2 floors · 21,000 sq ft · built 1989 · class N2 · owner of record: Nyc Department Of Homeless Services
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 60 days | Keep the report on file (not filed with DOB) |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 13 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1156 days | Next cycle year 2029 |
| Annual boiler inspection (2 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-03-06 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Jan 30, 2026 | Construction CLASS - 2 OBSERVED A POWERFLAME BURNER MODEL WCR3-G-20 SERIAL # 082287282 INSTALLED WITHOUT A PERMIT. OBTAIN THE PROPER PERMIT AND SUBMIT A CERTIFICATE OF CORRECTION. #39175413X | Feb 6, 2026 POP/IN-VIO | $0 |
| Dec 9, 2022 | Construction CLASS - 3 FOUND POWERFLAME GAS FIRED BURNER MODEL # WCR3-G-20, SERIAL # 082287282 BEING INSTALLED WITHOUT A PERMIT ON A WEIL MCLAIN MODEL 1288 BOILER. OBTAIN THE PROPER PERMIT AND SUBMIT A CERTIFICATE OF CORRECTION. #39075415L | Jan 11, 2023 POP/IN-VIO | $0 |
| Nov 22, 2022 | Construction CLASS - 2 OBSERVED ACTIVE WATER LEAK ON PUMP IN THE BOILER ROOM THAT IS LOCATED IN THE CELLAR. AS PER PC 102.3 MAINTENANCE. INSTALLATIONS, BOTH EXISTING AND NEW, AND PARTS THEREOF SHALL BE MAINTAINED IN PROPER OPERATING #39074350P | Dec 8, 2022 POP/IN-VIO | $0 |
| Nov 21, 2022 | Boilers CLASS - 2 CIRCULATOR LEAKING, NO FITTINGS/THREADS ON EXPANSION TANK RELIEF VALVE DISCHARGE PIPING TERMINATION, NO THREADS ON RELIEF PIPING TERMINATION FOR BACKFLOW PREVENTER. CORRECT ALL VIOLATING CONDITIONS AND SUBMIT A #39074205Z | Dec 8, 2022 POP/IN-VIO | $0 |
| Jan 26, 2022 | Construction CLASS - 1 UNLAWFUL ACTS FAILURE TO COMPLY W/COMMISSIONER'S ORDERS.RECORDS INDICATE NO APP WAS MADE TO CORRECT OR CERTIFY ECB #'S 35634552X & 35379762NREMEDY:COMPLY W/COMMISSIONER'S ORDERS #35644907J | May 24, 2022 POP/IN-VIO | $0 |
| Jan 11, 2022 | Construction CLASS - 2 I OBSERVED ACTIVE WATER LEAK AT THE EXPANSION TANK LOCATED IN THE BOILER ROOM AT CELLAR/BASEMENT LEVEL, BOILER #2 MISSING SITE GLASS AT REAR., REPAIR AND/OR REPLACE #39054079Z | Feb 11, 2022 POP/IN-VIO | $0 |
| Nov 4, 2021 | Construction CLASS - 1 UNLAWFUL ACTS.FAILURE TO COMPLY W/AN ORDER OF THE COMMISSIONER.FAILURETO CORRECT & CERTIFY SUMMONS ECB#35423759H & ECB#35379762N.UNAPPROVED,UNSAFE,UNSUITABLE ELECTRICAL EQUIPMENT,APPARATUS,MATERIALS,DEVICES,APP #35634288K | Feb 1, 2022 POP/IN-VIO | $0 |
| Sep 17, 2021 | Boilers CLASS - 2 AIR SEPERATOR LEAKING, NO FITTINGS/THREADS ON EXPANSION TANK RELIEF DISCHARGE PIPING TERMINATION. #39047861N | Oct 15, 2021 POP/IN-VIO | $0 |
| Aug 4, 2021 | Construction CLASS - 1 AN UNLAWFUL ACT. FAILURE TO COMPLY WITH AN ORDER OF THE COMMISSIONER. FAILURE TO CORRECT AND CERTIFY SUMMONS #35346375M AND SUMMONS #35379762N. REMEDY: COMPLY WITH CODE #35583903X | Oct 26, 2021 POP/IN-VIO | $0 |
| Jun 26, 2021 | Construction CLASS - 1 UNLAWFUL ACTS. FAILURE TO COMPLY WITH AN ORDER OF THE COMMISSIONER. FAILURE TO CORRECT AND CERTIFY SUMMONS #35379762N AND SUMMONS #35346375M. REMEDY: COMPLY WITH CODE #35583629M | Sep 14, 2021 POP/IN-VIO | $0 |
