Brooklyn · Block 5678 · Lot 49 · 11219

1455 55 Street

6 floors · 30 apartments · 45,600 sq ft · built 1933 · class D1 · owner of record: L B H Equities Inc

20open violations
$0ECB/OATH penalties owed
0HPD class C (immediately hazardous)
67dto Bedbug annual filing

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 67 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 67 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 83 days
Annual
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 45,600 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 188 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 188 days
Annual filing
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 311 days
Registered through 2027-09-01
Gas piping inspection (2027 cycle) Likely applies
Local Law 152 · During 2027
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 12 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2027
in 432 days
Next cycle year 2027
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-04-14 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (0)

None open.

DOB (5)
IssuedViolationStatus
Aug 7, 2026CONSTRUCTION
STRUCTURE RENDERED NON-COMPLIANT DUE TO CONSTRUCTION ACTIVITY AT 1449 55 STREET. EXCAVATION AND INSTALLATION OF THE SUPPORT OF EXCAVATION (SOE) SYSTEM HAVE CAUSED DAMAGE TO THE ADJACENT BUILDING AT 1455 55 STREET, RESULTING IN STRUCTURAL COMPROMISE ALONG THE ENTIRE C-LINE, INCLUDING THE APARTMENTS A
#26-01958
DOB VIOLATION - ACTIVE
Aug 7, 2026CONSTRUCTION
EMERGENCY WORK ORDER.AS A RESULT OF CONSTRUCTION,SUPPORT OF EXCAVATION @ADJ 1449 555ST CONSTRUCTION,THE 1455 BLDG WAS DMGD.EXP2 EXT CORRIDOR CRCKD;EXP2 BEARNG WALL CRCKD/BULGD@1STFL &UP TO PARAPET.OWNR TO IMMED RTAIN NYPE DOB REG GC TO 1.SBMT MEANS&METHDS TO FEU FOR REVIEW/APPRVL, 2.UPN APPRVL IMMED
#FEU31201KR
DOB VIOLATION - ACTIVE
Aug 7, 2026CONSTRUCTION
FAILURE TO MAINTAIN BLDG IN A SAFE CONDITION.AS A RESULT OF CNSTRCTN ACTIVITIES@ADJ 1449 55ST,THE 1455 ST BLDG WAS DMGD.EXP2 EXT CORRIDOR CRCKD.EXP2 BEARNG WALL CRCKD.EXP1&3WALLS FOR C LINE APTS.OWNR TO RTAIN NYSPE TO EVAL THE ENT BLDG&RPAIR UNDR PRMT STRT WRK BY 10/5/25 & COMPLETE/SIGN OFF BY 12/14
#FEU31202KR
DOB VIOLATION - ACTIVE
Aug 6, 2026CONSTRUCTION
STRUCTURE RENDERED NON-COMPLIANT. AT TIME OF INSPECTION OBSERVED LEFT SIDE GROUND LEVEL TEMP SHORING INSTALLED AT EGRESS PASSAGEWAY. AT WALKWAY & FLOORS 1-6 VERTICAL CRACKS CAUSED BY CONSTRUCTION SITE OPERATIONS AT ADJACENT PROPERTY(1449 55 STREET).
#26-01946
DOB VIOLATION - ACTIVE
Aug 16, 1993LOCAL LAW 62/91 - BOILERS

