Queens · Block 5195 · Lot 69 · 11355

143-07 45 Avenue

5 floors · 14,787 sq ft · built 2014 · class M1 · owner of record: Boon Church Of Overseas Chinese Mission, Inc

25open violations
$73,540ECB/OATH penalties owed
0HPD class C (immediately hazardous)
1159dto Gas piping inspection (2029 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 63 days
Keep the report on file (not filed with DOB)
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 7 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1159 days
Next cycle year 2029

Open violations

ECB / OATH (25) · $73,540 owed
IssuedViolationHearingBalance
Oct 24, 2026Construction CLASS - 2
OBSERVED SIDEWALK SHED PERMIT Q00567469-I1-SH EXPIRED ON 10/15/26. SWSMISSING MAINTENANCE AND LEGAL SUPERVISION INCREASED THE RISK FOR PEDESTRIANS AND PUBLIC. , MAINTAIN SIDEWALK SHED
#39561022Y
Dec 29, 2026
PENDING
$1,250
Oct 13, 2026Construction CLASS - 2
AT TIME OF INSPECTION OBSERVED A DIESEL FUEL GENERATOR @ 1ST FLOOR WITHOUT THE REQUIRED FDNY PERMIT FOR THE USE OF THE GENERATOR. STOP ALL USE OF DIESEL FUEL GENERATOR.
#39560480R
Dec 22, 2026
PENDING
$1,250
Oct 2, 2026Construction CLASS - 2
AT INSPECTION OF A 2-STORY BUILDING, NO ACTIVE CONSTRUCTION WORK WAS OBSERVED, HOWEVER A CONSTRUCTION FENCE WAS IN PLACE. DEPARTMENT RECORDSINDICATE FENCE PERMIT Q01245952-S2-FN EXPIRED 07/15/2026. THE EXPIRED
#39560080H
Dec 8, 2026
PENDING
$1,250
Aug 20, 2026Unknown CLASS - 2
3305.1; OBS ACTIVE 3 STORY NB WITH CONS FENCE & SWS INSTALLED @ EXPO 1. @ EXPO 1, ON 3RD FLOOR, A WORKER WAS SEEN WORKING ON TOP OF BAKER SCAFFOLD WITH NO FALL PROTECTION OR PPE WHILE WORKING ALONG THE EDGE ON
#39558184J
Oct 27, 2026
PENDING
$2,500
Aug 20, 2026Construction CLASS - 2
OBS ACTIVE 3 STORY NB WITH CONS FENCE & SWS INSTALLED @ EXPO 1. UPON REVIEWING THE SWS PLANS, PLANS CALL FOR ALL BAYS OF SWS TO HAVE CROSS BRACING, ONSITE CONDITIONS DO NOT REFLECT SWS DRAWINGS. 5' EXTENSION OF
#39558180M
Oct 27, 2026
PENDING
$1,250
Apr 24, 2026Unknown CLASS - 2
BC3303.7.2 OBSERVED ACTIVE SITE UPON INSPECTION NOTED INADEQUATE FIRE EXTINGUISHERS ON SOME FLOORS MISSING TAGS AND DELIVER DATE , SUPER MONTLY INSPECTION , ALSO NOTED IT MISSING ON CELLAR AND ROOF LEVEL CONT
#39553432R
Jun 30, 2026
DEFAULT
$5,000
Apr 24, 2026Unknown CLASS - 2
BC3301.1 OBSERVED ACTIVE SITE UPON ISPECTION NOTED ON EXPOSURE 3 CMU WORK WAS STARTED AND REINFORCING REBAR PLACED , WORK HAS BEEN STOPED AND REBAR NEVER WAS CAPED AS PER OSAH 1926.701(B) REQUIRE ,CREATING HAZ
#39553433Z
Jun 30, 2026
DEFAULT
$5,000
Jan 31, 2026Unknown CLASS - 1
AT TIME OF INSPECTION OBSERVED JOB SITE CLOSED. ELECTRICAL LIGHT INSTALLED UNDER SIDEWALK SHED WITHOUT A PERMIT AS REQUIRED. OBTAIN ELECTRICAL PERMIT FOR SIDEWALK SHED. OBTAIN ELECTRICAL PERMIT FOR SIDEWALK SHE
#39549720J
Mar 8, 2027
DEFAULT
$6,250
Nov 6, 2025Unknown CLASS - 2
BC3309.10 ROOF PROTECTION: DURING INSPECTION OF AN ACTIVE SITE 3 STORIES HIGH, I OBSERVED THAT THERE WAS MISSING ROOF PROTECTION OVER THE HVAC UNITS ON THE ROOF AT EX#2 ALL EQUIPMENT ON THE ROOF MUST BE PROTEC
#39546739X
Dec 29, 2026
DEFAULT
$2,530
Nov 6, 2025Unknown CLASS - 2
BC3314.1 SCOPE SCAFFOLD: DURING INSPECTION OF AN ACTIVE SITE, I OBSERVED SUPPORTED SCAFFOLD ON THE INTERIOR AT EX#2 IN FRONT OF A INCOMPLETE CMU WALL WITH BLOCKS ON PLANKS. THE SCAFFOLD WAS MISSING GUARDRAILS,
#39546740N
Dec 29, 2026
DEFAULT
$2,530
Nov 6, 2025Construction CLASS - 2
BC3309.4.3 PRECONSTRUCTION SURVEY: DURING INSPECTION OF A 3 STORY BUILDING, I OBSERVED A CHIMNEY AT EXPOSURE #2 THAT WAS CRACKED/MISSING MORTAR AND DISLODGED FROM THE FACADE WITH POTENTIAL OF FALLING. I REQUEST
#39546741P
Apr 28, 2026
IN VIOLATION
$1,250
Nov 6, 2025Construction CLASS - 1
2113.1.6.1CHIMNEY RESPONSIBILITY OF OWNER OF TALLER BUILDING: ACTIVE 3 STORY SITE ADJACENT TO A BUILDING WITH A CHIMNEY STACK AT EXPOSURE #2 I OBSERVED THAT THE CHIMNEY HAD NOT BEEN EXTENDED WHICH IS REQUIRED W