| Feb 18, 2020 | Boilers CLASS - 2 BOILER RELIEF VALVE LEAKING, REMOVE THREADS ON DISCHARGE PIPING FOR RELIEF ON EXPANSION TANKS AND BACKFLOW PREVENTER, AUTO VENT LEAKING, CAP OR PLUG ALL OPEN PIPING. RESOLVE VIOLATING CONDITIONS AND SUBMIT A CE #39017762K | Feb 21, 2020 POP/IN-VIO | $0 |
| Feb 18, 2020 | Boilers CLASS - 2 REMOVE THREADS ON RELIEF VALVE DISCHARGE PIPING FOR EXPANSION TANKS AND BACKFLOW PREVENTER, PLUG OR CAP OPEN VALVES, AUTOVENT LEAKING. RESOLVE VIOLATING CONDITIONS AND SUBMIT A CERTIFICATE OF CORRECTION #39017761Z | Feb 21, 2020 POP/IN-VIO | $0 |
| Jan 28, 2020 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE COMPLAINT MANNER- I OBSERVED NO BALL DRIP INSTALLED BETWEEN THE FIRE DEPARTMENT CONNECTION AND THE CHECK VALVE. AS PER BC 2014 4.8.2.2, REPAIR AND/OR REPLACE #39016419Z | Feb 5, 2020 POP/IN-VIO | $0 |
| Oct 17, 2019 | Construction CLASS - 1 UNLAWFUL ACTS UNABLE TO COMPLY WITH AN ORDER OF THE COMMISSIONERS.RECORDS INDICATE NO APPLICATION WAS MADE TO CORRECT AND CERTIFU ECB#36379762N.REMEDY:COMPLY WITH COMMISSIONERS ORDERS. #35460635Z | Dec 31, 2019 POP/IN-VIO | $0 |
| Aug 16, 2019 | Construction CLASS - 1 AN UNLAWFUL ACT FAILURE TO COMPLY WITH AN ORDER OF TEH COMMISSIONER FAILURE TO CORRECT AND CERTIFY SUMMONS #3537962N ISSUED ON 1-8-19 FOR BROKEN RACEWAY ON ROOF TOP COMPLY WITH EC CODE/OBTAIN PERMIT #35445685L | Oct 22, 2019 DEFAULT | $12,500 |
| Jun 24, 2019 | Construction CLASS - 1 UNLAWFUOL ACTS FAILURE TO COMPLY WITH AN ORDER OF THE COMMISSIONER. RECORDS INDICTE NO APPLICATION WAS MADE TO CORRECT AND CERTIFY REMOVALOF VIOLATION CONTAINED IN SUMMONS #35379762N. REMEDY:COMPLY WITH #35423759H | Sep 10, 2019 POP/IN-VIO | $0 |
| Jan 29, 2019 | Boilers CLASS - 2 B254,15,32A,45A,50A,50B. WEIL MCLAIN BOILER MDL #1288: 50A-MOTORIZED LOUVER NOT OPERABLE; 50B-CIRCULATOR LEAKING WATER. RMDY: REPAIR VIOLATING CONDITIONS AND SUBMIT CERTIFICATE OF CORRECITON. #32097846X | Apr 30, 2019 POP/IN-VIO | $0 |
| Jan 8, 2019 | Unknown CLASS - 1 UNAPPROVED/UNSAFE/UNSUITABLE ELECTRICAL EQUIPMENT APPARATUS DEVICES MATERIALS APPLIANCES OR WIRING IN USE. OBSERVED ON ROOFTOP ABOVE STAIRWAY "C" BROKEN RACEWAYS WITH EXPOSED ENERGIZED CONDUCTORS SUPPLIE #35379762N | Mar 26, 2019 POP/IN-VIO | $0 |
| Jan 8, 2019 | Unknown CLASS - 2 FAILURE TO PROVIDE (GFCI)GROUND FAULT CIRCUIT INTERRUPTER PROTECTION AS REQUIRED. OBSERVED RECEPTACLE OUTLET OF THE TGFCI TYPE IN OUTDOOR LOCATIONS ON ROOFTOP AREAS AND REAR COURTYARD. REMEDY:COMPLY WITH #35379763P | Mar 26, 2019 POP/IN-VIO | $0 |
| Sep 13, 2018 | Construction CLASS - 1 UNLAWFUL ACT FAILURE TO COMPLY WITH AN ORDER OF THE COMMISSIONER. RECORDS INDICATE NO APPLICATION WAS MADE TO CORRECT AND CERTIFY REMOV AL OF VIOLATION CONTAINED IN SUMMONS #35346375M. RMDY: COMPLY WITH COM #35346153R | Nov 27, 2018 POP/IN-VIO | $0 |
