Brooklyn · Block 1002 · Lot 54 · 11215

145 9 Street

3 floors · 5 apartments · 4,555 sq ft · built 1866 · class C2 · owner of record: Liharevic Muhamet

35open violations
$2,500ECB/OATH penalties owed
7HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueRegistration expired 2025-09-01
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 6 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 68 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 68 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 68 days
Annual
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2023-07-27 (Accepted). Agency page

Dec 31, 2026
in 68 days
1 of 1 without an accepted 2026 report yet
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 84 days
Annual

Open violations

ECB / OATH (2) · $2,500 owed
IssuedViolationHearingBalance
Sep 9, 2026Construction CLASS - 1
FAILURE TO COMPLY WITH COMMISSIONER'S ORDER FOR DOB VIO23-03363., COMPLY WITH COMMISSIONER'S ORDER
#39203488X
Nov 18, 2026
PENDING
$2,500
Sep 21, 2011Construction CLASS - 1
OCCUPANCY CONTRARY TO THAT ALLOWED BY BUILDING DEPT RECORDS. H.P.D. RECORDS FOR MDR #338108 ALONG WITH I-CARDS STATES THAT BUILDING AT FRONTTO BE LEGALLY OCCUPIED AS 3 STORIES,6 CLASS'A' DWELLINGS,(0) "B" UNITS
#34916922H
Feb 13, 2012
IN VIOLATION
$0
DOB (7)
IssuedViolationStatus
Nov 14, 2025LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
#14590
DOB VIOLATION - ACTIVE
Dec 22, 2023CONSTRUCTION
FTM-FIRE @143 9ST ON 12/21/23.ROOF HAD FIRE CUTS ALONG EXP2ROOF JOISTS W/FIRE/SMOKE DMG.EXP2 WALL @3FL PARTY DTACHD APPRX 10'WW/EXP2 WOOD BEARNG STUDS &ROOF FRAMNG FIRE DMGD.EXP2 WALL TEMP BOARDED.OWNR RTAIN NYSPE-EVAL ENTIRE BLDG &FILE RPR DWGS W/DOB.PRMNT RPRS TO STRT BY 2/12/24 & COMPLTD/SIGND OF
#FEU30603PN
DOB VIOLATION - ACTIVE
Dec 21, 2023CONSTRUCTION
FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. STRUCTURE RENDERED NON-COMPLIANT DUE TO FDNY ACTIVES AND WATER DAMAGE.
#23-03364
DOB VIOLATION - ACTIVE
Dec 21, 2023CONSTRUCTION
FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. OWNER TO HIRE NYSPE TO SUBMIT REPORT TO ERT INSPECTIONS@BUILDINGS.NYC.GOV WITHIN 5 DAYS, ADDRESSING ALL CONDITIONS W/PLANS, PHOTOS, RECOMMENDING TIME FRAME AND REPAIRS TO BE COMPLETED.
#23-03363
DOB VIOLATION - ACTIVE
May 15, 2014LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT
#10236
DOB VIOLATION - ACTIVE
Dec 14, 2011FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00249
DOB VIOLATION - ACTIVE
Aug 16, 1993LOCAL LAW 62/91 - BOILERS

