2 floors · 2 apartments · 2,200 sq ft · built 1990 · class B2 · owner of record: Mclean, Leopold
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Check HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 313 days | Required only if the owner doesn't live there |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Feb 17, 2026 | Construction CLASS - 1 AT TIME OF INSPECTION, OBSERVED FULL HEIGHT PARTITIONS ERECTED TO SUB-DIVIDE THE GARAGE CREATING 3 PIECE BATHROOM NO PERMITS OR RECORDS ON BIS/DOB NOW FOR WORK OBSERVED., OBTAIN PERMIT #39177530Y | Apr 28, 2026 DEFAULT | $12,500 |
| Feb 17, 2026 | Construction CLASS - 1 AT TIME OF INSPECTION, OBSERVED ILLEGAL ELECTRICAL WORK COMPLETED IN ILLEGALLY CONVERTED GARAGE. INSTALLING OUTLETS, SWITCHES, AND LIGHT FIXTURES FOR BEDROOM, AND BATHROOM INSIDE ILLEGALLY CONVERTED GARAGE. NO #39177529R | Apr 28, 2026 DEFAULT | $12,500 |
| Feb 17, 2026 | Construction CLASS - 1 AT TIME OF INSPECTION, OBSERVED ILLEGAL PLUMBING WORK COMPLETED IN THE GARAGE. INSTALLING WATER, AND WASTE LINES FOR 3 PCS BATHROOM (SINK, TOILET, SHOWER/TUB) NO PERMITS OR RECORDS ON BIS/DOB NOW FOR WORK OBSER #39177528P | Apr 28, 2026 DEFAULT | $12,500 |
| Feb 17, 2026 | Construction CLASS - 1 ILLEGAL CONVERTED GARAGE INTO AN ADDITIONAL SLEEPING QUARTER WITH A 3 PCS BATHROOM WITH INSUFFICIENT NATURAL LIGHTING AND VENTILATION, NO SPRINKLER AND/OR 2ND MEANS OF EGRESS CONTRARY TO C OF O #205560, DISCONT #39177527N | Apr 28, 2026 DEFAULT | $12,500 |
None open.
None open.
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Jan 19, 2021 | B | Apt 2FL · § 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE METAL FRAME AT FLOOR AROUND CERAMIC TILES IN THE KITCHEN LOCATED AT APT 2FL, 2nd STORY | Feb 23, 2021 |
| Dec 29, 2020 | B | Apt 2FL · § 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE OVEN AT GAS RANGE IN THE KITCHEN LOCATED AT APT 2FL, 2nd STORY | Feb 2, 2021 |
| Dec 29, 2020 | B | Apt 2FL · § 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT FLOOR IN THE KITCHEN LOCATED AT APT 2FL, 2nd STORY | Feb 2, 2021 |
| Jul 8, 2010 | B | Apt 1A · § 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRICAL OUTLET AT WALLS IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 1A, 1st STORY | Aug 12, 2010 |
| Jul 8, 2010 | B | Apt 1A · § 27-2026 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE CONNECTION WASTE LINE UNDER WASH BASIN AT BATHROOM IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 1A, 1st STORY | Aug 12, 2010 |
| Jul 8, 2010 | B | Apt 1A · § 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE CEILING LIGHT FIXTURE IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 1A, 1st STORY | Aug 12, 2010 |
| Jul 8, 2010 | B | Apt 1A · § 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRICAL OUTLET AT NORTH WALL IN THE 3rd ROOM FROM EAST LOCATED AT APT 1A, 1st STORY | Aug 12, 2010 |
| Jul 8, 2010 | B | Apt 1A · § 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING ELECTRICAL OUTLET AT NORTH AND SOUTH WALL IN THE 3rd ROOM FROM EAST LOCATED AT APT 1A, 1st STORY | Aug 12, 2010 |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 23, 2026, 3:54 PM ET. BBL 4137120155.