Bronx · Block 2857 · Lot 71 · 10452

1430 Inwood Avenue

3 floors · 28,000 sq ft · built 1928 · class G9 · owner of record: 1430 Inwood Llc

56open violations
$8,750ECB/OATH penalties owed
0HPD class C (immediately hazardous)
43dto Gas piping inspection (2026 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 4 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 43 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 43 days
Keep the report on file (not filed with DOB)
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 28,000 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 164 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 164 days
Annual filing
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-03-12 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (19) · $8,750 owed
IssuedViolationHearingBalance
Apr 1, 2026Construction CLASS - 1
JOB NUMBER 201081239 PERMIT ISSUED HOWEVER NO CERTIFICATE OF OCCUPANCY-CURRENT DOB CERTIFICATE OF OCCUPANCY NUMBER X000069330 HAS PARKING GARAGE ON FIRST FLOOR ONLY. CAR PARKING OBSERVED AT ALL THREE FLOORS AND
#39182770J
Nov 20, 2026
PENDING
$6,250
Oct 1, 2024Construction CLASS - 1
FAILURE TO SUBMIT THE REQUIRED PARKING STRUCTURE INITIAL OBSERVATION REPORT FOR AN EXISTING PARKING STRUCTURE DOCUMENTING THE CONDITIONS OF PSID#X0000398 BY THE AUGUST 1, 2024 DEADLINE. TO DATE, THE DEPARTMENT
#37029586X
Mar 7, 2025
IN VIOLATION
$2,500
May 9, 2023Construction CLASS - 1
ALTERED/CHANGED BUILDING OCCUPIED WITHOUT A VALID C OF O AS PER 28- 118.3.1 - 28-118.3.2. OBSERVED CELLAR LEVEL OCCUPIED AS PARKING GARAGE WITH 24 VEHICLES, BASEMENT LEVEL AS OFFICE SPACES & SHOWROOM WITH 2 VEH
#39085926M
Aug 18, 2023
IN VIOLATION
$0
May 9, 2023Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. AT TIME OF INSPECTION OBSERVED AT CELLAR LEVEL PARKING GARAGE STAIRWELL CEILING ABOVE LANDING, AREA APPROX. 6SQFT OF SPALLED CONCRETE AND EXPOSED REBAR. AT
#39085927Y
Aug 18, 2023
IN VIOLATION
$0
Sep 9, 2021Construction CLASS - 1
ALTERED/CHANGED BUILDING OCCUPIED WITHOUT A VALID C/O.NOTE:A BUILDING OCCUPIED WITHOUT A SIGN OFF TO JOB 201081239 AND TO CO.THE BUILDING HAS VEHICLE STORAGE PARKING A BODY SHOP.REM:OBTAIN A VALID CO OR DISCONT
#35581235K
May 20, 2022
IN VIOLATION
$0
Dec 15, 2011Construction CLASS - 1
FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGE WAY. NOTED : @ GARAGE CELLAR LEVEL EMERGENCY EXIT DOOR AT LEFT IS OBSTRUCTED W/ TIGHT FITTING PARKED CARS. REMEDY : REMOVE OBSTRUCTION, MAINTAIN EXIT PASSAGEWAY CLEA
#34932711H
Feb 3, 2012
IN VIOLATION
$0
Dec 15, 2011Construction CLASS - 1
ALTERED / CHANGED BLDG OCCUPIED W/O A VALID CERTIFICATE OF OCCUPANCY AS PER 28-118.3.1 - 28 - 118.3.2 NOTED : BLDG CHARGED UNDER ALTERATION TYPE 1 # 201081239 & OCCUPIED @ CELLAR, 1ST FL & 2ND FL W/ GARAGE, SHO