#19405
DOB VIOLATION - ACTIVE
DOB NOW Safety (5)
IssuedViolationStatus
Nov 14, 2025Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
Active
Oct 31, 2025Gas Piping - LL152 FTF-PL-PER
Cycle 1, Sub-cycle C (premises is in Community District 6)
Active
Oct 31, 2025Gas Piping - LL152 FTF-PL-PER
Cycle 1, Sub-cycle C (premises is in Community District 6)
Active
May 15, 2014Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT
Active
Dec 14, 2011AEUHAZ FTC-AEU-HAZ
Active
HPD (21) · C 7 · B 7 · A 6
IssuedClassViolationCorrect by
Nov 19, 2025I§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID R—
Apr 30, 2026A(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.Aug 3, 2026
Jul 19, 2021BApt 2L · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 2L, 2nd STORY, 1st APARTMENT FROM WEST AT NORTHAug 23, 2021
Jul 19, 2021BApt 2L · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 2L, 2nd STORY, 1st APARTMENT FROM WEST AT NORTHAug 23, 2021
Jul 19, 2021CApt 2L · § 27-2056.7, 27-2056.8, 27-2056.9 ADM CODE -CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS DURING PERIOD OF UNIT VACANCY BY PERFORMING ACTIVITIES NECESSARY TO ABATE TESTED LEAD-BASED PAINT FROM REQUIRED WINDOW AND/OR DOOR FRICTION SURFACES FOR APARTMENT AND MAKE FLOORS SMOOTH AAug 12, 2021
Jul 19, 2021BApt 2L · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF LOCKABLE SLIDE BOLT LOCK INSTALED AT 2ND DOOR FROM NORTH AT EAST IN THE 4th ROOM FROM EAST LOCATED AT APT 2L, 2nd STORY, 1st APARTMENT FROM WEST AT NORTHAug 23, 2021
Jul 19, 2021CApt 2L · § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE GLASS PANE AT UPPER SASH AT 1ST WINDOW FROM NORTH AT EAST IN THE KITCHEN LOCATED AT APT 2L, 2nd STORY, 1st APARTMENT FROM WEST AT NORTHJul 25, 2021
Jul 19, 2021CApt 2L · § 27-2005, 2007 HMC: REMOVE THE ILLEGAL DOUBLE CYLINDER KEY OPERATED LOCKING DEVICE AT DOOR .. IN THE ENTRANCE LOCATED AT APT 2L, 2nd STORY, 1st APARTMENT FROM WEST AT NORTHJul 25, 2021
Jul 19, 2021CApt 2L · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE SPRING BALANCE AT LOWER SASH AT 1ST WINDOW FROM NORTH AT EAST IN THE KITCHEN LOCATED AT APT 2L, 2nd STORY, 1st APARTMENT FROM WEST AT NORTHJul 25, 2021
Jul 16, 2021CApt 2L · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) SOUTH WALL IN THE 4th ROOM FROM EAST LOCATED AT APT 2L, 2nd STORY, 1st APARTMENT FROM Aug 9, 2021
Jul 16, 2021BApt 2L · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE KITCHEN LOCATED AT APT 2L, 2nd STORY, 1st APARTMENT FROM WEST AT NORTHAug 20, 2021
Jul 16, 2021AApt 2L · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE 1st DOOR FROM EAST AT SOUTH WALL IN THE KITCHEN LOCATED AT APT 2L, 2nd STORY, 1st APARTMENT FROM WEST AT NORTHOct 19, 2021
Jul 16, 2021AApt 2L · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE 1st DOOR FRAME FROM NORTH AT EAST WALL IN THE 3rd ROOM FROM EAST LOCATED AT APT 2L, 2nd STORY, 1st APARTMENT FROM WEST AT NORTHOct 19, 2021
Jul 16, 2021B§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE WOOD TREADS 1ST, 2ND, 3RD, 4TH, 5TH AND 6TH UP FROM THE BOTTOM AT PUBLIC HALL, 2nd STORYAug 20, 2021
Jul 16, 2021CApt 2L · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) NORTH WALL, SOUTH WALL IN THE 3rd ROOM FROM EAST LOCATED AT APT 2L, 2nd STORY, 1st APAAug 9, 2021
Jul 16, 2021CApt 2L · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st DOOR FRAME FROM EAST AT SOUTH WALL, 1st WINDOW FRAME FROM NORTH AT EAST WALL IN THAug 9, 2021
Jun 17, 2013AApt 1L · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILES IN THE BATHROOM LOCATED AT APT 1L, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTSep 20, 2013
Jun 17, 2013A§ 27-2005 ADM CODE REPLACE WITH NEW THE MISSING DOOR KNOB AT BUILDING ENTRANCE DOOR , 1st STORYSep 20, 2013
Jun 17, 2013BApt 1L · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING LOCATED AT APT 1L, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTJul 22, 2013
Jun 17, 2013AApt 1L · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING AND NORTH WALL IN THE BATHROOM LOCATED AT APT 1L, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTSep 20, 2013
Jun 17, 2013BApt 1L · § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF ROACHES LOCATED AT APT 1L, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTJul 22, 2013

Issued in the last 120 days

DateSourceWhatNow
Sep 9, 2026ECBConstruction: FAILURE TO COMPLY WITH COMMISSIONER'S ORDER FOR DOB VIO23-03363., COMPLY WITH COMMISSIONER'S ORDEROpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 24, 2026, 2:27 AM ET. BBL 3010020054.