#34280
DOB VIOLATION - ACTIVE
DOB NOW Safety (2)
IssuedViolationStatus
Oct 25, 2024Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2023 External Inspection Affirmation of Correction for LP Device
Active
Oct 11, 2024Elevators FTC-VT-PER-CO
Violation Issued-Failure To File 2023 Periodic Inspection Affirmation of Correction
Active
HPD (13) · C 0 · B 11 · A 2
IssuedClassViolationCorrect by
Jun 30, 2008BD26-10.01 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD & SLATE ROOF COPULA SOUTHWEST ROOF.Aug 4, 2008
Jun 30, 2008BD26-10.01 ADM CODE PROPERLY SECURE THE LOOSE HANDRAIL STAIRS EAST PASSAGEWAY.Aug 4, 2008
Jun 30, 2008BD26-10.01 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE LOOSE SLATE ORNAMENTAL CANOPY EXTERIOR FRONT OF BLDG.Aug 4, 2008
Jun 30, 2008B§ 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES 6 STY FRONT SOUTH.Aug 4, 2008
Jun 30, 2008B§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WALL WINDOW AREA INTERMEDIATE LANDING 5 TO 6 STY PUBLIC HALL.Aug 4, 2008
Jun 30, 2008B§ 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE PUBLIC HALL BULKHEAD TO ROOF.Aug 4, 2008
Oct 20, 2006A§ 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION STEEL PORCH ERACTED 3RD TO 4TH STORY BUILDING FRONTJan 28, 2007
Dec 10, 2004BApt 2C · § 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 2C, 2nd STORYJan 19, 2005
Oct 4, 2001BApt 3C · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF EVIDENCE OF WATER LEAK CEILING BATHROOM AND IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 3C, 3rd STORY, 1st APARTMENT FROM WEST AT NORTHNov 13, 2001
Oct 4, 2001BApt 3C · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 3C, 3rd STORY, 1st APARTMENT FROM WEST AT NORTHNov 13, 2001
May 17, 1994A§ 27-2014 ADM CODE AND DEPT. RULES AND REGULATIONS. SCRAPE AND REMOVE RUST SCALES AND PAINT WITH 2 COATS OF PAINT ALL STYS ALL PARTS ALL BALCONIES FIRE ESCAPESSep 2, 1994
Jul 3, 1990B§ 27-2010, 2011, 2012 ADM CODE CLEANSE AND DISINFECT TO THE SATISFACTION OF THIS DEPARTMENT AFTER REMOVING THE RUBBISH INCINERATOR CLOSETS ALL STYS PUBLIC HALLS.Aug 20, 1990
Jul 3, 1990B§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WALLS INCINERATOR CLOSET 1 STY PUBLIC HALL.Aug 20, 1990

Issued in the last 120 days

DateSourceWhatNow
Aug 7, 2026DOBCONSTRUCTION: STRUCTURE RENDERED NON-COMPLIANT DUE TO CONSTRUCTION ACTIVITY AT 1449 55 STREET. EXCAVATION AND INSTALLATION OF THE SUPPORT OF EXCAVATION (SOE) SYSTEM HAVE CAUSED DAMAGE TO THE ADJACENT BUILDING AT 1455 55 STREET, RESULTING IN STRUCTURAL COMPROMISE ALONG THE ENTIRE C-LINE, INCLUDING THE APARTMENTS AOpen
Aug 7, 2026DOBCONSTRUCTION: EMERGENCY WORK ORDER.AS A RESULT OF CONSTRUCTION,SUPPORT OF EXCAVATION @ADJ 1449 555ST CONSTRUCTION,THE 1455 BLDG WAS DMGD.EXP2 EXT CORRIDOR CRCKD;EXP2 BEARNG WALL CRCKD/BULGD@1STFL &UP TO PARAPET.OWNR TO IMMED RTAIN NYPE DOB REG GC TO 1.SBMT MEANS&METHDS TO FEU FOR REVIEW/APPRVL, 2.UPN APPRVL IMMEDOpen
Aug 7, 2026DOBCONSTRUCTION: FAILURE TO MAINTAIN BLDG IN A SAFE CONDITION.AS A RESULT OF CNSTRCTN ACTIVITIES@ADJ 1449 55ST,THE 1455 ST BLDG WAS DMGD.EXP2 EXT CORRIDOR CRCKD.EXP2 BEARNG WALL CRCKD.EXP1&3WALLS FOR C LINE APTS.OWNR TO RTAIN NYSPE TO EVAL THE ENT BLDG&RPAIR UNDR PRMT STRT WRK BY 10/5/25 & COMPLETE/SIGN OFF BY 12/14Open
Aug 6, 2026DOBCONSTRUCTION: STRUCTURE RENDERED NON-COMPLIANT. AT TIME OF INSPECTION OBSERVED LEFT SIDE GROUND LEVEL TEMP SHORING INSTALLED AT EGRESS PASSAGEWAY. AT WALKWAY & FLOORS 1-6 VERTICAL CRACKS CAUSED BY CONSTRUCTION SITE OPERATIONS AT ADJACENT PROPERTY(1449 55 STREET).Open

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 25, 2026, 8:40 AM ET. BBL 3056780049.

Look up another building