4 floors · 89,966 sq ft · built 1954 · class W1 · owner of record: Nyc Department Of Education
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 48 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 89,966 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 169 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 169 days | Annual filing |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 7 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1144 days | Next cycle year 2029 |
| Energy audit and retro-commissioning (2029) Likely applies Local Law 87 · Calendar year 2029 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 1149). Agency page | Dec 31, 2029 in 1144 days | Next due 2029 |
| Annual boiler inspection (2 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-05-26 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Mar 19, 2026 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. USE OF PROHIBITED DOOR AND/OR HARDWARE PER BC 1008.1.8; 27-371(J). AT THE TIME OF INSPECTION, THE FOLLOWING ROOM DOORS HAD TURN KNOB HANDLES:-312, 309, 310 #35727139J | May 11, 2026 POP/IN-VIO | $0 |
| Mar 19, 2026 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. AT THE TIME OF INSPECTION, STAIRWELL "D" HAD WATER STAINS AND EFFLORESCENCE AS A RESULT OF ROOF OVERFLOW TEST. REMEDY: REPAIR AND/OR REPLACE. #35727141Z | May 11, 2026 POP/IN-VIO | $0 |
| Mar 19, 2026 | Construction CLASS - 2 RE-ISSUED 35717111Z. AT THE TIME OF INSPECTION, THE FOLLOWING EMERGENCY LIGHTS WERE INOPERABLE:-2-53, 2-6, 2-7, 1-17, B-8, B-5, 1 EMERGENCY LIGHTS OVER A EXIT DOOR FROM AUDITORIUM. REMEDY: REPAIR/REPLACE LIGHTI #35727140R | May 11, 2026 POP/IN-VIO | $0 |
| Mar 19, 2026 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. AT THE TIME OF INSPECTION, THE FOLLOWING ROOM DOORS WERE NOT SELF-CLOSING PROPERLY:-1DOOR ON 2ND FLOOR, 1 DOOR FROM 1ST FLOOR CAFETERIA, STAIRCASE "A" ON 1 #35727138H | May 11, 2026 POP/IN-VIO | $0 |
| Apr 11, 2025 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. ILLUMINATION FOR EXITS, EXIT DISCHARGES AND PUBLIC CORRIDORS. PER BC 1006.1; 27-381. AT THE TIME OF INSPECTION OBSERVED AND NOTED. AT 2ND FLOOR GYM 1 PLACE #35717111Z | May 19, 2025 POP/IN-VIO | $0 |
| Jul 22, 2024 | Construction CLASS - 1 OBSERVED UNSAFE STORAGE OF CONSTRUCTION MATERIALS AT STREET LEVEL ON 78 STREET SIDE EXP 1. BLOCKING FIRE HYDRANT ADJACENT TO THE JOBSITE WITH WORK MATERIALS. #39530699Y | Sep 26, 2024 IN VIOLATION | $0 |
| Jul 22, 2024 | Unknown CLASS - 1 OBSERVED AT 78 STREET SIDE OF ACTIVE JOBS AT PS 78. NO FLAG MAN OBSERVED AT TIME OF DELIVERY OPERATIONS AS REQUIRED PER 3307.4.3 #39530701Y | Sep 26, 2024 IN VIOLATION | $0 |
| Mar 5, 2021 | Construction CLASS - 2 FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER:NO FIRE STOPPING PERBC 712.3;27-345 NOTE AT CELLAR LEVEL IN ELECTRICAL ROOM NO FIRE STOPPING AROUND PIPES PENATRATING THROUGH WALL.REMEDY:PROVIDE & MAINTAIN FIR #35546445P | Jun 10, 2021 DEFAULT | $3,125 |
None open.
| Issued | Violation | Status |
|---|---|---|
| Dec 15, 2025 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2024 External Inspection Affirmation of Correction for LP Device | Active |
| Dec 15, 2025 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2024 External Inspection Affirmation of Correction for LP Device | Active |
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 13, 2026, 10:28 PM ET. BBL 1011490007.