Brooklyn · Block 3440 · Lot 32 · 11207

144 Cooper Street

2 floors · 5 apartments · 3,933 sq ft · built 1925 · class C2 · owner of record: 144 Cooper St Gr Llc

30open violations
$17,150ECB/OATH penalties owed
2HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 4 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 69 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 69 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 69 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 85 days
Annual
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueNo current registration found

Open violations

ECB / OATH (10) · $17,150 owed
IssuedViolationHearingBalance
Jun 8, 2026Construction CLASS - 2
GC FAIL TO FILE CERTIFICATE OF CORRECTION WITH THE DOB NO CORRECTIVE MEASURES ON RECORD FOR VIOLATION# 39550191L ISSUED 02/10/26.
#39555226P
Aug 12, 2026
IN VIOLATION
$625
Apr 14, 2026Construction CLASS - 2
AT OF REINSPECTION OF A CLASS #1 SUMMONS ENDING IN #50191L THAT WAS CITED FOR HOUSEKEEPING, I OBSERVED SITE CLOSED WITH NO RECORDS OF CERTIFICATE OF CORRECTION FILED UPON REVIEWING THE DEPARTMENT SYSTEM. COMPLY
#39552953H
Jun 24, 2026
IN VIOLATION
$625
Feb 10, 2026Unknown CLASS - 2
B.C 3301.5 OBSERVED ON THE SECOND FL A HOLE OPENING TEMPORARY COVERED WITH MATERIAL IN A UNSAFE MANNER NOT DESIGNED TO PROTECT OR COVER AN OPENING THAT WIDE. A TYPE OF MAKESHIFT PLATFORM WAS COVERING THE HOLE.
#39550194R
Jun 3, 2026
IN VIOLATION
$2,500
Feb 10, 2026Unknown CLASS - 2
B.C 3307.7.1 LOCATION OF FENCE. OBSERVED AT THE REAR OF THE BUILDING MISSING THE 8' HIGH FENCE TO PREVENT THE PUBLIC ACCESS INTO THE BUILDING. THE BUILD IS AT GRADE AND THE BACKDOOR IS NOT LOCKED TO PREVENT ACC
#39550193P
Jun 3, 2026
IN VIOLATION
$2,500
Feb 10, 2026Unknown CLASS - 2
B.C BC 3301.2 & 27-1009(A). IN NUMEROUS LOCATIONS OBSERVED AREAS THAT WERE UNPROTECTED WITH A ADEQUATE GUARDRAIL SYSTEM. THE OPENINGS ARE APPROX. 3' OR GREATER AND THE FALL WAS OVER 6' DOWN. STOP ALL WORK ENTIR
#39550192N
Jun 3, 2026
IN VIOLATION
$2,500
Feb 10, 2026Construction CLASS - 2
THE ROOF OF THE BUILDING IS NOT COMPLETED. THERE IS STILL WORK TO BE DONE AROUND THE PARAPET AND EXPO#2 FACADE STILL HAS EXTERIOR WORK TO COMPLETE. A SUSPENDED SCAFFOLD IS INSTALLED AT THAT EXPO. NO OVERHEAD PR
#39550195Z
Jun 3, 2026
IN VIOLATION
$2,400
Feb 10, 2026Unknown CLASS - 2
OBSERVED AT EXPO#2 AND #4 MISSING AND INADEQUATE ROOF PROTECTION. THE ROOF OF THE BUILDING IS NOT COMPLETE THE BULKHEAD AND PARAPET MISSING COOPING. AND EXPO#2 FACADE IS NOT COMPLETE WITH STUCCO WORK. ROOF PRO
#39550189M
Jun 3, 2026
IN VIOLATION
$2,500
Feb 10, 2026Construction CLASS - 1
OBSERVED THROUGHOUT ENTIRE SITE. BAD HOUSEKEEPING CONDITIONS. PILES OF MATERIAL LEFT STORED ONSITE POSSIBLE RODENT AND FIRE HAZARD CONDITIONS. SLIP AND TRIP HAZARDS IN THE ROOMS AND MATERIAL STORED ON THE STAIR
#39550191L
Jun 3, 2026
IN VIOLATION
$2,500
Feb 10, 2026Construction CLASS - 2
OBSERVED THE MAIN DOOR INSTALLED WITH THE CONSTRUCTION FENCE NOT IN COMPLIANCE TO CODE. DOOR SWINGS OUTWARD INTO THE PUBLIC WALKING SPACE. DOOR CAN SWING INTO A PEDESTRIAN WALKING BY CAUSING INJURY. B.C 3307.7.
#39550190J
Jun 3, 2026
IN VIOLATION
$1,000
Aug 23, 2009Construction CLASS - 1
OCCUPANCY CONTRARY TO THAT ALLOWED BY C OF O AND DEPT OF BLDG RECORDS.CLASS A APT CREATING AT CELLAR. PARTITION ERECTED CREATING ROOM. KITCHEN AND BATHROOM FIXTURES PRESENT. REM: DISCONTINUE ILLEGAL USE OF AMEN
#34748256P
Nov 2, 2009
WRITTEN OFF
$0
DOB (0)

None open.

DOB NOW Safety (0)

None open.