#39546754Y
Apr 28, 2026
IN VIOLATION
$0
Oct 30, 2025Unknown CLASS - 2
BC 3308.5 AT TIME OF INSPECTION OBSERVED LOOSE VERTICAL DEBRIS NETTING AT EXPOSURE 1 AND 4 THIS CREATES UNSAFE CONDITIONS TO PUBLIC AND PROPERTY BY NOT PROTECTING AGAINST FALLING OBJECTS.MAINTAIN NETTING AT ALL
#39546519Y
Dec 29, 2026
DEFAULT
$2,530
Sep 19, 2025Construction CLASS - 2
AT TIME OF INSPECTION I OBSERVED EXPOSED WIRING & LIGHTING UNDER THE SIDEWALK SHED NOT ENCLOSED IN WATER-RESISTANT & VANDAL-RESISTANT FIXTURES, & ALL LAMPS, WIRING, AND ACCESSORY COMPONENTS SHALL CONFORM TO THE
#39545112H
Sep 3, 2026
IN VIOLATION
$2,400
May 19, 2025Construction CLASS - 2
SIDEWALK SHED.@3STOYR NB SITE IN STRUCTURE PHASE OBSERVE TALL SECTIONS OF SHED BY SITES GATES VERTICAL MEMBER ALL MISSING DISPLACEMENT PROTECTION(HIGH VISIBILITY MARKING/BRACE)&ARE DISPLACED&NOT PLUMB WITH DIST
#39540400J
Mar 16, 2027
PENDING
$10,000
May 19, 2025Construction CLASS - 1
SIDEWALK SHED.@3STORY NB SITE IN STRUCTURE PHASE OBSERVE PERMITTED SIDEWALK SHED JOB#Q00567469 IN PLACE NOT CONFORM TO PLANS-ADDITIONAL TALL SHED SECTION IN MIDDLE OF EXP#1 NOT ON PLAN,TALL SECTION MISSING VERT
#39540399L
Mar 16, 2027
PENDING
$12,500
Dec 13, 2023Construction CLASS - 1
BC 1704.1.4.2 FAILURE TO PERFORMING SPECIAL INSPECTION DUTIES AND RESPONSIBILITIES: UPON CEU'S STRCUTURAL AUDIT IT WAS OBSERVED THAT THE SPECIAL INSPECTION AGENCY, AA BUILDING AND INSPECTION(LICENSE #001519) PE
#35538144L
Mar 25, 2025
IN VIOLATION
$2,500
Sep 22, 2023Construction CLASS - 2
WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND/OR AMENDMENTS.AS NOTED:AT TIME OF INSPECTION ON ACTIVE CONSTRUCTION SITE 3 STORY WITH MEZZANINE STEEL STRUCTURE BUILDING ERECTED TO ROOF LEVEL.OBSERV
#35674295P
Nov 28, 2023
DEFAULT
$6,250
Aug 22, 2023Construction CLASS - 2
AT INSPECTION, IT WAS OBSERVED: SIDEWALK SHED AT EXPOSURE-1 WAS NOT TIGHT TO FACADE OR SEALED AS PER 3307.6.4.5 THEREBY EXPOSING PUBLIC USING SIDEWALK TO DANGER OF BEING STRUCK FROM ABOVE, ALSO NO REFLECTIVE PA
#39520853Y
May 14, 2024
IN VIOLATION
$2,400
May 8, 2023Construction CLASS - 1
INADEQUATE PROTECTION FOR ADJOINING PROPERTY SPACE.@3 STORY NB SITE I OBSERVE STEEL STRUCTURE PHASE UP TO 3RD FLOOR LEVEL TOWERING OVER ADJOIN PROPERTY @EXPOSURE#3 (43-63 BOWNE ST) WITH MISSING OVERHEAD PROTECT
#39516296Z
Mar 24, 2025
IN VIOLATION
$2,500
Dec 30, 2021Construction CLASS - 2
PEDESTRIAN PROTECTION SIDEWLAK SHED UNSAFE/NOT MEET CODES.AT TIME OF INSPECTION AN ACTIVE NB PERMIT SITE I OBSERVED SIDEWALK SHED IN PLACE NOT CONSTRUCTED PER CODES AND UNSAFE WITH PEDESTRIAN PASSING BELOW SHED
#35637035X
Mar 31, 2025
IN VIOLATION
$2,400
Apr 24, 2017Construction CLASS - 1
B106,1,BC1905.6.5. LOW STRENGTH TEST RESULT. AS NOTED: @ TIME OF INSP.FOUNDATION STAGE LOW COMPRESSIVE STRENGTH RESULT:SOUTH/EAST,WEST & NORTH FOOTINGS,FOOTING LINES A7,C7,D8,D9,ELEVATOR PIT, FOUNDATION WALLS.
#35254866Z
Jun 29, 2017
IN VIOLATION
$0
Jul 16, 2015Construction CLASS - 1
SEC. 3303.4.1 MAINTENANCE: SLIPPING & TRIPPING HAZARDS. NOTE: 5 STY BLDG UNDER CONSTRUCTION. THE SIDEWALK AT THE FRONT OF THE SITE ALONG 45 AVE. A SECTION OF THE SIDEWALK HAS BE LEFT UNEVEN,CRACKED & DAMAGED.
#35146585Y
Sep 1, 2015
WRITTEN OFF
$0
Jul 16, 2015Construction CLASS - 2
SEC. 3301.1.2 FAILURE TO COMPLY W/NYC FIRE CODE-GENERAL NO PERMIT FOR OXYGEN/ACETYLENE. NOTE: 5 STY BLDG UNDER CONSTRUCTION. AT TIME OF INSPECTION OBSERVED WORKERS USING TORCH TO DO STEEL WORK. TANKS WERE LOCAT
#35146584M
Sep 1, 2015
WRITTEN OFF
$0
Jul 16, 2015Construction CLASS - 1
FAILURE TO MAINTAIN: NO GUARDRAILS. NOTE: 5 STY BLDG UNDER CONSTRUCTION. TOWARDS THE REAR OF THE SITE OBSERVED STAIR OPENING 3FT X 8FT APPROX W/NO GUARDRAIL SYSTEM AROUND IT. AT ANOTHER LOCATION OBSERVED ANOTHE
#35146582Z
Sep 1, 2015
WRITTEN OFF
$0
DOB (1)
IssuedViolationStatus
Aug 10, 2015CONSTRUCTION