#34932712J
Feb 3, 2012
IN VIOLATION
$0
Dec 12, 2008Construction CLASS - 1
WORK WITHOUT PERMIT. WITNESSED BURNHAM HEATING BOILER INSTALLED ON THE1ST FLOOR ON COMMERCIAL PROPERTY. NO PERMITS WERE FILED FOR THIS JOB, ALSO HIGH LIMIT AQUASTAT IS NOTWIRED SAFETY VALVE DISCHARGE NOT PIPED
#34738253K
Jan 15, 2010
IN VIOLATION
$0
Dec 12, 2008Construction CLASS - 1
FAILURE TO PROVIDE PROTECTION AT SIDES OF EXCAVATION. NOTED: EXCAVATION WORK WAS DONE & NO SHORING WAS INSTALLED. THE EXCAVATED AREAS ARE APPROX. 12' DEEP. THE STRUCTURAL COLUMNS ARE BEING EXTENDED & THE
#34735691R
Feb 6, 2009
IN VIOLATION
$0
Dec 12, 2008Construction CLASS - 2
FAILURE TO PROVIDE APPROVED/ACCEPTABLE PLANS AT JOB SITE AT TIME OF INSPECTION. NOTED: EXCAVATION AND STRUCTURAL WORK WAS BEING DONE W/O APPROVED PLANS AT JOB SITE. THE CONTRACTOR WAS NOT ABLE TO PROVIDE
#34735692Z
Feb 6, 2009
IN VIOLATION
$0
Dec 12, 2008Construction CLASS - 1
FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS. NOTED: THE CONSTRUCTION SITE HAS NO WARNING OR DANGER SIGNSPOSTED. THERE IS NO CONSTRUCTION FENCING. THE SITE IS OPEN TO PUBLIC
#34735693K
Feb 6, 2009
IN VIOLATION
$0
Dec 12, 2008Construction CLASS - 2
FAILURE TO SAFEGUARD ALL PERSONS AFFECTED BY CONSTRUCTION OPERATIONS. NOTED: "NO SMOKING" SIGNS W/I CONSTRUCTION SITE OBSERVED,IN VIOLATION IF NYC FIRE CODE 1404.1 & FC310. REMEDY: SAFEGUARD PUBLIC & PROPERTY
#34735694M
Feb 6, 2009
IN VIOLATION
$0
Dec 12, 2008Unknown CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE COMPLAINT MANNER WITNESSED GAS VALVED FUTURE CONNECTION ON THE 1ST FLOOR IN LAUNDRY ROOM. ALSO GAS SPACE HEATER INSTALLED IN THE CELLAR WITHOUT SUT OFF VALVE. REM: CAP AND R
#34738254M
Feb 6, 2009
IN VIOLATION
$0
Aug 17, 2006Construction Hazardous
FAILURE TO MAINTAIN. NOTED: CONCRETE SLAB (CEILING) INDERSIDE OF 1ST FL & 2ND FL IS SPALLING W/ MISSING SECTIONS, EXPOSING REBARS, SUPPORTEDBEAMS ARE CORRODED. REMEDY: MAKE ALL NECESSARY REPAIRS.
#34535040R
Nov 3, 2006
IN VIOLATION
$0
Aug 17, 2006Construction Hazardous
EXIT DOOR: TOTAL OBSTRUCTION. NOTED: AT SECOND FL STAIRWAY EXIT DOOR IS OBSTRUCTED BY A PARKED VEHICLE, EXIT DOOR REQUIRED AS A MEAN OF EGR ESS. REMEDY: REMOVE OBSTRUCTION.
#34535041Z
Nov 3, 2006
IN VIOLATION
$0
Apr 21, 2006Construction Hazardous
FAILURE TO MAINTAIN.NOTE:CONCRETE SLAB (CEILING) INDERSIDE OF THE 1ST FL IS SPALLING WITH A MISSING SECTION, THUS EXPOSING THE REBARS (REINFORCING RODS) IN SAID AREA.REMEDY:MAKE ALL NECESSARY REPAIRS
#34517402X
Jul 7, 2006
IN VIOLATION
$0
Dec 29, 2005Construction Hazardous
FAILURE TO MAINTAIN. AT BASEMENT, CONCRETE SLAB (CEILING) FOR 1ST FLR HAS SPALLING, MISSING CONCRETE EXPOSING METAL REBAR A = 2' X 2' SECTION TOWARDS THE CENTER OF GARAGE. REMEDY: MAKE ALL NECESSARY REPAIRS.
