Queens · Block 13307 · Lot 91 · 11434

146-90 Guy R Brewer Blvd

2 floors · 21,000 sq ft · built 1989 · class N2 · owner of record: Nyc Department Of Homeless Services

31open violations
$12,500ECB/OATH penalties owed
0HPD class C (immediately hazardous)
1156dto Gas piping inspection (2029 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 60 days
Keep the report on file (not filed with DOB)
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 13 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1156 days
Next cycle year 2029
Annual boiler inspection (2 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-03-06 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (30) · $12,500 owed
IssuedViolationHearingBalance
Jan 30, 2026Construction CLASS - 2
OBSERVED A POWERFLAME BURNER MODEL WCR3-G-20 SERIAL # 082287282 INSTALLED WITHOUT A PERMIT. OBTAIN THE PROPER PERMIT AND SUBMIT A CERTIFICATE OF CORRECTION.
#39175413X
Feb 6, 2026
POP/IN-VIO
$0
Dec 9, 2022Construction CLASS - 3
FOUND POWERFLAME GAS FIRED BURNER MODEL # WCR3-G-20, SERIAL # 082287282 BEING INSTALLED WITHOUT A PERMIT ON A WEIL MCLAIN MODEL 1288 BOILER. OBTAIN THE PROPER PERMIT AND SUBMIT A CERTIFICATE OF CORRECTION.
#39075415L
Jan 11, 2023
POP/IN-VIO
$0
Nov 22, 2022Construction CLASS - 2
OBSERVED ACTIVE WATER LEAK ON PUMP IN THE BOILER ROOM THAT IS LOCATED IN THE CELLAR. AS PER PC 102.3 MAINTENANCE. INSTALLATIONS, BOTH EXISTING AND NEW, AND PARTS THEREOF SHALL BE MAINTAINED IN PROPER OPERATING
#39074350P
Dec 8, 2022
POP/IN-VIO
$0
Nov 21, 2022Boilers CLASS - 2
CIRCULATOR LEAKING, NO FITTINGS/THREADS ON EXPANSION TANK RELIEF VALVE DISCHARGE PIPING TERMINATION, NO THREADS ON RELIEF PIPING TERMINATION FOR BACKFLOW PREVENTER. CORRECT ALL VIOLATING CONDITIONS AND SUBMIT A
#39074205Z
Dec 8, 2022
POP/IN-VIO
$0
Jan 26, 2022Construction CLASS - 1
UNLAWFUL ACTS FAILURE TO COMPLY W/COMMISSIONER'S ORDERS.RECORDS INDICATE NO APP WAS MADE TO CORRECT OR CERTIFY ECB #'S 35634552X & 35379762NREMEDY:COMPLY W/COMMISSIONER'S ORDERS
#35644907J
May 24, 2022
POP/IN-VIO
$0
Jan 11, 2022Construction CLASS - 2
I OBSERVED ACTIVE WATER LEAK AT THE EXPANSION TANK LOCATED IN THE BOILER ROOM AT CELLAR/BASEMENT LEVEL, BOILER #2 MISSING SITE GLASS AT REAR., REPAIR AND/OR REPLACE
#39054079Z
Feb 11, 2022
POP/IN-VIO
$0
Nov 4, 2021Construction CLASS - 1
UNLAWFUL ACTS.FAILURE TO COMPLY W/AN ORDER OF THE COMMISSIONER.FAILURETO CORRECT & CERTIFY SUMMONS ECB#35423759H & ECB#35379762N.UNAPPROVED,UNSAFE,UNSUITABLE ELECTRICAL EQUIPMENT,APPARATUS,MATERIALS,DEVICES,APP
#35634288K
Feb 1, 2022
POP/IN-VIO
$0
Sep 17, 2021Boilers CLASS - 2
AIR SEPERATOR LEAKING, NO FITTINGS/THREADS ON EXPANSION TANK RELIEF DISCHARGE PIPING TERMINATION.
#39047861N
Oct 15, 2021
POP/IN-VIO
$0
Aug 4, 2021Construction CLASS - 1
AN UNLAWFUL ACT. FAILURE TO COMPLY WITH AN ORDER OF THE COMMISSIONER. FAILURE TO CORRECT AND CERTIFY SUMMONS #35346375M AND SUMMONS #35379762N. REMEDY: COMPLY WITH CODE
#35583903X
Oct 26, 2021
POP/IN-VIO
$0