HPD (25) · C 2 · B 20 · A 2
IssuedClassViolationCorrect by
Aug 31, 2009ISECTION 27-2142 ADM CODE - THE PREMISES OR APTS. HAVE BEEN VACATED BY THE DEPARTMENT AND CANNOT BE REOCCUPIED UNTIL SO ORDERED AFTER PROOF OF COMPLIANCE FOR CELLAR APT.—
Aug 24, 2021BApt 2 · § 27-2073 ADM CODE - PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 2, 2nd STORY, APARTMENT AT EASTSep 28, 2021
Aug 24, 2021BApt 2 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... CEILING CEILING 5 SQUARE FEET, WEST WALL 5 SQUARE FEET IN THE KITCHEN LOCATED AT APT 2, 2nd STORY, APARTMENT AT EASTSep 28, 2021
Aug 24, 2021B§ 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING DOOR TO ROOF AT PUBLIC HALL, 2nd STORYSep 28, 2021
Aug 24, 2021BApt 2 · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). REPLACE IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STORY, APARTMENT AT EASTSep 28, 2021
Aug 24, 2021BApt 2 · § 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE MECHANICAL AIR VENT AT CEILING IN THE BATHROOM LOCATED AT APT 2, 2nd STORY, APARTMENT AT EASTSep 28, 2021
Aug 24, 2021BApt 2 · § 27-2024 ADMIN. CODE: PROVIDE ADEQUATE SUPPLY OF COLD WATER FOR THE FIXTURES AT WASH BASIN AND SHOWER IN THE BATHROOM LOCATED AT APT 2, 2nd STORY, APARTMENT AT EASTSep 28, 2021
Aug 24, 2021BApt 2 · § 27-2024 ADMIN. CODE: PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES AT WASH BASIN AND SHOWER IN THE BATHROOM LOCATED AT APT 2, 2nd STORY, APARTMENT AT EASTSep 28, 2021
Aug 24, 2021BApt 2 · § 27-2005 ADMIN. CODE: PROPERLY SECURE THE LOOSE WASH BASIN IN THE BATHROOM LOCATED AT APT 2, 2nd STORY, APARTMENT AT EASTSep 28, 2021
Aug 24, 2021BApt 2 · § 27-2005 ADMIN. CODE: PROPERLY SECURE THE LOOSE DOOR AT SHOWER IN THE BATHROOM LOCATED AT APT 2, 2nd STORY, APARTMENT AT EASTSep 28, 2021
Aug 24, 2021BApt 2 · § 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE BATHROOM LOCATED AT APT 2, 2nd STORY, APARTMENT AT EASTSep 28, 2021
Aug 24, 2021BApt 2 · § 27-2005 ADMIN. CODE: REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 2, 2nd STORY, APARTMENT AT EASTSep 28, 2021
Aug 24, 2021BApt 2 · § 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT EAST, NORTH AND SOUTH WALLS AT STAND UP SHOWER IN THE BATHROOM LOCATED AT APT 2, 2nd STORY, APARTMENT AT EASTSep 28, 2021
Aug 24, 2021BApt 2 · § 27-2024 ADMIN. CODE: PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES AT SINK IN THE KITCHEN LOCATED AT APT 2, 2nd STORY, APARTMENT AT EASTSep 28, 2021
Aug 24, 2021BApt 2 · § 27-2024 ADMIN. CODE: PROVIDE ADEQUATE SUPPLY OF COLD WATER FOR THE FIXTURES AT SINK IN THE KITCHEN LOCATED AT APT 2, 2nd STORY, APARTMENT AT EASTSep 28, 2021
Aug 24, 2021BApt 2 · § 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR ALL WALLS AND CEILING IN THE KITCHEN LOCATED AT APT 2, 2nd STORY, APARTMENT AT EASTSep 28, 2021
Aug 24, 2021BApt 2 · § 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE KITCHEN LOCATED AT APT 2, 2nd STORY, APARTMENT AT EASTSep 28, 2021
Aug 24, 2021AApt 2 · § 27-2005 ADMIN. CODE: REFIT DOOR AT FRONT ENTRANCE LOCATED AT APT 2, 2nd STORY, APARTMENT AT EASTNov 27, 2021
Aug 24, 2021A§ 27-2005 ADMIN. CODE: REFIT DOOR AT FRONT ENTRANCE TO BUILDINGNov 27, 2021
Aug 24, 2021BApt 2 · § 27-2005 ADMIN. CODE: REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN UNIFORM COLOR ALL WALLS AND CEILING IN THE BATHROOM LOCATED AT APT 2, 2nd STORY, APARTMENT AT EASTSep 28, 2021
Aug 24, 2009BSECTION 27-2073 ADM CODE - DISCONTINUE UNLAWFUL COOKING SPACE OR FILE PLANS AND APPLICATION WITH THIS DEPARTMENT TO LEGALIZE SAME, IF LAWFULLY FEASIBLE GAS RANGE AT CELLARSep 28, 2009
Aug 24, 2009CApt 1 · SECTION 27-2073 ADM CODE - PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES RANGE IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM EAST AT SOUTHAug 30, 2009
Aug 24, 2009CApt 1 · SECTION 27-2031 ADMIN. CODE: PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM EAST AT SOUTHAug 30, 2009
Aug 24, 2009BApt 1 · SECTION 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM EAST AT SOUTHSep 28, 2009
Aug 24, 2009BSECTION 27-2087 ADM CODE - DISCONTINUE USE OF ROOMS FOR LIVING, DISCONNECT PLUMBING FIXTURES WHERE ILLEGAL AND PROPERLY SEAL PIPE CONNECTIONS KITCHEN SINK, WASH BASIN , WATER CLOSET AND BATHTUB AT CELLARSep 28, 2009

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 23, 2026, 11:43 PM ET. BBL 3034400032.