Manhattan · Block 2149 · Lot 276 · 10040

145 Ft George Avenue

1 floors · 7,760 sq ft · built 1940 · class K1 · owner of record: Nissan 1662 St. Nicholas Ave, Llc

3open violations
$0ECB/OATH penalties owed
0HPD class C (immediately hazardous)
416dto Gas piping inspection (2027 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 51 days
Keep the report on file (not filed with DOB)
Gas piping inspection (2027 cycle) Likely applies
Local Law 152 · During 2027
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 12 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2027
in 416 days
Next cycle year 2027

Open violations

ECB / OATH (0)

None open.

DOB (2)
IssuedViolationStatus
Jan 26, 2022CONSTRUCTION
EMERGENCY WORK. REMEDY: OWNER TO PROCEED WITH IMMED EMERGENCY STAB OF THE R/W ADJ THE PUBLIC SIDEWALK. OWNER TO IMMED RETAIN A LIC PROF ENG'R TO PREPARE EMERGENCY STAB DWGS. DWGS TO BE PROVIDED TO THE R/W UNIT BY 2/8/2022. ALL WORK TO BE DONE UNDER PE SUPERV. FILE FOR PERMIT WITHING 48 HRS OF COMMEN
#11202BH
DOB VIOLATION - ACTIVE
Jan 26, 2022CONSTRUCTION
FTM RETAINING WALL IN A SAFE CONDITION. AT TIME OF INSPECTION OBSERVED THE RETAINING WALL LOCATED ALONG FT GEORGE AVE IS EXTREMELY DETERIORATED AND READY TO COLLAPSE ON THE SIDEWALK. REMEDY: IMMED RETAIN A DESING PROF TO DESIGN AND PERMIT A REPLACEMENT RETAINIGN WALL ALONG THE STABILIZATION & DEMO O
#RW11201BH
DOB VIOLATION - ACTIVE
DOB NOW Safety (1)
IssuedViolationStatus
Aug 11, 2023Elevators FTF-VT-CAT1-CO
Violation Issued-Failure To File 2021 Cat1 Test Report
Active
HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 9, 2026, 6:47 PM ET. BBL 1021490276.