Bronx · Block 2843 · Lot 40 · 10452

1426 Townsend Avenue

5 floors · 93,205 sq ft · built 1922 · class W1 · owner of record: Nyc Department Of Education

25open violations
$0ECB/OATH penalties owed
0HPD class C (immediately hazardous)
62dto Gas piping inspection (2026 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 4 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 62 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 62 days
Keep the report on file (not filed with DOB)
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 93,205 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 183 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 183 days
Annual filing
Energy audit and retro-commissioning (2033) Likely applies
Local Law 87 · Calendar year 2033
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 2843). Agency page

Dec 31, 2033
in 2619 days
Next due 2033
Annual boiler inspection (2 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-04-07 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (12)
IssuedViolationHearingBalance
Apr 1, 2026Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: INTERIORFIRE-PROOF DOORS DO NOT CLOSE PROPERLY WHEN TESTED AT, 3RD FLR-STAIRCASE "B". 2ND FLR-STAIRCASE "C". 1ST FLR-"EXIT 3" INTERIOR GYM DOOR. REM
#35722433H
May 15, 2026
POP/IN-VIO
$0
Apr 1, 2026Construction CLASS - 2
28-301.1. RE-ISSUE #35719753J. FAILURE TO PROVIDE VENTILATION TO GAS METER PER P115.6(1968), FGC APPENDIX E(E4)(2014 CODE). NOTED: IN CELLAR, GAS METER ROOM DOES NOT HAVE PROPER VENTILATION IN THE ROOM. REMEDY:
#35722432X
May 15, 2026
POP/IN-VIO
$0
May 23, 2025Construction CLASS - 2
REISSUE #35682961H DATE OF ISSUE: 07-26-2024. FAILURE TO PROVIDE VENTILATION TO GAS METER ROOM PER 115.6(1968 CODE), FGC APPENDIX E(E6)(2014CODE) IN CELLAR GAS METER ROOM NO PROPER VENTILATION OBSERVED AT THE T
#35719753J
Jul 11, 2025
POP/IN-VIO
$0
Jul 26, 2024Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.ILLUMINATION FOREXITS,EXIT DISCHARGES AND PUBLIC CORRIDORS.NOTED:EMERGENCY EXIT SIGNS NOT ILLUMIZED AT TIME OF INSPECTION-5F NEXT TO STAIRWAY#3,4FL STAIRWAY
#35682963L
Dec 20, 2024
POP/IN-VIO
$0
Jul 26, 2024Construction CLASS - 2
28-301.1 REISSUE ECB#35623000Y FAILURE TO PROVIDE VENTILATION TO GAS METER ROOM NOTED:IN CELLAR GAS METER ROOM NOT VENTILATED PROPERLY.REM:COMPLY WITH NOTICE OF VIOLATION.
#35682961H
Dec 20, 2024
POP/IN-VIO
$0
Apr 5, 2023Construction CLASS - 2
38-301 REISSUE #35578400H FAILURE TO PROVIDE VENTILATION TO GAS METER RM PER P115.6(1968 CODE) FGC APPENDIX E(E4)(2014 CODE).NOTE:OBSERVED AT CELLAR LEVEL GAS METER RM HAS NO VENTILATION FOR FRESH AIR.REMEDY:CO
#35673000Y
Jul 7, 2023
POP/IN-VIO
$0
Mar 24, 2022Construction CLASS - 2
RE-ISSUE #35553643L FAILURE TO PROVIDE VENTILATION TO GAS METER ROOM PER P115.6(1968 CODE) FGC APPENDIX E (E4)(2014 CODE)NOTED:OBSERVED AT (CELLAR)GAS METER ROOM NO VENTILATION FOR FRESH AIR.REMEDY:COMPLY WITH
#35578400H
Jul 15, 2022
POP/IN-VIO
$0
Mar 10, 2021Construction CLASS - 2
28-301.1 REISSUE: 35235273J FAILURE TO PROVIDE VENTILATION TO GAS METER ROOM PER 115.6 (1968 CODE) FGC APPENDIX E (E4) 2014. NOTED: NO VENTILATION AT GAS METER ROOM. REMEDY: COMPLY WITH CODE
#35553643L
Jun 18, 2021
POP/IN-VIO
$0
Apr 13, 2020Construction CLASS - 2
SEC. 28-301.1 FAILURE TO PROVIDE VENTILATION TO GAS METER ROOM PER P115.6(1968 CODE),FGC APPENDIX E(E 4)(2014 CODE). NOTED: AT GAS METER ROOM,NO FRESH AIR VENTILATION PROVIDED. REMEDY: COMPLY W/NOTICE OF VIOLAT
#35490770Z
Aug 7, 2020
POP/IN-VIO
$0
Mar 20, 2019Construction CLASS - 2
28-301.1 RE-ISSUE# 35311783L FAILURE TO PROVIDE VENTILATION TO GAS METER ROOM PER P115.6(1968 CODE),FGC APPENDIX E(E4)(2014 CODE) NOTE:AT CELLAR LEVEL IN GAS METER ROOM NO FRESH AIR VENTILATION. REMEDY:COMPLY W
#35402405H
Jun 7, 2019
POP/IN-VIO
$0
Feb 6, 2018Construction CLASS - 2
28-301.1 REISSUE VIOLATION #35235273J FAILURE TO PROVIDE VENTILATION TO GAS METER ROOM PER P 115.6 (1968 CODE) FGC APPENDIX E (E4)(2014) CODE. NOTE: MISSING VENTILATION WAS OBSERVED OF GAS METER ROOM AT CEL
#35311783L
May 18, 2018
POP/IN-VIO
$0
Mar 16, 2017Construction CLASS - 2
SEC. 28-301.1 FAILUR TO PROVIDE VENTILATION TO GAS METER ROOM PER P115.6(1968 CODE),FGC APPENDIX E(E4)(2014 CODE). NOTED: MISSING VENTILATION WAS OBSERVED AT GAS METER ROOM AT CELLAR LEVEL. REMEDY: COMPLY W/NOT
#35235273J
May 5, 2017
POP/IN-VIO
$0
DOB (4)
IssuedViolationStatus
Nov 14, 2025LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
#06150
DOB VIOLATION - ACTIVE
Nov 14, 2025LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
#06149
DOB VIOLATION - ACTIVE
Jun 20, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION
#43324
DOB VIOLATION - ACTIVE
Jun 20, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION
#45355
DOB VIOLATION - ACTIVE
DOB NOW Safety (9)
IssuedViolationStatus
Nov 14, 2025Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
Active
Nov 14, 2025Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2022 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2022 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2018 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2020 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2020 External Inspection Affirmation of Correction for LP Device
Active
Jun 20, 2023Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION
Active
Jun 20, 2023Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION
Active
HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 30, 2026, 1:00 PM ET. BBL 2028430040.