6 floors · 119 apartments · 118,992 sq ft · built 1960 · class D4 · owner of record: Imperial Sanford Owners Inc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 43 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 43 days | Annual |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-07-11 (Accepted). Agency page | Dec 31, 2026 in 43 days | 1 of 1 without an accepted 2026 report yet |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 59 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 118,992 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 164 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 164 days | Annual filing |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 287 days | Registered through 2027-09-01 |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 7 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1139 days | Next cycle year 2029 |
| Energy audit and retro-commissioning (2034) Likely applies Local Law 87 · Calendar year 2034 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 5374). Agency page | Dec 31, 2034 in 2965 days | Next due 2034 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Sep 26, 2024 | Elevators CLASS - 1 ENTIRE DEVICE INOPRATIVE REPAIR #39125849L | Dec 3, 2024 ADMIT/IN-VIO | $0 |
| Nov 14, 2023 | Construction CLASS - 1 FAILURE TO OBEY A VACATE ORDER FROM THE COMMISSIONER PER 28-207.4 NOTE: RESPONDENT FAILURE TO OBEY A VACATE ORDER FROM THE COMMISSIONER PER 28-207.4 NOTE: RESPONDENT FAILURE TO COMPLY WITH COMMISSIONER'S VACATE #35675408R | Jun 11, 2024 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| Dec 11, 2024 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00691 | DOB VIOLATION - ACTIVE |
| May 2, 2024 | FAILURE TO BENCHMARK FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 #01382 | DOB VIOLATION - ACTIVE |
| Oct 13, 2023 | CONSTRUCTION PARTIAL VACATE ORDER.AS OBSERVED ON 10/13/23 BY FACADE INSPECTOR,THERE WERE CRACKED&SPALLING/BALCONY SLAB&CURES@ BOTH EXP#1NS.DUE TO THESE COND.ALL BALCONIES ON BOTH EXP#1NS&GARAGE ROOFON EXP#3S ARE TO BE VACATED. REMEDY:VACATE ALL BALCONNIES&TERRACES OF EXP#1N&3S&THE GARAGE ROOF ON EXP#3S WOU #FA40702AM | DOB VIOLATION - ACTIVE |
| Oct 13, 2023 | CONSTRUCTION EMERGENCY WORK ORDER DUE TO DEFECTIVE FACADE AT EXPOSURES#1&3(NORTH& SOUTH ELEVATION)OBSERVED SPALLED CONCRETE BALCONIES AT LINE.C,D,&N LEANING PARAPET WALL ENTIRE NORTH FACADE.REMEDY:IMMEDIATELY PROVIDE SAFETY MEASURES AT EX#1&3 TO SECURE/PROTECT THE PUBLIC AND REMONE ALL LOOSE MATERIALS.IMMED.RETA #FA40701AM | DOB VIOLATION - ACTIVE |
| Jun 20, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION #11229 | DOB VIOLATION - ACTIVE |
| Jun 20, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION #32817 | DOB VIOLATION - ACTIVE |
| Aug 2, 2020 | FAILURE TO BENCHMARK FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 #01706 | DOB VIOLATION - ACTIVE |
| May 16, 2020 | ELEVATOR CEASE USE #9027H681629 | DOB VIOLATION - ACTIVE |
| May 16, 2020 | ELEVATOR #9027/681630 | DOB VIOLATION - ACTIVE |
| May 2, 2020 | FAILURE TO BENCHMARK FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 #01706 | DOB VIOLATION - ACTIVE |
| Apr 6, 2018 | LOW PRESSURE BOILER VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2016 INSPECTION REPORT #15056 | DOB VIOLATION - ACTIVE |
| Nov 14, 2016 | (OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2014 CAT 1 INSP/TST #07519 | DOB VIOLATION - ACTIVE |
| Nov 14, 2016 | (OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2014 CAT 1 INSP/TST #07518 | DOB VIOLATION - ACTIVE |
| Jun 3, 2013 | FAILURE TO BENCHMARK FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 #01682 | DOB VIOLATION - ACTIVE |
| Jan 1, 2012 | FAILURE TO BENCHMARK FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 #02726 | DOB VIOLATION - ACTIVE |
| Dec 31, 2009 | LOW PRESSURE BOILER #22885 | DOB VIOLATION - ACTIVE |
| Jul 11, 2007 | CONSTRUCTION #0701V | DOB VIOLATION - ACTIVE |
| Oct 1, 2005 | LOCAL LAW 10/81 - ELEVATOR #04418 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Oct 29, 2026 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2025 Cat1 Test Affirmation of Correction | Active |
