Staten Island · Block 5 · Lot 1 · 10301

150 Bay Street

3 floors · 4,800 sq ft · built 1930 · class O5 · owner of record: A & B Associates

20open violations
$0ECB/OATH penalties owed
0HPD class C (immediately hazardous)
774dto Gas piping inspection (2028 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 43 days
Keep the report on file (not filed with DOB)
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 774 days
Next cycle year 2028
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-02-25 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (8)
IssuedViolationHearingBalance
Mar 11, 2016Construction CLASS - 1
OCCUPANCY CONTRARY TO THAT ALLOWED BY RHE C OF O OR BLDG DEPT RECORDS.NOTED: C OF O #22341 DATED 5/17/62 LISTED THE CELLAR OF BLDG AS COMMERICIAL PRINTERS & STATIONERS,FURNACE ROOM & STORAGE ROOM. AT TIME OF IN
#35123985L
May 4, 2016
IN VIOLATION
$0
Mar 11, 2016Unknown CLASS - 1
SEC. 110.26 INSUFFIENT WORKING CLEARANCE AROUND ELECTRICAL PANELS. @ TIME OF INSPECTION,OBSERVED ELECTRICAL SERVICE AT CELLAR LEVEL,BLOCKED BY MISC DEBRIS CRATES,CURTAINS,BOXES,LIGHTING BOXES & SHELVING UNITS.
#35135091K
May 4, 2016
IN VIOLATION
$0
Mar 11, 2016Unknown CLASS - 1
UNAPPROVED,UNSAFE,DEFECTIVE WIRING IS IN USE. @ TIME OF INSPECTION. ATCELLAR LEVEL,OBSERVED MISC DEBRIS BLOCKING ELECTRICAL METERS,CURTAINS,BOXES,MISC DEBRIS,JUNCTION BOXES NOT COVERED THROUGHOUT ELECTRICAL OUT
#35135092M
May 4, 2016
IN VIOLATION
$0
Mar 11, 2016Construction CLASS - 1
WORK W/O A PERMIT. NOTE: AT TIME OF INSPECTION 3PM I OBSERVED A KITCHEN SINK IN BASEMENT,AS WELL AS A WATER CLOSET & STAND UP SHOWER LOCATED IN BASEMENT. REMEDY: OBTAIN PERMIT OR RESTORE PREMISES TO PRIOR LEGAL
#35142559M
May 4, 2016
IN VIOLATION
$0
Mar 11, 2016Unknown CLASS - 1
DEFECTIVE WIRING IS IN USE. AT TIME OF INSPECTION AT CELLAR LEVEL,OBSERVED USE OF EXTENSION CORDS THROUGHOUT CEILING,FLOORS & WALLS. CORD USED FOR LIGHTS FOR CONCERT STORAGE,USED FOR POWER ON STAGE,POWER FOR
#35135093Y
May 4, 2016
IN VIOLATION
$0
Nov 15, 2006Signs Non-Hazardous
HAVING A SIGN EXTENDING HIGHER THEN 40FT ABOVE CURB LEVEL. REMEDY:REMOVE ILLEGAL SIGNAGE.
#34543260Z
Aug 2, 2007
IN VIOLATION
$0
Nov 15, 2006Signs Non-Hazardous
HAVING PROHIBITED ADVERTISING SIGNAGE IN C4-2 DISTRICT. REMEDY: REMOVE ILLEGAL SIGNAGE.
#34543257H
Aug 2, 2007
IN VIOLATION
$0
Nov 15, 2006Signs Non-Hazardous
HAVING SIGNAGE ON ROOF. REMEDY: REMOVE ILLEGAL SIGNAGE.
#34543259L
Aug 2, 2007
IN VIOLATION
$0
DOB (7)
IssuedViolationStatus
Jun 30, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION
#12097
DOB VIOLATION - ACTIVE
Jun 20, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION
#32912
DOB VIOLATION - ACTIVE
Nov 8, 2019LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2017 INSPECTION REPORT
#15915
DOB VIOLATION - ACTIVE
Apr 6, 2018LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2016 INSPECTION REPORT
#19123
DOB VIOLATION - ACTIVE
Mar 11, 2016CONSTRUCTION

#COBM01RHO
DOB VIOLATION - ACTIVE
May 15, 2014LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT
#20841
DOB VIOLATION - ACTIVE
Apr 18, 2001CONSTRUCTION

#ZSTF01YC
DOB VIOLATION - ACTIVE
DOB NOW Safety (5)
IssuedViolationStatus
Jun 30, 2023Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION
Active
Jun 20, 2023Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION
Active
Nov 8, 2019Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2017 INSPECTION REPORT
Active
Apr 6, 2018Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2016 INSPECTION REPORT
Active
May 15, 2014Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT
Active
HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 18, 2026, 4:47 AM ET. BBL 5000050001.