Manhattan · Block 1772 · Lot 52 · 10035

150 East 124 Street

5 floors · 16,595 sq ft · built 1920 · class N2 · owner of record: L & S Properties 3 Llc

5open violations
$3,750ECB/OATH penalties owed
0HPD class C (immediately hazardous)
409dto Gas piping inspection (2027 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 44 days
Keep the report on file (not filed with DOB)
Gas piping inspection (2027 cycle) Likely applies
Local Law 152 · During 2027
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 11 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2027
in 409 days
Next cycle year 2027
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-09-30 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (3) · $3,750 owed
IssuedViolationHearingBalance
Aug 17, 2026Construction CLASS - 1
AT THE TIME OF INSPECTION OBSERVED OBSTRUCTED SPRINKLER HEADS AND LACK OF SPRINKLER COVERAGE THIS IS CONTRARY TO BC903.3.3, WHICH REQUIRES AUTOMATIC SPRINKLERS TO BE INSTALLED WITH DUE REGARD TO OBSTRUCTIONS TH
#39200752M
Dec 3, 2026
PENDING
$2,500
Aug 17, 2026Construction CLASS - 2
AT THE TIME OF INSPECTION OBSERVED THROUGHOUT THE BUILDING PVC PIPING BEING USED UNDER THE BATHROOM SINK VANITIES AND THROUGHOUT THE BASEMENT THIS IS CONTRARY TO PC 1101.10 PVC PIPING USED FOR WASTE PIPING WAS
#39200751K
Dec 3, 2026
PENDING
$1,250
Aug 19, 2024Construction CLASS - 2
CLOSET BUILT WITH EXCESSIVE STORAGE OF OFFICE MATERIAL INSIDE ELECTRICAL MECHANICAL ROOM LOCATED AT CELLAR/BASEMENT LEVEL AND WITHOUT DOB APPROVAL/ PERMITS., OBTAIN ALL PERMITS
#39122374N
May 5, 2025
IN VIOLATION
$0
DOB (1)
IssuedViolationStatus
Feb 24, 2026CONSTRUCTION
FTM BLDG IN A CODE COMPLIANT MANNER-OBSVD @ EXP4 NEAR EXP3/4 PARAPET LOOSE/DELAMINATED MATERIAL ABOVE COURTYARD AREA. OWNER TO IMMED RETAIN NYSPE TO EVAL ENTIE BLDG,PREPARE/FILE REPAIR DWGS,REPAIR BLDG UNDER PERMIT,START WORK BY 04/24/2026. COMPLETE/SIGN OFF WORK BY 06/24/26
#PI11101SB
DOB VIOLATION - ACTIVE
DOB NOW Safety (1)
IssuedViolationStatus
Dec 15, 2025Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2024 External Inspection Affirmation of Correction for LP Device
Active
HPD (0)

None open.

Issued in the last 120 days

DateSourceWhatNow
Aug 17, 2026ECBConstruction: AT THE TIME OF INSPECTION OBSERVED OBSTRUCTED SPRINKLER HEADS AND LACK OF SPRINKLER COVERAGE THIS IS CONTRARY TO BC903.3.3, WHICH REQUIRES AUTOMATIC SPRINKLERS TO BE INSTALLED WITH DUE REGARD TO OBSTRUCTIONS THOpen
Aug 17, 2026ECBConstruction: AT THE TIME OF INSPECTION OBSERVED THROUGHOUT THE BUILDING PVC PIPING BEING USED UNDER THE BATHROOM SINK VANITIES AND THROUGHOUT THE BASEMENT THIS IS CONTRARY TO PC 1101.10 PVC PIPING USED FOR WASTE PIPING WASOpen