list on the agency site.

Issued in the last 120 days

DateSourceWhatNow
Oct 23, 2026HPD B§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATERIAL AT CEILING AND NORTH WALL AT PUBLIC HALL, 6th STORYOpen
Oct 23, 2026HPD B§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 6B, 6th STORY, 1st APARTMENT FROM WEST AT NORTHOpen
Oct 23, 2026HPD B§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 6B, 6th STORY, 1st APARTMENT FROM WEST AT NORTHOpen
Oct 23, 2026HPD B§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT FLOOR IN THE BATHROOM LOCATED AT APT 6B, 6th STORY, 1st APARTMENT FROM WEST AT NORTHOpen
Oct 23, 2026HPD C§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING AND NORTH WALL IN THE 3rd ROOM FROM EAST LOCATED AT APT 6B, 6th STORY, 1st APARTMENT FROM WEST AT NORTHOpen
Oct 23, 2026HPD B§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND NORTH WALL IN THE 3rd ROOM FROM EAST LOCATED AT APT 6B, 6th STORY, 1st APARTMENT FROM WEST AT NORTHOpen
Oct 23, 2026HPD B§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE KITCHEN LOCATED AT APT 6B, 6th STORY, 1st APARTMENT FROM WEST AT NORTHOpen
Oct 23, 2026HPD B§ 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING IN THE KITCHEN LOCATED AT APT 6B, 6th STORY, 1st APARTMENT FROM WEST AT NORTHOpen
Oct 23, 2026HPD A§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AND NORTH WALL AT PUBLIC HALL, 6th STORYOpen
Sep 18, 2026HPD C§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 4H, 4th STORY, 1st APARTMENT FROM SOUTH AT WESTOpen
Sep 18, 2026HPD C§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 4H, 4th STORY, 1st APARTMENT FROM SOUTH AT WESTOpen
Sep 18, 2026HPD C§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND SOUTH WALL IN THE 3rd ROOM FROM EAST AT SOUTH LOCATED AT APT 4H, 4th STORY, 1st APARTMENT FROM SOUTH AT WESTOpen
Aug 27, 2026HPD C§ 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF FLICKERING LIGHT FIXTURE AT NORTH WALL IN THE BATHROOM LOCATED AT APT 2F, 2nd STORY, 3rd APARTMENT FROM NORTH AT EASTOpen
Aug 27, 2026HPD C§ 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES AT NORTH WALL IN THE BATHROOM LOCATED AT APT 2F, 2nd STORY, 3rd APARTMENT FROM NORTH AT EASTOpen
Aug 27, 2026HPD A§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING IN THE BATHROOM LOCATED AT APT 2F, 2nd STORY, 3rd APARTMENT FROM NORTH AT EASTOpen
Aug 27, 2026HPD C§ 27-2026 ADM CODE REPAIR THE BROKEN OR DEFECTIVE CONNECTION SPEEDY VALE AT BASE KITCHEN CABINET IN THE KITCHEN LOCATED AT APT 2F, 2nd STORY, 3rd APARTMENT FROM NORTH AT EASTOpen
Aug 27, 2026HPD B§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 2F, 2nd STORY, 3rd APARTMENT FROM NORTH AT EASTOpen
Aug 21, 2026HPD B§ 27-2005 HMC: REFIT COMPACTOR ROOM DOOR AT PUBLIC HALL, 1st STORYOpen
Aug 21, 2026HPD C§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE COMPACTOR ROOM DOOR AT PUBLIC HALL, 1st STORYOpen
Aug 20, 2026HPD B§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE KITCHEN LOCATED AT APT 1F, 1st STORY, 3rd APARTMENT FROM NORTH AT EASTOpen
Aug 20, 2026HPD C§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE KITCHEN LOCATED AT APT 1F, 1st STORY, 3rd APARTMENT FROM NORTH AT EASTOpen
Aug 20, 2026HPD CHMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 1F, 1st STORY, 3rd APARTMENT FROM NORTH AT EASTOpen
Aug 12, 2026HPD B§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE BUZZER/INTERCOM FROM BUILDING FRONT ENTRANCE TO IN THE ENTIRE APARTMENT LOCATED AT APT 5A, 5th STORY, 3rd APARTMENT FROM SOUTH AT WESTOpen
Aug 12, 2026HPD C§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT BULKHEAD DOOR TO ROOFOpen
Aug 12, 2026HPD B§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE COPING STONE AT WEST PARAPET WALL AT ROOFOpen

Check the agency records