| Oct 29, 2026 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2025 Periodic Inspection Affirmation of Correction | Active |
| Oct 29, 2026 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2025 Periodic Inspection Affirmation of Correction | Active |
| Oct 29, 2026 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2025 Cat1 Test Affirmation of Correction | Active |
| Dec 11, 2024 | AEUHAZ FTC-AEU-HAZ | Active |
| May 2, 2024 | Benchmarking - LL84 FTF-EN-BENCH | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2020 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2021 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2020 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2021 Cat1 Test Affirmation of Correction | Active |
| Oct 2, 2023 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2022 Periodic Inspection Affirmation of Correction | Active |
| Oct 2, 2023 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2022 Periodic Inspection Affirmation of Correction | Active |
| Jun 20, 2023 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Jun 20, 2023 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Aug 2, 2020 | Benchmarking - LL84 FTF-EN-BENCH | Active |
| May 2, 2020 | Benchmarking - LL84 FTF-EN-BENCH | Active |
| Apr 6, 2018 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2016 INSPECTION REPORT | Active |
| Nov 14, 2016 | Elevators ACC1 | Active |
| Nov 14, 2016 | Elevators ACC1 | Active |
| Jun 3, 2013 | Benchmarking - LL84 FTF-EN-BENCH | Active |
| Jan 1, 2012 | Benchmarking - LL84 FTF-EN-BENCH | Active |
| Dec 31, 2009 | Boiler LBLVIO | Active |
| Oct 1, 2005 | Elevators LL1081 | Active |
| Oct 1, 2005 | Elevators LL1081 | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Jul 20, 2026 | B | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH SET AT 1ST FIRE DOOR LEADING TO LAUNDRY ROOM AT EAST WALL AT PUBLIC HALL, CELLAR ENTRANCE STORY | Aug 24, 2026 |
| Jul 20, 2026 | B | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH SET AT 2ND FIRE DOOR LEADING TO LAUNDRY ROOM AT EAST WALL AT PUBLIC HALL, CELLAR ENTRANCE STORY | Aug 24, 2026 |
| Jun 29, 2026 | C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCH IN THE ENTRANCE LOCATED AT COMPACTOR CLOSET AT PUBLIC HALL, 6th STORY, SECTION ''K-V'', AT SOUTH | Jul 13, 2026 |
| Jun 29, 2026 | C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE DOOR AND FRAME AT FIRE STAIRS EXIT DOOR AT PUBLIC HALL AT BASEMENT, SECTION AT NORTHEAST | Jul 13, 2026 |
| Jun 29, 2026 | C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE DOOR AND FRAME AT 1ST FIRE DOOR FROM PUBLIC HALL AT EAST LEADING TO LAUNDRY ROOM ( ENTRANCE STORY) AT CELLAR, SECTION ''K-V'', AT SOUTH | Jul 13, 2026 |
| Jun 29, 2026 | C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT 2ND FIRE DOOR FROM PUBLIC HALL AT EAST LEADING TO LAUNDRY ROOM ( ENTRANCE STORY) AT CELLAR, SECTION ''K-V'', AT SOUTH | Jul 13, 2026 |
| Jun 18, 2026 | C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES ON LAUNDRY ROOM DOOR BASEMENT STORY AT PUBLIC HALL | Jul 2, 2026 |
| Jun 4, 2026 | B | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES CONSISTING OF FLOWER POTS AT 5TH STORY BALCONY AT 1ST STACK FROM WEST AT NORTH AT INNER COURT AT FIRE ESCAPE | Jul 9, 2026 |
| Jun 4, 2026 | B | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH SET AT 1ST FIRE DOOR LEADING TO LAUNDRY ROOM AT EAST WALL AT PUBLIC HALL, CELLAR ENTRANCE STORY | Jul 9, 2026 |
| Jun 4, 2026 | B | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH SET AT 2ND FIRE DOOR LEADING TO LAUNDRY ROOM AT EAST WALL AT PUBLIC HALL, CELLAR ENTRANCE STORY | Jul 9, 2026 |
| Jun 4, 2026 | B | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH SET AT 1ST FIRE DOOR FROM SOUTH AT WEST LEADING TO FIRE STAIRS AT PUBLIC HALL, CELLAR ENTRANCE STORY | Jul 9, 2026 |
| Jun 1, 2026 | C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCH SET ON DOOR AT COMPACTOR CLOSET, 6th STORY, SECTION ''''SOUTH'''' | Jun 15, 2026 |