#C0701MG
DOB VIOLATION - ACTIVE
DOB NOW Safety (3)
IssuedViolationStatus
Sep 18, 2025Gas Piping - LL152 FTF-PL-PER
Cycle 1, Sub-cycle B (premises is in Community District 7)
Active
Sep 18, 2025Gas Piping - LL152 FTF-PL-PER
Cycle 1, Sub-cycle B (premises is in Community District 7)
Active
Sep 18, 2025Gas Piping - LL152 FTF-PL-PER
Cycle 1, Sub-cycle B (premises is in Community District 7)
Active
HPD (0)

None open.

Issued in the last 120 days

DateSourceWhatNow
Oct 24, 2026ECBConstruction: OBSERVED SIDEWALK SHED PERMIT Q00567469-I1-SH EXPIRED ON 10/15/26. SWSMISSING MAINTENANCE AND LEGAL SUPERVISION INCREASED THE RISK FOR PEDESTRIANS AND PUBLIC. , MAINTAIN SIDEWALK SHEDOpen
Oct 13, 2026ECBConstruction: AT TIME OF INSPECTION OBSERVED A DIESEL FUEL GENERATOR @ 1ST FLOOR WITHOUT THE REQUIRED FDNY PERMIT FOR THE USE OF THE GENERATOR. STOP ALL USE OF DIESEL FUEL GENERATOR.Open
Oct 2, 2026ECBConstruction: AT INSPECTION OF A 2-STORY BUILDING, NO ACTIVE CONSTRUCTION WORK WAS OBSERVED, HOWEVER A CONSTRUCTION FENCE WAS IN PLACE. DEPARTMENT RECORDSINDICATE FENCE PERMIT Q01245952-S2-FN EXPIRED 07/15/2026. THE EXPIREDOpen
Aug 20, 2026ECBUnknown: 3305.1; OBS ACTIVE 3 STORY NB WITH CONS FENCE & SWS INSTALLED @ EXPO 1. @ EXPO 1, ON 3RD FLOOR, A WORKER WAS SEEN WORKING ON TOP OF BAKER SCAFFOLD WITH NO FALL PROTECTION OR PPE WHILE WORKING ALONG THE EDGE ONOpen
Aug 20, 2026ECBConstruction: OBS ACTIVE 3 STORY NB WITH CONS FENCE & SWS INSTALLED @ EXPO 1. UPON REVIEWING THE SWS PLANS, PLANS CALL FOR ALL BAYS OF SWS TO HAVE CROSS BRACING, ONSITE CONDITIONS DO NOT REFLECT SWS DRAWINGS. 5' EXTENSION OFOpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 29, 2026, 9:19 AM ET. BBL 4051950069.

Look up another building