#34505249K
Jul 7, 2006
IN VIOLATION
$0
Dec 29, 2005Construction Non-Hazardous
OCCUPANCY CONTRARY TO THAT ALLOWED BY THE CERTIFICATE OF OCCUPANCY CO # 69330 INDICATES THAT AT BASEMENT LEGAL USE IS A AUTO REPAIR (USE GROUP (6) BASEMENT IS NOW A PUBLIC PARKING GARAGE (USE GROUP #8) WITH 75
#34505248Z
Jul 7, 2006
IN VIOLATION
$0
Dec 29, 2005Construction Non-Hazardous
FAILURE TO POST CERTIFICATE OF OCCUPANCY. REMEDY: POST CERTIFICATE OF OCCUPANCY.
#34505247R
Jul 7, 2006
IN VIOLATION
$0
DOB (18)
IssuedViolationStatus
Jun 20, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION
#29227
DOB VIOLATION - ACTIVE
Feb 2, 2022FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#00210
DOB VIOLATION - ACTIVE
Dec 1, 2021FAILURE TO POST ENERGY GRADE/SCORE
FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3
#2101516
DOB VIOLATION - ACTIVE
Nov 2, 2021FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#00288
DOB VIOLATION - ACTIVE
Aug 2, 2021FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#00421
DOB VIOLATION - ACTIVE
Jun 2, 2021FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#00663
DOB VIOLATION - ACTIVE
Apr 29, 2021FAILURE TO POST ENERGY GRADE/SCORE
FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3
#2002036
DOB VIOLATION - ACTIVE
Feb 2, 2021FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#00232
DOB VIOLATION - ACTIVE
Nov 2, 2020FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#00304
DOB VIOLATION - ACTIVE
Aug 2, 2020FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#00577
DOB VIOLATION - ACTIVE
May 2, 2020FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#00577
DOB VIOLATION - ACTIVE
Feb 2, 2020FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#00338
DOB VIOLATION - ACTIVE
Nov 2, 2019FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#00457
DOB VIOLATION - ACTIVE
Aug 2, 2019FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#00712
DOB VIOLATION - ACTIVE
May 2, 2019FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#01351
DOB VIOLATION - ACTIVE
Apr 6, 2018LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2016 INSPECTION REPORT
#06667
DOB VIOLATION - ACTIVE
Mar 7, 2012FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00103
DOB VIOLATION - ACTIVE
Mar 7, 2012FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00104
DOB VIOLATION - ACTIVE
DOB NOW Safety (19)
IssuedViolationStatus
Oct 31, 2025Gas Piping - LL152 FTF-PL-PER
Cycle 1, Sub-cycle C (premises is in Community District 4)
Active
Jun 20, 2023Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION
Active
Feb 2, 2022Benchmarking - LL84 FTF-EN-BENCH
Active
Dec 1, 2021Energy Grade - LL33 FTP-EN-EGRDEA
Active
Nov 2, 2021Benchmarking - LL84 FTF-EN-BENCH
Active
Aug 2, 2021Benchmarking - LL84 FTF-EN-BENCH
Active
Jun 2, 2021Benchmarking - LL84 FTF-EN-BENCH
Active
Apr 29, 2021Energy Grade - LL33 FTP-EN-EGRDEA
Active
Feb 2, 2021Benchmarking - LL84 FTF-EN-BENCH
Active
Nov 2, 2020Benchmarking - LL84 FTF-EN-BENCH
Active
Aug 2, 2020Benchmarking - LL84 FTF-EN-BENCH
Active
May 2, 2020Benchmarking - LL84 FTF-EN-BENCH
Active
Feb 2, 2020Benchmarking - LL84 FTF-EN-BENCH
Active
Nov 2, 2019Benchmarking - LL84 FTF-EN-BENCH
Active
Aug 2, 2019Benchmarking - LL84 FTF-EN-BENCH
Active
May 2, 2019Benchmarking - LL84 FTF-EN-BENCH
Active
Apr 6, 2018Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2016 INSPECTION REPORT
Active
Mar 7, 2012AEUHAZ FTC-AEU-HAZ
Active
Mar 7, 2012AEUHAZ FTC-AEU-HAZ
Active
HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 17, 2026, 12:01 PM ET. BBL 2028570071.