Manhattan · Block 1304 · Lot 26 · 10017

145 East 49 Street

10 floors · 37,371 sq ft · built 1916 · class HS · owner of record: 145 East 49th Street

3open violations
$20,000ECB/OATH penalties owed
0HPD class C (immediately hazardous)
43dto Gas piping inspection (2026 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 6 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 43 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 43 days
Keep the report on file (not filed with DOB)
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 37,371 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 164 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 164 days
Annual filing
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-09-01 (Accepted). Agency page

On file2026 reports accepted
Facade inspection report (Cycle 10A) Applies
Local Law 11 / FISP · Feb 21, 2025 to Feb 21, 2027
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 4, 5, 6 or 9 are in sub-cycle 10A. DOB facade records for this building show $10,500 in late-filing or failure-to-file penalties. Agency page

On fileCycle 10 filing on record: SAFE (2025-11-20)

Open violations

ECB / OATH (4) · $20,000 owed
IssuedViolationHearingBalance
May 8, 2025Unknown CLASS - 1
FAILURE TO REPORT TO DEPARTMENT WITHIN 3 BUSINESS DAYS FOR REQUIRED 16 ITEMS AFTER INCIDENT DATED ON 3/20/2025, UNDER PERMIT # M01090865. THE DEPARTMENT DID NOT RECEIVED INFORMATION REQUIRED BY SECTION 28-103.2
#39539979J
Feb 3, 2026
IN VIOLATION
$10,000
Mar 21, 2025Unknown CLASS - 2
AT THE TIME OF INSPECTION ACTIVE SITE, I OBSERVED PIPE SCAFFOLD INSTALLED ON SHED AT EXPOSURE#1 NOT MAINTAINED AS PER CODE. I OBSERVED THERE ARE 2 TO 3 INCH GAPS BETWEEN PLATFORMS PLANKS THROUGHOUT SCAFFOLD CRE
#39538250K
Dec 2, 2025
IN VIOLATION
$2,500
Mar 21, 2025Unknown CLASS - 2
AT THE TIME OF INSPECTION ACTIVE CONSTRUCTION SITE, I OBSERVED SCAFFOLD PLATFORMS NOT MAINTAINED AS PER CODE AT THE 9TH FLOOR LEVEL AT EXPOSURE#1 OF BUILDING EXTERIOR. I OBSERVED POINT LOADING,IMPROPER STORAGE
#39538257N
Dec 2, 2025
IN VIOLATION
$2,500
Mar 20, 2025Construction CLASS - 1
AT THE TIME OF INCIDENT IT WAS REPORTED BY NYCEM THAT A WORKER FELL 5 STORIES FROM A SUPPORTED SCAFFOLD AT EXPOSURE#1 AND WAS TRANSPORTED TO BELLEVUE HOSPITAL WITH UNKNOWN INJURIES THE CONTRACTOR FAILED TO NOT
#39538214N
Dec 2, 2025
IN VIOLATION
$5,000
DOB (1)
IssuedViolationStatus
May 31, 2018NO REPORT AND / OR LATE FILING (FACADE)
FAILED TO FILE FISP CYCLE 8A TECHNICAL REPORT BY 02/21/2017
#01085
DOB VIOLATION - ACTIVE
DOB NOW Safety (0)

None open.

HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 18, 2026, 5:13 AM ET. BBL 1013040026.