Queens · Block 5048 · Lot 7505 · 11355

143-16 41 Avenue

8 floors · 34 apartments · 26,871 sq ft · built 2020 · class RM · owner of record: Ying City Plaza Corp

18open violations
$8,870ECB/OATH penalties owed
2HPD class C (immediately hazardous)
62dto Bedbug annual filing

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 62 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 62 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 78 days
Annual
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 26,871 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 183 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 183 days
Annual filing
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 306 days
Registered through 2027-09-01
Facade inspection report (Cycle 10B) Applies
Local Law 11 / FISP · Feb 21, 2026 to Feb 21, 2028
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 0, 7 or 8 are in sub-cycle 10B. Agency page

Feb 21, 2028
in 479 days
No Cycle 10 report on record yet
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 7 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1158 days
Next cycle year 2029
Annual boiler inspection (34 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-03-26 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (4) · $8,870 owed
IssuedViolationHearingBalance
Jul 15, 2026Construction CLASS - 1
WORK WITHOUT A PERMIT. ILLEGAL PLUMBING WORK NOTED AT 1ST FLOOR LEFT REAR(CF2) HAVING INSTALLED WASTE AND WATER LINES AND DRAIN FOR SHOWER AMD WASHER AND DRYER COMBO. REMEDY: OBTAIN ALL PERMITS.
#35729211Y
Sep 22, 2026
DEFAULT
$2,530
Jul 15, 2026Unknown CLASS - 1
ELECTRICAL WORK WITHOUT A PERMIT. ILLEGAL WORK NOTED AT 1ST FLOOR LEFTREAR(CF2) HAVING INSTALLED WIRING FOR 220VLT OUTLET FOR WASHER-DRYER COMBO. REMEDY: OBTAIN ALL PERMITS.
#35729212X
Sep 22, 2026
DEFAULT
$2,530
Jul 15, 2026Construction CLASS - 1
WORK WITHOUT A PERMIT. ILLEGAL CONSTRUCTION WORK NOTED AT 1ST FLOOR LEFT REAR(CF2) HAVING ERECTED FULL HEIGHT PARTITIONS TO CREATE MASSAGE ROOMS AND 3PCS BATHROOM WITH LAUNDRY. REMEDY: OBTAIN ALL PERMITS.
#35729210M
Sep 22, 2026
DEFAULT
$2,530
Jul 15, 2026Construction CLASS - 2
ILLEGAL USE IN A RESIDENTIAL DISTRICT. UNLICENSED PHYSICAL TREATMENT ESTABLISHMENT IS OPERATING IN A R7-1 DISTRICT ON 1ST FLOOR REAR LEFT(CF2). A PROHIBITED USE AS PER ZR12-10. NOTED: DOING BUSINESS AS "WARMTON
#35729209P
Sep 22, 2026
DEFAULT
$1,280
DOB (0)

None open.

DOB NOW Safety (0)

None open.

HPD (14) · C 2 · B 10 · A 2
IssuedClassViolationCorrect by
Apr 27, 2009BApt 2C · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 2C, 1st STORY, 1st APARTMENT FROM WEST AT NORTHJun 1, 2009
Apr 27, 2009BApt 2C · § 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 2C, 1st STORY, 1st APARTMENT FROM WEST AT NORTHJun 1, 2009
Apr 27, 2009A§ 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN A PRIVATE DWELLING. AT PUBLIC HALL, 1st STORYJul 31, 2009
Jul 7, 2008BApt 2C · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 2C, 1st STORY, 1st APARTMENT FROM WEST AT NORTHAug 11, 2008
Jul 7, 2008BApt 2C · § 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 2C, 1st STORY, 1st APARTMENT FROM WEST AT NORTHAug 11, 2008
Feb 1, 2007BApt 2B · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 2B, 1st STORY, APARTMENT AT EASTMar 13, 2007
Feb 1, 2007BApt 2B · § 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 2B, 1st STORY, APARTMENT AT EASTMar 13, 2007
Feb 1, 2007C§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR TO BOILER ROOM LOCKED AT CELLARFeb 12, 2007
Feb 1, 2007B§ 27-2040 ADM CODE PROVIDE ADEQUATE LIGHTING AT OR NEAR THE OUTSIDE OF THE FRONT ENTRANCEWAY OF THE BUILDING AND KEEP SAME BURNING FROM SUNSET EVERY DAY TO SUNRISE ON THE DAY FOLLOWING 100 WATTS MINIMUNMar 13, 2007
May 11, 2005B§ 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE NORTH COURTJun 20, 2005
Mar 7, 2003BApt 2B · § 27-2026 ADM CODE REPAIR THE FLUSHING APPARATUS AND MAINTAIN SAME SO AS TO FLUSH EFFECTIVELY THE WATER CLOSET ... IN THE BATHROOM LOCATED AT APT 2B, 1st STORYApr 16, 2003
Jul 16, 2002B§ 27-2053 ADM CODE PROVIDE DWELLING WITH A JANITOR OR RESPONSIBLE PERSON OR JANITORIAL SERVICE.Aug 25, 2002
Jul 16, 2002A§ 27-2053 ADM CODE POST SIGN ON WALL OF ENTRANCE STORY BEARING NAME, ADDRESS INCLUDING APARTMENT NUMBER IF ANY, AND TELEPHONE NUMBER OF SUPERINTENDENT, JANITOR OR HOUSEKEEPER. AT PUBLIC HALLOct 24, 2002
Mar 30, 1999C§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED CELLAR.Apr 19, 1999

Issued in the last 120 days

DateSourceWhatNow
Jul 15, 2026ECBConstruction: WORK WITHOUT A PERMIT. ILLEGAL PLUMBING WORK NOTED AT 1ST FLOOR LEFT REAR(CF2) HAVING INSTALLED WASTE AND WATER LINES AND DRAIN FOR SHOWER AMD WASHER AND DRYER COMBO. REMEDY: OBTAIN ALL PERMITS.Open
Jul 15, 2026ECBUnknown: ELECTRICAL WORK WITHOUT A PERMIT. ILLEGAL WORK NOTED AT 1ST FLOOR LEFTREAR(CF2) HAVING INSTALLED WIRING FOR 220VLT OUTLET FOR WASHER-DRYER COMBO. REMEDY: OBTAIN ALL PERMITS.Open
Jul 15, 2026ECBConstruction: WORK WITHOUT A PERMIT. ILLEGAL CONSTRUCTION WORK NOTED AT 1ST FLOOR LEFT REAR(CF2) HAVING ERECTED FULL HEIGHT PARTITIONS TO CREATE MASSAGE ROOMS AND 3PCS BATHROOM WITH LAUNDRY. REMEDY: OBTAIN ALL PERMITS.Open
Jul 15, 2026ECBConstruction: ILLEGAL USE IN A RESIDENTIAL DISTRICT. UNLICENSED PHYSICAL TREATMENT ESTABLISHMENT IS OPERATING IN A R7-1 DISTRICT ON 1ST FLOOR REAR LEFT(CF2). A PROHIBITED USE AS PER ZR12-10. NOTED: DOING BUSINESS AS "WARMTONOpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 30, 2026, 9:28 PM ET. BBL 4050487505.

Look up another building