Jun 26, 2021Construction CLASS - 1
UNLAWFUL ACTS. FAILURE TO COMPLY WITH AN ORDER OF THE COMMISSIONER. FAILURE TO CORRECT AND CERTIFY SUMMONS #35379762N AND SUMMONS #35346375M. REMEDY: COMPLY WITH CODE
#35583629M
Sep 14, 2021
POP/IN-VIO
$0
Feb 18, 2020Boilers CLASS - 2
BOILER RELIEF VALVE LEAKING, REMOVE THREADS ON DISCHARGE PIPING FOR RELIEF ON EXPANSION TANKS AND BACKFLOW PREVENTER, AUTO VENT LEAKING, CAP OR PLUG ALL OPEN PIPING. RESOLVE VIOLATING CONDITIONS AND SUBMIT A CE
#39017762K
Feb 21, 2020
POP/IN-VIO
$0
Feb 18, 2020Boilers CLASS - 2
REMOVE THREADS ON RELIEF VALVE DISCHARGE PIPING FOR EXPANSION TANKS AND BACKFLOW PREVENTER, PLUG OR CAP OPEN VALVES, AUTOVENT LEAKING. RESOLVE VIOLATING CONDITIONS AND SUBMIT A CERTIFICATE OF CORRECTION
#39017761Z
Feb 21, 2020
POP/IN-VIO
$0
Jan 28, 2020Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE COMPLAINT MANNER- I OBSERVED NO BALL DRIP INSTALLED BETWEEN THE FIRE DEPARTMENT CONNECTION AND THE CHECK VALVE. AS PER BC 2014 4.8.2.2, REPAIR AND/OR REPLACE
#39016419Z
Feb 5, 2020
POP/IN-VIO
$0
Oct 17, 2019Construction CLASS - 1
UNLAWFUL ACTS UNABLE TO COMPLY WITH AN ORDER OF THE COMMISSIONERS.RECORDS INDICATE NO APPLICATION WAS MADE TO CORRECT AND CERTIFU ECB#36379762N.REMEDY:COMPLY WITH COMMISSIONERS ORDERS.
#35460635Z
Dec 31, 2019
POP/IN-VIO
$0
Aug 16, 2019Construction CLASS - 1
AN UNLAWFUL ACT FAILURE TO COMPLY WITH AN ORDER OF TEH COMMISSIONER FAILURE TO CORRECT AND CERTIFY SUMMONS #3537962N ISSUED ON 1-8-19 FOR BROKEN RACEWAY ON ROOF TOP COMPLY WITH EC CODE/OBTAIN PERMIT
#35445685L
Oct 22, 2019
DEFAULT
$12,500
Jun 24, 2019Construction CLASS - 1
UNLAWFUOL ACTS FAILURE TO COMPLY WITH AN ORDER OF THE COMMISSIONER. RECORDS INDICTE NO APPLICATION WAS MADE TO CORRECT AND CERTIFY REMOVALOF VIOLATION CONTAINED IN SUMMONS #35379762N. REMEDY:COMPLY WITH
#35423759H
Sep 10, 2019
POP/IN-VIO
$0
Jan 29, 2019Boilers CLASS - 2
B254,15,32A,45A,50A,50B. WEIL MCLAIN BOILER MDL #1288: 50A-MOTORIZED LOUVER NOT OPERABLE; 50B-CIRCULATOR LEAKING WATER. RMDY: REPAIR VIOLATING CONDITIONS AND SUBMIT CERTIFICATE OF CORRECITON.
#32097846X
Apr 30, 2019
POP/IN-VIO
$0
Jan 8, 2019Unknown CLASS - 1
UNAPPROVED/UNSAFE/UNSUITABLE ELECTRICAL EQUIPMENT APPARATUS DEVICES MATERIALS APPLIANCES OR WIRING IN USE. OBSERVED ON ROOFTOP ABOVE STAIRWAY "C" BROKEN RACEWAYS WITH EXPOSED ENERGIZED CONDUCTORS SUPPLIE
#35379762N
Mar 26, 2019
POP/IN-VIO
$0
Jan 8, 2019Unknown CLASS - 2
FAILURE TO PROVIDE (GFCI)GROUND FAULT CIRCUIT INTERRUPTER PROTECTION AS REQUIRED. OBSERVED RECEPTACLE OUTLET OF THE TGFCI TYPE IN OUTDOOR LOCATIONS ON ROOFTOP AREAS AND REAR COURTYARD. REMEDY:COMPLY WITH
#35379763P
Mar 26, 2019
POP/IN-VIO
$0
Sep 13, 2018Construction CLASS - 1
UNLAWFUL ACT FAILURE TO COMPLY WITH AN ORDER OF THE COMMISSIONER. RECORDS INDICATE NO APPLICATION WAS MADE TO CORRECT AND CERTIFY REMOV AL OF VIOLATION CONTAINED IN SUMMONS #35346375M. RMDY: COMPLY WITH COM
#35346153R
Nov 27, 2018
POP/IN-VIO
$0
Jul 13, 2018Unknown CLASS - 2