| Jul 13, 2018 | Unknown CLASS - 2 FAILURE TO PROVIDE EFFECTIVE ELECTRICAL CONTINUITY FOR METAL RACEWAYS CABLE ASSEMBLIES/BOXES/CABINETS/FITTINGS.OBSERVED IN STAIRWELLS THROUGHOUT BLDG INSTALLATION OF EMERGENCY LIGHTS WITH RACEWAYS TERMINATED #35346376Y | Oct 2, 2018 POP/IN-VIO | $0 |
| Jul 13, 2018 | Unknown CLASS - 1 UNAPPROVED/UNSAFE/UNSUITABLE ELECTRICAL EQUIPMENT, APPARATUS, MATERIALS, DEVICES, APPLIANCES OR WIRING IN USE. OBSERVED ON ROOFTOP ABOVE STAIRWAY "C" BROKEN RACEWAYS IT UNSUPPORTED WITH EXPOSED, ENERGIZED #35346375M | Oct 2, 2018 POP/IN-VIO | $0 |
| Jan 23, 2018 | Plumbing CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER; FAILURE TO COMPLY WITH LAW FOR DRAINAGE SYSTEM PER PC 702.1; 27-911. OBSERVED AT DIFFERENT LOCATIONS AROUND THE BUILDING ROOF LEADERS NOT TIED INTO THE DRA #35297849R | Apr 3, 2018 POP/IN-VIO | $0 |
| Jul 17, 2017 | Construction CLASS - 2 FAILURE TO PAINT DEDICATED SPRINKLER PIPING/VALUES IN ACCORDANCE WITH SECTION. OBSERVED IN BOILER ROOM UNPAINTED FIRE SPRINKLER MAIN PIPING.REM: PAINT DEDICATED SPRINKLER PIPING/VALUES AS PER SECTION REQUIREMEN #35286761Z | Oct 17, 2017 POP/IN-VIO | $0 |
| Jul 17, 2017 | Unknown CLASS - 2 FAILURE TO PROVIDE (GFCI) GROUND FAULT CIRCUIT INTERRUPTER PROTECTION AS REQUIRED. OBSERVED RECEPTACLE OUTLETS NOT OF THE GFCI. TYPE IN WET LOCATION AREAS AS REQUIRED IN LAUNDRY ROOM, BOILER ROOM, AND OUTSIDE #35287062Y | Oct 16, 2017 POP/IN-VIO | $0 |
| Jul 17, 2017 | Unknown CLASS - 2 ELECTRICAL WORK W/O A PERMIT. OBSERVED NEW PANELS AND JUNCTION BOXES THROUGHOUT HALLS. ALSO NOTED EXISTING PANELS DISCONNECTED, AND REMOVEDOBSERVED IN ELECTRICAL CLOSETS IN CORRIDORS. ALS NOTED NEW PANELS AND #35287063X | Oct 16, 2017 POP/IN-VIO | $0 |
| Jul 17, 2017 | Unknown CLASS - 2 UNAPPROVED UNSAFE UNSUITABLE ELECTRICAL EQUIPMENT, MATERIALS APPARATUSDEVICE APPLIANCE OR WIRING IN USE. OBSERVED EXPOSED ENERGEIZED WIRES ON ROOFTOP AS WELL AS LIGHT FIXTURES, USED AS RACEWAYS THROUGHOUT BLDG #35287061M | Oct 16, 2017 POP/IN-VIO | $0 |
| Jan 18, 2017 | Construction CLASS - 2 FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER. AT TIME OF INSPECTION I OBSERVED IN THE CELLAR NO TEST TEE INSTALLED ON THE WATER SERVICETO THE BLDG. (DOMESTIC/POTABLE) PER 603.3 OF NY CPC. RMDY: REPAIR AND/ #35225612X | Mar 21, 2017 POP/IN-VIO | $0 |
| Jan 18, 2017 | Construction CLASS - 2 FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER. AT TIME OF INSPECTION I OBSERVED ON THE FIRST FLOOR OF THE BLDG TWO FIRE DEPT CHECK VALVES AND THE PIPING FROM THE FIRE DEPT CONNECTION TO THE CHECK VALVES W/N #35225611Y | Mar 21, 2017 POP/IN-VIO | $0 |
| Oct 26, 2016 | Plumbing CLASS - 2 FAIL TO MAINTAIN BLDG IN CODE COMPLIANT MANNER, REINSTALLATION/MAINTENANCE OF PLUMBING MATERIALS/EQUIPMENT PER PC102.3; 27-902. @ TIME OF INSP, 1:16PM, ON 10/26/16 @ THE ABOVE PLACE OF OCCURENCE ADDRESS I OBSER #35216312J | Jan 24, 2017 POP/IN-VIO | $0 |
| Issued | Violation | Status |
|---|---|---|
| Jan 13, 1997 | LOCAL LAW 10/81 - ELEVATOR #04126 | DOB VIOLATION - ACTIVE |
None open.
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 1, 2026, 1:40 AM ET. BBL 4133070091.