| Dec 22, 2025 | B | Apt L2 · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT BSMT-APT L2, 1st BSMT-APT FROM WEST AT NORTH | Jan 26, 2026 |
| Dec 22, 2025 | B | Apt L2 · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT BSMT-APT L2, 1st BSMT-APT FROM WEST AT NORTH | Jan 26, 2026 |
| Dec 19, 2023 | B | Apt 2N · § 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN DRAIN IN THE TERRACE LOCATED AT APT 2N, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH , SECTION ''v-m'' | Jan 23, 2024 |
| Dec 19, 2023 | B | Apt 2N · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 2nd ROOM FROM NORTH LOCATED AT APT 2N, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH , SECTION ''v-m'' | Jan 23, 2024 |
| Sep 25, 2023 | B | Apt 2N · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE IMPROPERLY COUNTERBALANCED LOWER WINDOW SASH IN THE 2nd ROOM FROM NORTH AT EAST LOCATED AT APT 2N, 2nd STORY, 2nd APARTMENT FROM NORTH AT EAST | Oct 30, 2023 |
| Sep 25, 2023 | B | Apt 2N · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 2N, 2nd STORY, 2nd APARTMENT FROM NORTH AT EAST | Oct 30, 2023 |
| Apr 10, 2023 | A | Apt LOBBY1 · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT WEST WALL INSIDE CLOSET (L1) IN THE PRIVATE HALLWAY LOCATED AT APT LOBBY1, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''NORTH'' | Jul 14, 2023 |
| Apr 10, 2023 | A | Apt LOBBY1 · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR INSIDE CLOSET (L1) IN THE PRIVATE HALLWAY LOCATED AT APT LOBBY1, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''NORTH'' | Jul 14, 2023 |
| Dec 22, 2021 | A | Apt L1 · § 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION THE HEAT RISER IN THE BATHROOM LOCATED AT CELLAR APT L1, 1st CELLAR APT FROM SOUTH AT WEST | Mar 27, 2022 |
| Dec 21, 2021 | C | Apt L1 · § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE 1st ROOM FROM NORTH LOCATED AT APT L1, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Dec 21, 2021 |
| Dec 21, 2021 | C | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM BOILER ROOM DOOR LOCKED AT BASEMENT. AT BOILER ROOM | Dec 27, 2021 |
| Dec 17, 2021 | B | Apt L2 · § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE BASE CABINET BOTTOM IN THE KITCHEN LOCATED AT BSMT-APT L2, 1st BSMT-APT FROM WEST AT NORTH | Jan 21, 2022 |
| Dec 17, 2021 | B | Apt L2 · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT BSMT-APT L2, 1st BSMT-APT FROM WEST AT NORTH | Jan 21, 2022 |
| Dec 17, 2021 | B | Apt L2 · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD MOULDING AT THE NORTH AND WEST WALL IN THE 2nd ROOM FROM EAST LOCATED AT BSMT-APT L2, 1st BSMT-APT FROM WEST AT NORTH | Jan 21, 2022 |
| Dec 17, 2021 | A | Apt L2 · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL WALLS IN THE 2nd ROOM FROM EAST LOCATED AT BSMT-APT L2, 1st BSMT-APT FROM WEST AT NORTH | Mar 22, 2022 |
| Dec 17, 2021 | B | Apt L2 · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT BSMT-APT L2, 1st BSMT-APT FROM WEST AT NORTH | Jan 21, 2022 |
| Jan 17, 2019 | A | § 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. AT PUBLIC HALL, 1st STORY | Apr 22, 2019 |
| Jan 17, 2019 | C | § 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING A DOUBLE CYLINDER KEY OPERATED LOCK INSTALLED AT THE DOOR OF BUILDING ENTRANCE. | Jan 25, 2019 |
| Jan 17, 2019 | A | § 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED AT PUBLIC HALL, 1st STORY | Apr 22, 2019 |
| Jan 17, 2019 | A | § 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE BUILDING. AT PUBLIC HALL, 1st STORY | Apr 22, 2019 |
| Date | Source | What | Now |
|---|---|---|---|
| Oct 29, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Cat1 Test Affirmation of Correction | Open |
| Oct 29, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Periodic Inspection Affirmation of Correction | Open |
| Oct 29, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Periodic Inspection Affirmation of Correction | Open |
| Oct 29, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Cat1 Test Affirmation of Correction | Open |