Brooklyn · Block 2626 · Lot 30 · 11222

15 Moultrie Street

4 floors · 16 apartments · 6,800 sq ft · built 1930 · class C7 · owner of record: H.J. Wolanski, Llc

28open violations
$0ECB/OATH penalties owed
4HPD class C (immediately hazardous)
62dto Bedbug annual filing

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 62 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 62 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 78 days
Annual
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 306 days
Registered through 2027-09-01
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 793 days
Next cycle year 2028
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-07-10 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (1)
IssuedViolationHearingBalance
Jun 2, 2020Boilers CLASS - 2
NO BOILER ROOM ACCESS SIGN VISIBLE FROM DOOR; CORRECT VIOLATING CONDITION & SUBMIT A CERTIFICATE OF CORRECTION
#39023278J
Oct 7, 2020
IN VIOLATION
$0
DOB (2)
IssuedViolationStatus
Oct 1, 2015LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2014 INSPECTION REPORT
#05573
DOB VIOLATION - ACTIVE
Aug 29, 1995LOCAL LAW 62/91 - BOILERS

#22146
DOB VIOLATION - ACTIVE
DOB NOW Safety (4)
IssuedViolationStatus
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2020 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2021 External Inspection Affirmation of Correction for LP Device
Active
Oct 1, 2015Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2014 INSPECTION REPORT
Active
Aug 29, 1995Boiler LL6291
Active
HPD (21) · C 4 · B 7 · A 10
IssuedClassViolationCorrect by
Sep 3, 2024AApt 12 · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE BELL AND BUZZER RETURN SYSEM FROM VESTIBULE TO FOYER IN THE FOYER LOCATED AT APT 12, 3rd STORY, 1st APARTMENT FROM WEST AT NORTHDec 7, 2024
Sep 3, 2024CApt 12 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 12, 3rd STORY, 1st APARTMENT FROM WEST AT NORTHSep 29, 2024
Jan 19, 2024BApt 1 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING AT SHOWER STALL (APPROX 1 SQ. FT.) IN THE 2nd ROOM FROM EAST AT SOUTH LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM NORTH AT EAST ORIGINAL VIOLATION 16222390 ISSUED 13-SEP-23 HAS BEEN UPGRADED TO CLASS Feb 23, 2024
Jan 19, 2024BApt 1 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING (APPROX 3 SQ. FT. IN THE KITCHEN LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM NORTH AT EAST ORIGINAL VIOLATION 16222383 ISSUED 13-SEP-23 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3aFeb 23, 2024
Sep 21, 2023AApt 1 · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM NORTH AT EASTDec 25, 2023
Sep 21, 2023CApt 1 · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE ... IN THE ENTRANCE LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM NORTH AT EASTOct 5, 2023
Sep 21, 2023AApt 1 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE BATHROOM LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM NORTH AT EASTDec 25, 2023
Sep 21, 2023BApt 1 · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF GAS METER IN THE BATHROOM LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM NORTH AT EASTOct 26, 2023
Sep 21, 2023AApt 1 · § 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION THE STEAM RISER AT WEST WALL IN THE BATHROOM LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM NORTH AT EASTDec 25, 2023
Sep 21, 2023AApt 1 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND EAST WALL IN THE KITCHEN LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM NORTH AT EASTDec 25, 2023
Sep 21, 2023AApt 1 · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE KITCHEN LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM NORTH AT EASTDec 25, 2023
Sep 21, 2023AApt 1 · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE SOUTH WALL IN THE KITCHEN LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM NORTH AT EASTDec 25, 2023
Sep 21, 2023AApt 1 · § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING ESCUTCHEON PLATE AT CEILING ABOVE STEAM RISER IN THE BATHROOM LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM NORTH AT EASTDec 25, 2023
Nov 30, 2022B§ 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES CONSISTING OF FLOWER POTS AT 3RD STORY BALCONY NORTHEAST STACK, BUILDING FRONTJan 4, 2023
Nov 30, 2022B§ 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES CONSISTING OF AIR CONDITIONERS PROTRUDING AT WINDOW SILL ON 2ND AND 4TH STORY BALCONIES NORTHEAST STACK, BUILDING FRONTJan 4, 2023
Nov 30, 2022B§ 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES CONSISTING OF HOUSEHOLD ITEMS AT 2ND STORY BALCONY SOUTHWEST STACK, BUILDING FRONTJan 4, 2023
Jun 9, 2015CApt 6 · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF WOOD SLAB WITH BEVELED SURFACE INSTALLED ON FLOOR INFRONT OF THE BATHROOM ENTRANCE DOOR LOCATED AT APT 6, 2nd STORY, 2nd APARTMENT FROM NORTH AT EASTJun 17, 2015
Oct 17, 2014BApt 6 · § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE BASE SINK CABINET IN THE KITCHEN LOCATED AT APT 6, 2nd STORY, 2nd APARTMENT FROM NORTH AT EASTNov 21, 2014
Oct 24, 2013A§ 53, 187, 231 M/D LAW AND DEPARTMENT RULES AND REGULATIONS. PROVIDE A SHOE PROPERLY SECURED TO BOTTOM OF STRING OF DROPLADDER AT NORTH SIDE BUILDING FRONT AT FIRE ESCAPEJan 27, 2014
Oct 21, 2013A§ 53, 187, 231 M/D LAW AND DEPARTMENT RULES AND REGULATIONS. PROVIDE A SHOE PROPERLY SECURED TO BOTTOM OF STRING OF DROPLADDER AT NORTH SIDE BUILDING FRONT AT FIRE ESCAPEJan 24, 2014
Sep 3, 2009CApt 14 · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE SEAL AROUND SHOWER PAN AT SHOWER STALL IN THE BATHROOM LOCATED AT APT 14, 4th STORY, APARTMENT AT EASTSep 9, 2009

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 30, 2026, 5:52 AM ET. BBL 3026260030.