FAILURE TO PROVIDE EFFECTIVE ELECTRICAL CONTINUITY FOR METAL RACEWAYS CABLE ASSEMBLIES/BOXES/CABINETS/FITTINGS.OBSERVED IN STAIRWELLS THROUGHOUT BLDG INSTALLATION OF EMERGENCY LIGHTS WITH RACEWAYS TERMINATED
#35346376Y
Oct 2, 2018
POP/IN-VIO
$0
Jul 13, 2018Unknown CLASS - 1
UNAPPROVED/UNSAFE/UNSUITABLE ELECTRICAL EQUIPMENT, APPARATUS, MATERIALS, DEVICES, APPLIANCES OR WIRING IN USE. OBSERVED ON ROOFTOP ABOVE STAIRWAY "C" BROKEN RACEWAYS IT UNSUPPORTED WITH EXPOSED, ENERGIZED
#35346375M
Oct 2, 2018
POP/IN-VIO
$0
Jan 23, 2018Plumbing CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER; FAILURE TO COMPLY WITH LAW FOR DRAINAGE SYSTEM PER PC 702.1; 27-911. OBSERVED AT DIFFERENT LOCATIONS AROUND THE BUILDING ROOF LEADERS NOT TIED INTO THE DRA
#35297849R
Apr 3, 2018
POP/IN-VIO
$0
Jul 17, 2017Construction CLASS - 2
FAILURE TO PAINT DEDICATED SPRINKLER PIPING/VALUES IN ACCORDANCE WITH SECTION. OBSERVED IN BOILER ROOM UNPAINTED FIRE SPRINKLER MAIN PIPING.REM: PAINT DEDICATED SPRINKLER PIPING/VALUES AS PER SECTION REQUIREMEN
#35286761Z
Oct 17, 2017
POP/IN-VIO
$0
Jul 17, 2017Unknown CLASS - 2
FAILURE TO PROVIDE (GFCI) GROUND FAULT CIRCUIT INTERRUPTER PROTECTION AS REQUIRED. OBSERVED RECEPTACLE OUTLETS NOT OF THE GFCI. TYPE IN WET LOCATION AREAS AS REQUIRED IN LAUNDRY ROOM, BOILER ROOM, AND OUTSIDE
#35287062Y
Oct 16, 2017
POP/IN-VIO
$0
Jul 17, 2017Unknown CLASS - 2
ELECTRICAL WORK W/O A PERMIT. OBSERVED NEW PANELS AND JUNCTION BOXES THROUGHOUT HALLS. ALSO NOTED EXISTING PANELS DISCONNECTED, AND REMOVEDOBSERVED IN ELECTRICAL CLOSETS IN CORRIDORS. ALS NOTED NEW PANELS AND
#35287063X
Oct 16, 2017
POP/IN-VIO
$0
Jul 17, 2017Unknown CLASS - 2
UNAPPROVED UNSAFE UNSUITABLE ELECTRICAL EQUIPMENT, MATERIALS APPARATUSDEVICE APPLIANCE OR WIRING IN USE. OBSERVED EXPOSED ENERGEIZED WIRES ON ROOFTOP AS WELL AS LIGHT FIXTURES, USED AS RACEWAYS THROUGHOUT BLDG
#35287061M
Oct 16, 2017
POP/IN-VIO
$0
Jan 18, 2017Construction CLASS - 2
FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER. AT TIME OF INSPECTION I OBSERVED IN THE CELLAR NO TEST TEE INSTALLED ON THE WATER SERVICETO THE BLDG. (DOMESTIC/POTABLE) PER 603.3 OF NY CPC. RMDY: REPAIR AND/
#35225612X
Mar 21, 2017
POP/IN-VIO
$0
Jan 18, 2017Construction CLASS - 2
FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER. AT TIME OF INSPECTION I OBSERVED ON THE FIRST FLOOR OF THE BLDG TWO FIRE DEPT CHECK VALVES AND THE PIPING FROM THE FIRE DEPT CONNECTION TO THE CHECK VALVES W/N
#35225611Y
Mar 21, 2017
POP/IN-VIO
$0
Oct 26, 2016Plumbing CLASS - 2
FAIL TO MAINTAIN BLDG IN CODE COMPLIANT MANNER, REINSTALLATION/MAINTENANCE OF PLUMBING MATERIALS/EQUIPMENT PER PC102.3; 27-902. @ TIME OF INSP, 1:16PM, ON 10/26/16 @ THE ABOVE PLACE OF OCCURENCE ADDRESS I OBSER
#35216312J
Jan 24, 2017
POP/IN-VIO
$0
DOB (1)
IssuedViolationStatus
Jan 13, 1997LOCAL LAW 10/81 - ELEVATOR

#04126
DOB VIOLATION - ACTIVE
DOB NOW Safety (0)

None open.

HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 1, 2026, 1:40 AM ET. BBL 4133070091.